USA

ORTEC (AMETEK)

Designs and manufactures ionising radiation detectors – detection hardware, nuclear measurement instruments, analysis software and complete systems.

Website

HPGe & gamma spectroscopy

21 products

Möbius Recycler
ORTEC

Möbius Recycler

HPGe detector cooling

Weight
28.58 kg empty; 51.26 kg full, excluding cryostat and detector
LN₂ hold time during power loss
Full dewar, typical detector: Streamline about 7–10 days; PopTop about 4–7 days
4 models
GEM HPGe-detektorer
ORTEC

GEM HPGe-detektorer

HPGe detectors for gamma spectroscopy

Energy range
Approximately 40 keV and above
Relative efficiency
10–150% across the model series; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.80–1.30 keV for GEM10–GEM150; model-dependent
17 models
Shallow Hole Probe
ORTEC

Shallow Hole Probe

HPGe gamma detector

Detector type
Configured with GEM, GMX, GLP, PROFILE or Safeguards HPGe
Weight
Approximately 12 lb
LN₂ holding time
Approximately 16 hours with 70 mm endcap
1 model
Dewars and Cryostats
ORTEC

Dewars and Cryostats

HPGe detector cooling

Cooling technology
Liquid nitrogen (LN₂)
Cryostat configurations
Vertical and horizontal dipstick, portable (all-position or multi-orientation Gamma Gage), down-looking, side-looking and J-type, depending on detector configuration
Dewar capacity
Gamma Gage: 1.2/3/5 L; MOD multi-orientation: 3/7 L; side-looking and down-looking: 7.5/13/30 L; dipstick cryostats: 30 L (DWR-30); shallow-hole probe: 0.7 L
43 models
Safeguards planar HPGe-detektor
ORTEC

Safeguards planar HPGe-detektor

Planar HPGe gamma detector

Detector type
Planar HPGe
Energy resolution at 122 keV
Warranted FWHM for SGD-16550P4: 550 eV at 1 kcps, 6 μs; 615 eV at 50 kcps, 1 μs
7 models
Safeguards koaxial HPGe-detektor
ORTEC

Safeguards koaxial HPGe-detektor

HPGe gamma detector

Detector type
HPGe, coaxial or semi-planar by SGD-GEM model
Energy resolution at 122 keV
FWHM maximum limits 0.61–0.80 keV at 1 kcps and optimal shaping; model-dependent
4 models
GLP plana HPGe-detektorer
ORTEC

GLP plana HPGe-detektorer

HPGe gamma detector

Energy range
Approximately 5–300 keV
Active area
Nominally 80–1,000 mm², model-dependent
Energy resolution at 122 keV
FWHM maximum limits 0.51–0.63 keV for the tabulated models
8 models
GWL brunnsdetektorer
ORTEC

GWL brunnsdetektorer

HPGe gamma detector

Detector type
P-type reverse coaxial HPGe well detector
Energy range
Approximately 10 keV–10 MeV
28 models
GAMMA-X (GMX) HPGe-detektorer
ORTEC

GAMMA-X (GMX) HPGe-detektorer

HPGe gamma detector

Energy range
Approximately 5 keV–10 MeV
Relative efficiency
10–100%; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.85–1.40 keV for GMX10–GMX100; model-dependent; optimal shaping with DSPEC-50A
12 models
PROFILE GEM HPGe-detektorer
ORTEC

PROFILE GEM HPGe-detektorer

HPGe gamma detector

Detector type
P-type HPGe; coaxial or semi-planar
Relative efficiency
Model-dependent: nominal 7–175% (GEM-M, -S, -SP); minimum 10–175% (GEM-C)
34 models
M-1 Tripod
ORTEC

M-1 Tripod

Tripod for in-situ measurements with portable HPGe spectrometers

Weight
20 lb
6 referenced values
ISO-TURNTABLE
ORTEC

ISO-TURNTABLE

Drum rotator for gamma assay of waste drums

Weight
Shipping weight 200 lb
9 referenced values
ISO-CART-II LN2
ORTEC

ISO-CART-II LN2

Mobile in-situ assay systems with LN₂-cooled HPGe detectors

Detector type
ORTEC LN₂-cooled HPGe detectors, typically large-volume GEM (p-type) or GMX (n-type); relative efficiencies over 200% available
7 referenced values
ISO-CART-II
ORTEC

ISO-CART-II

Cart for mobile in-situ gamma measurements

Weight
63.5 kg
6 referenced values
ISO-CART-85
ORTEC

ISO-CART-85

Mobile in-situ waste assay system with Stirling-cooled HPGe

Detector type
IDM-200-V: integrated very-large-area HPGe spectrometer, Stirling cooled (no liquid nitrogen)
Relative efficiency
Approx. 50% (the HPGe detector in the IDM-200-V)
9 referenced values
CSS-D-60 Compton Suppression System
ORTEC

CSS-D-60 Compton Suppression System

Compton-suppressed HPGe system for low-background counting

Detector type
N-type HPGe (GMX) with carbon-fibre endcap, max. Ø83 mm (3.25 in), and low-background Al cup
Relative efficiency
60% by default; other detector sizes up to 60% as options
9 referenced values
IDM-200-V
ORTEC

IDM-200-V

Interchangeable HPGe detector module for measurement systems

Relative efficiency
>50% typical (ANSI/IEEE 325-1996)
Energy resolution at 122 keV
≤1400 eV FWHM (warranted at optimum settings)
Energy resolution at 1.33 MeV
≤2.3 keV FWHM at 1,332 keV (warranted at optimum settings)
24 referenced values
Detective DX1-TS
ORTEC

Detective DX1-TS

Portable HPGe spectrometer for in-situ measurements

Relative efficiency
≥40% typical (ANSI/IEEE 325-1996)
Energy resolution at 122 keV
≤1630 eV FWHM (warranted at optimum settings)
Energy resolution at 1.33 MeV
≤2.0 keV FWHM at 1,332 keV (warranted at optimum settings)
22 referenced values
ACTINIDE-85 lungdetektor
ORTEC

ACTINIDE-85 lungdetektor

HPGe gamma detector

Energy range
Photon energies above 3 keV
Active front area
Over 54 cm²
Energy resolution at 122 keV
≤700 eV FWHM (warranted), at optimal shaping time with an ORTEC DSPEC-50A; consult factory for performance with ICS cooling
11 referenced values
TETRAD-20 HPGe-detektor
ORTEC

TETRAD-20 HPGe-detektor

HPGe gamma detector

Energy range
20 keV–10 MeV
Relative efficiency
TETRAD-20: 20% per detector element
Energy resolution at 122 keV
TETRAD-20: ≤1.30 keV FWHM per element
10 referenced values

Handheld & field instruments

9 products

Detective DX1
ORTEC

Detective DX1

Portable HPGe spectroscopy

Detector type
P-type coaxial HPGe detector
Energy range
DX1/DX1-N: 40 keV–3 MeV; DX1-8/DX1-8-N: 40 keV–8 MeV
Weight
7.23 kg gamma; 7.87 kg gamma/neutron
4 models
RADEAGLET-R
ORTEC

RADEAGLET-R

Handheld isotope identification

Detector type
NaI(Tl) or LaBr₃(Ce), model dependent
Energy range, NaI
NaI: 15 keV–3 MeV
Spectrum channels
2,048
12 models
RADEAGLE
ORTEC

RADEAGLE

Handheld isotope identification

Detector type
NaI(Tl) or LaBr₃(Ce), model dependent
Energy range
11 keV–3 MeV
Spectrum channels
2,048
20 models
FoodGuard-2
ORTEC

FoodGuard-2

HPGe workstation for quantitative determination of radionuclides in food

Detector type
High-resolution HPGe detector
Relative efficiency
20–60%; detector and cooling chosen when ordering
9 referenced values
FoodGuard-1
ORTEC

FoodGuard-1

NaI-based system for rapid food screening

Detector type
NaI(Tl) 3 × 3 in (ORTEC 905-4) with digiBASE: 14-pin PMT base with integrated bias supply, preamplifier and digital MCA
Typical energy resolution, Cs-137
8% at 662 keV
12 referenced values
ORTEC LABR
ORTEC

ORTEC LABR

LaBr₃(Ce) scintillation detectors with better resolution than NaI(Tl)

Detector type
LaBr₃(Ce) scintillator with 14-pin photomultiplier
Energy resolution
Per the ordering information: LABR-1x1 3.5% guaranteed; LABR-1.5x1.5 3.0% (target); LABR-2x2 and LABR-3x3 3.5% (target)
8 referenced values
ORTEC 905 Series
ORTEC

ORTEC 905 Series

NaI(Tl) scintillation detectors, 1 × 1 to 4 × 4 in

Detector type
NaI(Tl) scintillator with photomultiplier tube
Typical energy resolution, Cs-137
About 7% for a 3 in diameter by 3 in long crystal, slightly worse for larger sizes (manufacturer’s general figure for NaI(Tl))
5 referenced values
ORTEC 2BY2/3BY3
ORTEC

ORTEC 2BY2/3BY3

Integrated 2 × 2 and 3 × 3 in NaI(Tl) probes for field spectroscopy

Detector type
NaI(Tl) crystal with photomultiplier and PMT base with integral preamplifier and HV supply, in an aluminium housing
7 referenced values
INNOPROBE
ORTEC

INNOPROBE

Alpha/beta probe for the RADEAGLET-R

Detector type
Alpha/beta-sensitive scintillator with photomultiplier (ZnS:Ag)
Count-rate range
Up to 25 kcps alpha and 20 kcps beta
Weight
300 g (0.66 lb)
15 referenced values

Alpha spectrometry

29 products

RCAP-2 rekylskyddspaket
ORTEC

RCAP-2 rekylskyddspaket

Alpha spectrometry accessory

Models
RCAP-2-120V; RCAP-2-240V
Supply voltage
RCAP-2-120V: 120 V; RCAP-2-240V: 240 V
Sample-holder bias
−12 V
2 models
Alpha Suite alfaspektrometrar
ORTEC

Alpha Suite alfaspektrometrar

Integrated alpha spectrometry

Energy resolution
≤20 keV FWHM with BU-017-450-100 ULTRA detector and ²⁴¹Am point source; detector-to-source spacing equal to detector diameter
Spectrum channels
Software-selectable conversion gain: 256, 512, 1024, 2048 or 4096 channels
19 models
ORTEC C Series
ORTEC

ORTEC C Series

Annular partially depleted surface-barrier detectors

Detector type
Annular partially depleted silicon surface barrier
16 models
ORTEC B Series
ORTEC

ORTEC B Series

Totally depleted silicon surface-barrier detectors

Detector type
Totally depleted silicon surface barrier
74 models
ORTEC A Series
ORTEC

ORTEC A Series

Partially depleted silicon surface-barrier detectors

Detector type
Partially depleted silicon surface barrier
29 models
ORTEC R Series
ORTEC

ORTEC R Series

Ruggedized silicon surface-barrier detectors

49 models
ORTEC ULTRA-AS
ORTEC

ORTEC ULTRA-AS

Low-background silicon detectors for alpha spectroscopy

Detector type
Ion-implanted silicon, partially depleted
Active depth
≈100 µm
8 models
ORTEC ULTRA
ORTEC

ORTEC ULTRA

Ion-implanted silicon detectors for alpha spectroscopy

Detector type
Ion-implanted silicon, partially depleted
66 models
ORTEC F Series
ORTEC

ORTEC F Series

Partially depleted silicon surface-barrier detectors for heavy ions

Detector type
Partially depleted silicon surface barrier
Active area
100, 300, 400, 600 or 900 mm²
Depletion depth
≥60 µm, partially depleted; greater depths on special order
9 referenced values
ORTEC D Series
ORTEC

ORTEC D Series

Totally depleted silicon surface-barrier detectors for time-of-flight

Detector type
Planar, totally depleted silicon surface barrier
Active area
10, 50, 150, 300 or 450 mm² (10 mm² only at 15 µm depth); larger areas on special order
Depletion depth
Nominal 15, 25, 40, 50, 75 or 100 µm (ranges 7–15, 15.1–25, 25.1–40, 40.1–65, 65.1–85 and 85.1–110 µm)
9 referenced values
ILLUSTRATION
ORTEC

ORTEC ENS-RM-KIT

Alpha spectroscopy accessory

Function
Uninstalled rackmount kit; installed option is ordered as ENS-RACKMOUNT
Intended system
Alpha Ensemble
Ordering code
ENS-RM-KIT
4 referenced values
ILLUSTRATION
ORTEC

ORTEC MEGA-CG

Alpha spectroscopy accessory

Function
Door O-rings, pack of 5
Intended system
Alpha Mega
Ordering code
MEGA-CG
3 referenced values
ILLUSTRATION
ORTEC

ORTEC ENS-CG

Alpha spectroscopy accessory

Function
Door O-rings, pack of 10
Intended system
Alpha Aria / Duo
Ordering code
ENS-CG
3 referenced values
ILLUSTRATION
ORTEC

ORTEC RCAP-ST

Alpha spectroscopy accessory

Function
Biased sample tray assembly; includes batteries and pegs to adjust for various sample sizes
Intended system
RCAP-2 / Alpha Duo / Ensemble
Ordering code
RCAP-ST
3 referenced values
ILLUSTRATION
ORTEC

ORTEC MEGA-ST

Alpha spectroscopy accessory

Function
Sample tray up to 106 mm with spring-loaded filter retainer
Intended system
Alpha Mega
Ordering code
MEGA-ST
3 referenced values
ILLUSTRATION
ORTEC

ORTEC ENS-ST-4

Alpha spectroscopy accessory

Function
Sample tray for 1-3/4- and 2-inch samples
Intended system
Alpha Aria / Duo
Ordering code
ENS-ST-4
3 referenced values
ILLUSTRATION
ORTEC

ORTEC ENS-ST-3

Alpha spectroscopy accessory

Function
Sample tray for 1-1/4- and 1-1/2-inch samples
Intended system
Alpha Aria / Duo
Ordering code
ENS-ST-3
3 referenced values
ILLUSTRATION
ORTEC

ORTEC ENS-ST-2

Alpha spectroscopy accessory

Function
Sample tray for 1/2- and 7/8-inch samples
Intended system
Alpha Aria / Duo
Ordering code
ENS-ST-2
3 referenced values
ILLUSTRATION
ORTEC

ORTEC ENS-ST-1

Alpha spectroscopy accessory

Function
Sample tray for 3/4- and 1-inch samples
Intended system
Alpha Aria / Duo
Ordering code
ENS-ST-1
3 referenced values
ORTEC 808OPT1
ORTEC

ORTEC 808OPT1

Alpha spectroscopy accessory

Function
Vacuum hose, 4 ft
Intended system
808 / ALPHA-PPS
Ordering code
808OPT1
3 referenced values
ILLUSTRATION
ORTEC

ORTEC ALPHA-MINI-PPS-REPKIT

Alpha spectroscopy accessory

Function
Overhaul kit with diaphragm and replacement parts
Intended system
ALPHA-MINI-PPS
Ordering code
ALPHA-MINI-PPS-REPKIT
3 referenced values
ORTEC 576-VM
ORTEC

ORTEC 576-VM

Alpha spectroscopy vacuum system

Connected vacuum systems
Up to 4
Operating range
1–5000 mTorr
Valves
4 screw-type valves
8 referenced values
ORTEC ALPHA-MINI-PPS
ORTEC

ORTEC ALPHA-MINI-PPS

Alpha spectroscopy vacuum system

Pump type
Oil-free diaphragm pump
Recommended systems
One Alpha Aria or Alpha Duo
Ultimate pressure
≤2.0 mbar
10 referenced values
ORTEC ALPHA-PPS-230
ORTEC

ORTEC ALPHA-PPS-230

Alpha spectroscopy vacuum system

Pump type
Edwards RV8, two-stage rotary mechanical pump
Supply version
230 V AC
Mains frequency
50 / 60 Hz
8 referenced values
ORTEC ALPHA-PPS-115
ORTEC

ORTEC ALPHA-PPS-115

Alpha spectroscopy vacuum system

Pump type
Edwards RV8, two-stage rotary mechanical pump
Supply version
115 V AC
Mains frequency
50 / 60 Hz
8 referenced values
A-576 A-PAD alfaspektrometrikedja
ORTEC

A-576 A-PAD alfaspektrometrikedja

NIM alpha spectroscopy chain

Selectable energy ranges
3–8; 4–7; 3–5; 4–6; 5–7; 6–8 MeV
Net weight
0.9 kg
12 referenced values
ORTEC 808 vakuumkammare
ORTEC

ORTEC 808 vakuumkammare

Vacuum chamber for large samples

Net weight
4.37 kg with trays and holder
9 referenced values
ORTEC kiseldetektorer för alfaspektrometri
ORTEC

ORTEC kiseldetektorer för alfaspektrometri

Silicon detectors for alpha spectrometry

Detector type
ULTRA/ULTRA-AS: ion-implanted silicon; R: ruggedized silicon surface barrier
Depletion depth
ULTRA and R: minimum 100/300/500 µm depending on model; ULTRA-AS: approximately 100 µm
Energy resolution, example model
BU-020-450-AS: ≤20 keV FWHM at 5.486 MeV (²⁴¹Am), ORTEC electronics, 1 µs shaping; measured and warranted at 21 ±1 °C
8 referenced values

MCA, electronics & counters

106 products

digiDART
ORTEC

digiDART

Portable digital MCA

Compatible detectors
SMART-1 HPGe detectors; other detectors via a Detector Interface Module (DIM)
Spectrum channels
512–16 k
1 model
928 EASY-NIM
ORTEC

928 EASY-NIM

NIM mca, counter and timer

Spectrum channels
512–16,384, software selectable
Weight
0.9 kg net
3 models
DSPEC 50/50A & 502/502A
ORTEC

DSPEC 50/50A & 502/502A

Digital gamma spectrometer / MCA

Spectrum channels
50/502: 512–16 k; 50A/502A: 256–64 k
Weight
DSPEC 50: 11 kg; DSPEC 502: 11.7 kg
4 models
MPC-9604
ORTEC

MPC-9604

Four-detector alpha/beta counter for high sample throughput

Detector type
Four pancake-style gas-flow proportional detectors, Ø5.7 cm, with cosmic guard detector
Weight
544 kg (shipping 635 kg); the support surface must bear 1,200 lb per unit
21 referenced values
ASC-950-DP-G
ORTEC

ASC-950-DP-G

Automatic gasless alpha/beta counter with sample changer

Detector type
Dual-phosphor scintillator (ZnS + plastic), Ø5.1 cm; gasless operation
Weight
50 samples: 49.9 kg; 100 samples: 54.4 kg
14 referenced values
WPC-1150-GFW-3/GFW-5
ORTEC

WPC-1150-GFW-3/GFW-5

Automatic alpha/beta counter with a large detector for air filters

Detector type
Pancake-style gas-flow proportional detector, Ø8.9 cm (GFW-3) or Ø12.7 cm (GFW-5)
Weight
816 kg
20 referenced values
WPC-1050-GFW-2
ORTEC

WPC-1050-GFW-2

Automatic low-background alpha/beta counter, 50 or 100 samples

Detector type
Pancake-style gas-flow proportional detector, Ø5.7 cm
Weight
50 samples: 195 kg; 100 samples: 200 kg
17 referenced values
MPC-900-GFW-2/GFL-2
ORTEC

MPC-900-GFW-2/GFL-2

Manual single-sample alpha/beta counter with gas-flow detector

Detector type
Hemispherical gas-flow proportional detector, Ø5.7 cm; windowed or windowless
Weight
40 lb; shield +50 lb
16 referenced values
MPC-900-DP
ORTEC

MPC-900-DP

Manual single-sample alpha/beta counter with gasless scintillation detector

Detector type
Dual-phosphor scintillator (ZnS + plastic), Ø5.1 cm; gasless operation
Weight
40 lb; guard +7 lb; shield +50 lb
15 referenced values
ORTEC 276L
ORTEC

ORTEC 276L

Low-power PMT base with preamplifier

PMT compatibility
10-stage, 14-pin; TRW 3B14 socket (JEDEC B14-38); directly compatible with many integrated NaI-PMT assemblies
Conversion gain
Nominally 5 µV/eV with a 2 × 2 in NaI(Tl) crystal and PMT gain of 10⁶
Weight
0.65 kg net
14 referenced values
ORTEC 269
ORTEC

ORTEC 269

PMT base for 14- and 12-stage, 20-pin photomultipliers

PMT compatibility
14- or 12-stage, 20-pin socket (JEDEC B20-102), including Hamamatsu R1250; Philips XP2020, XP2020Q, XP2040, XP2040Q, XP2041, XP2041Q, XP2212B, XP2230B, XP2233B, XP2262B; EMI 9813K
Weight
0.63 kg net
6 referenced values
ORTEC 266
ORTEC

ORTEC 266

PMT base for 10-stage, 14-pin photomultipliers

PMT compatibility
10-stage, 14-pin; TRW 3B14 socket (JEDEC B14-38)
Weight
0.37 kg net
6 referenced values
ORTEC 265A
ORTEC

ORTEC 265A

PMT base for 12-stage, 21-pin photomultipliers, for fast timing

PMT compatibility
12-stage, standard 21-pin sockets, including Hamamatsu R329, R1332, R1333 and Burle 8575, 8850, C31000M
Weight
0.63 kg net
6 referenced values
ORTEC 567
ORTEC

ORTEC 567

Time-to-amplitude converter / SCA

Base full-scale ranges
50, 100, 200 ns
Range multipliers
1, 10, 100, 1000, 10 000
Maximum full-scale range
2 ms
9 referenced values
ORTEC 566
ORTEC

ORTEC 566

Time-to-amplitude converter

Base full-scale ranges
50, 100, 200 ns
Range multipliers
1, 10, 100, 1000, 10 000
Maximum full-scale range
2 ms
8 referenced values
ORTEC 462
ORTEC

ORTEC 462

Time calibrator

Selectable calibration periods
10, 20, 40, 80, 160, 320, 640 ns; 1.28, 2.56, 5.12, 10.24 µs
Calibration range
80 ns–81.92 µs
Absolute accuracy, 10 ns period
±10 ps
8 referenced values
ORTEC 850
ORTEC

ORTEC 850

Quad single-channel analyzer

Independent channels
4
Dynamic range per channel
500:1
Threshold range
20 mV–9.99 V
9 referenced values
ORTEC 552
ORTEC

ORTEC 552

Pulse-shape analyzer / timing SCA

Dynamic range
200:1
Minimum lower threshold
40 mV
Linear input range
0…+10 V
9 referenced values
ORTEC 551
ORTEC

ORTEC 551

Timing single-channel analyzer

Dynamic range
200:1
Minimum lower threshold
50 mV
Linear input range
0…+10 V
8 referenced values
ORTEC 550A
ORTEC

ORTEC 550A

Single-channel analyzer

Dynamic range
500:1
Linear input range
+20 mV…+10 V
Window width
0–1 V
8 referenced values
ORTEC 9307
ORTEC

ORTEC 9307

pico-TIMING discriminator

Input amplitude range
−50 mV…−5 V
Input pulse width (FWHM)
400 ps–5 ns
Threshold range
−25 mV…−1 V
9 referenced values
ORTEC 935A
ORTEC

ORTEC 935A

Quad constant-fraction discriminator

Independent channels
4
Input impedance
50 Ω
Linear input range
−20 mV…−5 V
10 referenced values
ORTEC 584
ORTEC

ORTEC 584

Constant-fraction discriminator

Input amplitude range
0…−5 V
Threshold range
−5 mV…−1 V
Input impedance
50 Ω
8 referenced values
ORTEC CF8000
ORTEC

ORTEC CF8000

Octal constant-fraction discriminator

Channels
8
9 referenced values
ORTEC GG8020
ORTEC

ORTEC GG8020

Octal gate and delay generator

Independent channels
8
Short delay range
70–1000 ns
Long delay range
0.4–10 µs
9 referenced values
ORTEC DB463
ORTEC

ORTEC DB463

Delay box

Independent sections
4
Relative delay per section
0–63.5 ns
Delay increment
0.5 ns
8 referenced values
ORTEC CO4020
ORTEC

ORTEC CO4020

Quad four-input logic unit

Independent channels
4
Signal inputs per channel
4
Minimum input pulse width
3 ns
9 referenced values
ORTEC 542
ORTEC

ORTEC 542

Linear gate and stretcher

Linear amplitude range
+0.1…+10 V
Output delay after peak detection
0.5–5 µs
Output pulse width
0.5–5 µs
9 referenced values
ORTEC 499
ORTEC

ORTEC 499

Fast/slow NIM logic converter

NIM-to-TTL channels
8
TTL-to-NIM channels
8
Maximum NIM-to-TTL frequency
60 MHz
9 referenced values
ORTEC 426
ORTEC

ORTEC 426

Linear gate

Linear amplitude range
+0.2…+10 V
Gate width
0.3–4 µs
Gain
1
8 referenced values
ORTEC 425A
ORTEC

ORTEC 425A

Nanosecond delay

Selectable added delay
0–63 ns
Fixed minimum delay
2.0 ns
Total delay
2–65 ns
9 referenced values
ORTEC 418A
ORTEC

ORTEC 418A

Universal coincidence

Inputs
5
Coincidence requirement
1–5 coincident pulses
Input A resolving time
100 ns–2 µs
9 referenced values
ORTEC 416A
ORTEC

ORTEC 416A

Gate and delay generator

Delay
0.1–110 µs
Output pulse width
0.4–4 µs
Output amplitude
+2…+10 V / −2…−10 V
8 referenced values
ORTEC 414A
ORTEC

ORTEC 414A

Fast coincidence

Coincidence inputs
3
Anticoincidence inputs
1
Resolving time (2τ)
10–110 ns
8 referenced values
ORTEC 480
ORTEC

ORTEC 480

Pulser

Net weight
0.9 kg
9 referenced values
ORTEC 419
ORTEC

ORTEC 419

Precision pulse generator

Net weight
2.0 kg
9 referenced values
ORTEC EASY-MCS
ORTEC

ORTEC EASY-MCS

Multichannel scaler

Channels per scan
4–65,536 with ramp off; 4–32,768 with ramp on
Capacity per channel
1,073,741,823 counts; 30 bits
12 referenced values
ORTEC 4006
ORTEC

ORTEC 4006

Minibin and power supply

Net weight
12 kg
9 referenced values
ORTEC 4003
ORTEC

ORTEC 4003

Preamplifier power output

Net weight
0.74 kg
8 referenced values
ORTEC 4002P
ORTEC

ORTEC 4002P

Portable power supply

Net weight
10.9 kg
9 referenced values
ORTEC 4002E
ORTEC

ORTEC 4002E

NIM bin power supply

Maximum total DC output power
300 W; 0–50°C
Outputs and maximum current per rail
±6 V: 12 A; ±12 V: 4 A; ±24 V: 2 A
Mains frequency
47–63 Hz
8 referenced values
ORTEC 4002D
ORTEC

ORTEC 4002D

NIM bin power supply

Maximum total DC output power
160 W; 0–50°C
Outputs and maximum current per rail
±6 V: 10 A; ±12 V: 3 A; ±24 V: 1.5 A
Mains frequency
50–60 Hz
8 referenced values
ORTEC 4002A
ORTEC

ORTEC 4002A

NIM bin power supply

Maximum total DC output power
96 W; 0–50°C
Outputs and maximum current per rail
±12 V: 2 A; ±24 V: 1 A
Mains frequency
47–63 Hz
8 referenced values
ORTEC 4001C
ORTEC

ORTEC 4001C

NIM bin

Net weight, approximate
5.0 kg
8 referenced values
ORTEC 4001A
ORTEC

ORTEC 4001A

NIM bin

Net weight, approximate
5.0 kg
8 referenced values
ORTEC 710
ORTEC

ORTEC 710

Quad detector bias supply

Independent channels
4
Net weight
1.4 kg
10 referenced values
ORTEC 660
ORTEC

ORTEC 660

Dual detector bias supply

Independent bias supplies
2
9 referenced values
ORTEC 659
ORTEC

ORTEC 659

Detector bias supply

Independent bias supplies
1
9 referenced values
ORTEC 556H
ORTEC

ORTEC 556H

High-voltage power supply

Net weight
5.7 kg
10 referenced values
ORTEC 556
ORTEC

ORTEC 556

High-voltage power supply

Net weight
3.6 kg
10 referenced values
ORTEC 428
ORTEC

ORTEC 428

Detector bias supply

Bias outputs
2
Net weight
1.82 kg
9 referenced values
ORTEC 439
ORTEC

ORTEC 439

Digital current integrator

Current range
10⁻⁹–10⁻² A
9 referenced values
ORTEC 9349
ORTEC

ORTEC 9349

Log/lin ratemeter

Linear full-scale ranges
11 ranges: 10–10⁶ counts/s (1–3–10 steps)
Logarithmic range
10–10⁶ counts/s; 5 decades
Input signal
Fast negative NIM; −600–−1800 mV; 50 Ω
9 referenced values
ORTEC 978
ORTEC

ORTEC 978

Dual timer

Timer sections
2
Net weight
0.9 kg
9 referenced values
ORTEC 976
ORTEC

ORTEC 976

Quad counter/timer

Main counters
4
Display per main counter
8 digits
11 referenced values
ORTEC 996
ORTEC

ORTEC 996

Counter and timer

Counters
1
Capacity per counter
0–99,999,999; 8 decades
12 referenced values
ORTEC 995
ORTEC

ORTEC 995

Dual counter

Counters
2
Capacity per counter
0–99,999,999; 8 decades
9 referenced values
ORTEC 994
ORTEC

ORTEC 994

Dual counter and timer

Counters
2
Capacity per counter
0–99,999,999; 8 decades
12 referenced values
ORTEC 974A
ORTEC

ORTEC 974A

Quad counter/timer

Main channels
4
Capacity per section
8 decades
10 referenced values
ORTEC 871
ORTEC

ORTEC 871

Timer and counter

Counting sections
2
Capacity per section
8 decades
Net weight
1.5 kg
9 referenced values
ORTEC 449-2
ORTEC

ORTEC 449-2

Log/lin ratemeter with audible output

Net weight
1.5 kg
9 referenced values
ORTEC 449
ORTEC

ORTEC 449

Log/lin ratemeter

Net weight
1.5 kg
8 referenced values
ORTEC 925-SCINT ACE Mate
ORTEC

ORTEC 925-SCINT ACE Mate

Amplifier, preamplifier, bias and SCA

Gain
5–1250
Peaking time
2 µs
Pulse shape
Semi-Gaussian, bipolar
11 referenced values
ORTEC VT120C
ORTEC

ORTEC VT120C

Preamplifier

Gain
20 ±10 %; non-inverting
Rise time
≤1 ns
Equivalent input noise
≤20 µV rms
9 referenced values
ORTEC VT120B
ORTEC

ORTEC VT120B

Preamplifier

Gain
200 ±10 %; inverting
Rise time
≤1 ns
Equivalent input noise
≤20 µV rms
9 referenced values
ORTEC VT120A
ORTEC

ORTEC VT120A

Preamplifier

Gain
200 ±10 %; non-inverting
Rise time
≤1 ns
Equivalent input noise
≤20 µV rms
9 referenced values
ORTEC 9326
ORTEC

ORTEC 9326

Preamplifier

Voltage gain
5, 10 or 20; non-inverting
Output rise time
<1 ns
Equivalent input noise
<100 µV rms
8 referenced values
ORTEC 9306
ORTEC

ORTEC 9306

Preamplifier

Identical outputs
2
11 referenced values
ORTEC 9305
ORTEC

ORTEC 9305

Preamplifier

Voltage gain
Nominally 5–10; non-inverting
Output rise time
<3 ns; ±5 V into 50 Ω
Equivalent input noise
<25 µV; HP3400A rms meter; <30 µV at 200 MHz wideband
6 referenced values
ORTEC 9301
ORTEC

ORTEC 9301

Preamplifier

Voltage gain
10 ±2 %; non-inverting
Output rise time
<1.5 ns
Equivalent input noise
<25 µV rms
7 referenced values
ORTEC 142PC
ORTEC

ORTEC 142PC

Preamplifier

Nominal sensitivity
4 V/pC
Dynamic input capacitance
1000 pF
Guaranteed noise
<340 rms electrons at 0 pF; <485 at 100 pF
10 referenced values
ORTEC 142IH
ORTEC

ORTEC 142IH

Preamplifier

Energy range, Si
0–100 MeV
10 referenced values
ORTEC 142AH
ORTEC

ORTEC 142AH

Preamplifier

Recommended input capacitance
0–100 pF
Maximum detector bias
±5000 V
Nominal sensitivity, Si equivalent
20 mV/MeV
8 referenced values
ORTEC 142C
ORTEC

ORTEC 142C

Preamplifier

Energy range, Si
0–400 MeV
8 referenced values
ORTEC 142B
ORTEC

ORTEC 142B

Preamplifier

Energy range, Si
0–400 MeV
8 referenced values
ORTEC 142A
ORTEC

ORTEC 142A

Preamplifier

Energy range, Si
0–200 MeV
8 referenced values
ORTEC 113
ORTEC

ORTEC 113

Preamplifier

Rise time
<60 ns
Designed fall time constant
50 µs, assuming a signal source impedance of 1 MΩ
Integral nonlinearity
≤±0.02 %
8 referenced values
ORTEC 9327
ORTEC

ORTEC 9327

Amplifier and timing discriminator

Selectable input range
0–−30 mV or 0–−150 mV
Equivalent input noise
<100 µV rms; 0–−30 mV range
Walk
Typically <±40 ps; top 90% of full scale, 300 ps FWHM input pulse
8 referenced values
ORTEC 9302
ORTEC

ORTEC 9302

Amplifier and discriminator

Gain
20 or 200; non-inverting
Rise time
Typically 3.0 ns
Noise at maximum gain
≤10 µV
9 referenced values
ORTEC 9309-4
ORTEC

ORTEC 9309-4

Timing amplifier

Channels
4
8 referenced values
ORTEC 590A
ORTEC

ORTEC 590A

Amplifier and timing SCA

Gain
5–1250
Shaping time constants
0.5; 1.5; 3 µs
Integral nonlinearity
<±0.05 % at 1.5 µs
10 referenced values
ORTEC 863
ORTEC

ORTEC 863

Timing amplifier

Channels
4
10 referenced values
ORTEC 579
ORTEC

ORTEC 579

Timing amplifier

Channels
1
9 referenced values
ORTEC 474
ORTEC

ORTEC 474

Timing amplifier

Channels
1
9 referenced values
ORTEC 533
ORTEC

ORTEC 533

Summing amplifier

Amplifiers
2
9 referenced values
ORTEC 460
ORTEC

ORTEC 460

Spectroscopy amplifier

Gain
Coarse 10–1000 × fine 0.3–1
Integration time constants
0.04; 0.1; 0.25 µs
Delay lines
1 µs; both lines
9 referenced values
ORTEC 427A
ORTEC

ORTEC 427A

Delay amplifier

Gain at zero delay
1 ±2 %
Selectable delay
0–4.75 µs
Minimum delay
60 ns
9 referenced values
ORTEC 673
ORTEC

ORTEC 673

Spectroscopy amplifier and gated integrator

Gain
1–1500
Shaping time constants
0.25; 0.5; 1; 2; 3; 6 µs
Integral nonlinearity
<±0.05 %; typically 0.025 %; unipolar, 2 µs
9 referenced values
ORTEC 672
ORTEC

ORTEC 672

Spectroscopy amplifier

Gain
2.5–1500
Shaping time constants
0.5; 1; 2; 3; 6; 10 µs
Integral nonlinearity
<±0.025 %; 0–+10 V, unipolar; 2 µs Gaussian, AUTO BLR; manual PZ
9 referenced values
ORTEC 671
ORTEC

ORTEC 671

Spectroscopy amplifier

Gain
2.5–1500
Shaping time constants
0.5; 1; 2; 3; 6; 10 µs
Integral nonlinearity
<±0.025 %; 0–+10 V, unipolar; 2 µs Gaussian, AUTO BLR
9 referenced values
ORTEC 855
ORTEC

ORTEC 855

Spectroscopy amplifier

Channels
2
9 referenced values
ORTEC 575A
ORTEC

ORTEC 575A

Spectroscopy amplifier

Channels
1
9 referenced values
ORTEC 572A
ORTEC

ORTEC 572A

Spectroscopy amplifier

Gain
1–1500
Shaping time constants
0.5; 1; 2; 3; 6; 10 µs
Integral nonlinearity
<±0.05 % at 2 µs
9 referenced values
ORTEC 570
ORTEC

ORTEC 570

Spectroscopy amplifier

Gain
1–1500
Shaping time constants
0.5; 1; 2; 3; 6; 10 µs
Integral nonlinearity
<±0.05 % at 2 µs
8 referenced values
ORTEC 296
ORTEC

ORTEC 296

PMT base with preamplifier

PMT compatibility
10-stage, 14-pin; JEDEC B14-38
Weight
0.5 kg net
10 referenced values
ORTEC 276
ORTEC

ORTEC 276

PMT base with preamplifier

PMT compatibility
10-stage, 14-pin; JEDEC B14-38
Weight
0.65 kg net
9 referenced values
digiBASE-E
ORTEC

digiBASE-E

Digital MCA in PMT base

Detector type
Scintillators including NaI(Tl) and LaBr₃(Ce)
Spectrum channels
256–2,048
Weight
0.36 kg net
12 referenced values
ASPEC-927 dual MCB
ORTEC

ASPEC-927 dual MCB

Dual NIM multichannel buffer

Spectrum channels
512–16,384 per ADC, software selectable
Weight
0.9 kg net
13 referenced values
digiDART-LF
ORTEC

digiDART-LF

Portable MCA for scintillation detectors

Detector type
NaI(Tl) and scintillators such as LaBr₃
Spectrum channels
512–2 k, software selectable
14 referenced values
DSPEC-LF
ORTEC

DSPEC-LF

Digital gamma spectrometer

Detector type
HPGe; NaI through appropriate DIM
Spectrum channels
512–16 k, software selectable
Weight
1.0 kg
12 referenced values
DSPEC-Jr. 2.0
ORTEC

DSPEC-Jr. 2.0

Digital gamma spectrometer

Detector type
HPGe; NaI through appropriate DIM
Spectrum channels
512–16 k, software selectable
Weight
1.0 kg
12 referenced values
DSPEC-Pro
ORTEC

DSPEC-Pro

Digital gamma spectrometer

Detector type
HPGe; NaI through appropriate DIM
Spectrum channels
512–16 k, software selectable
Weight
1.0 kg
12 referenced values
digiBASE
ORTEC

digiBASE

MCA and PMT base for nai(tl)

Detector type
NaI(Tl) scintillation detectors
Spectrum channels
1,024
Weight
280 g, digiBASE only
12 referenced values

Monitoring & preparedness

3 products

PINS3-CW-G2
ORTEC

PINS3-CW-G2

Chemical identification with a neutron generator – no ²⁵²Cf or liquid nitrogen

Relative efficiency
>50% typical (ANSI/IEEE 325-1996)
Energy resolution at 122 keV
<1600 eV FWHM (warranted at optimum settings and depending on detector type)
Energy resolution at 1.33 MeV
≤2.5 keV FWHM at 1,332 keV (warranted at optimum settings and depending on detector type)
14 referenced values
PINS3-CF
ORTEC

PINS3-CF

Chemical and explosives identification with a ²⁵²Cf neutron source

Relative efficiency
>50% typical (ANSI/IEEE 325-1996)
Energy resolution at 122 keV
<1600 eV FWHM (warranted at optimum settings and depending on detector type)
Energy resolution at 1.33 MeV
≤2.5 keV FWHM at 1,332 keV (warranted at optimum settings and depending on detector type)
15 referenced values
GRACE
ORTEC

GRACE

Man-portable system that identifies chemicals in munitions and sealed containers

Relative efficiency
>50% typical (ANSI/IEEE 325-1996)
Energy resolution at 122 keV
<1600 eV FWHM (warranted at optimum settings and depending on detector type)
Energy resolution at 1.33 MeV
≤2.5 keV FWHM at 1,332 keV (warranted at optimum settings and depending on detector type)
14 referenced values

Software

17 products

Vista FC
ORTEC

Vista FC

Alpha/beta counter control software for health physics

Primary function
Control software for health-physics sample counting with the WPC-9550 and other compatible systems
Sample parameters
Input of e.g. air volume and liquid volume
Access control
Password-protected instrument setup
5 referenced values
Vista 2000
ORTEC

Vista 2000

Alpha/beta counter control and analysis software for radiochemistry

Primary function
Analysis, QC and reporting for radiochemistry in the application that controls the alpha/beta counter
Intended system
Any mix of up to 64 detectors (MDS, WPC-9550 and MPC-9300); controls single and multi-detector, automatic and manual systems
Quality control
Trends, efficiency and background
6 referenced values
FoodGuard-2-AK
ORTEC

FoodGuard-2-AK

Add-on kit that turns a GammaVision system into a FoodGuard-2 station

Required combination
Existing ORTEC gamma spectrometry system running GammaVision under Windows XP or Windows 7 (32-bit)
Contents
FoodGuard-2 software (FG-2-B32, version 1.0.11 or later), CONNECTIONS upgrade (797230, version 7.02.03 or later), 6 × 2-litre Marinelli beakers and check source (2-litre Marinelli beaker filled with KCl, ⁴⁰K)
Detector requirement
The beakers suit HPGe detectors with an endcap diameter of 83 mm or less
7 referenced values
CONNECTIONS Programmer’s Toolkit
ORTEC

CONNECTIONS Programmer’s Toolkit

Software · developer tools

Primary function
Control ORTEC instruments from custom Windows applications
Instrument support
ORTEC CONNECTIONS-compatible MCA instruments and EASY-NIM 928
Programming interfaces
ActiveX and DLL
8 referenced values
FRAM
ORTEC

FRAM

Software · analysis

Primary function
Plutonium and uranium isotopic analysis from gamma spectra
Analysis method
Fixed-energy Response-function Analysis with Multiple efficiency
Detector support
HPGe, LaBr3 and CZT detectors, incl. ORTEC Detective and trans-SPEC; pixelated CZT analysis added in version 7.1
8 referenced values
NewLabVision 4 ( LVis )
ORTEC

LabVision 4 ( LVis )

Software · analysis

Primary function
Nuclear spectrometry counting-laboratory management
Analysis engine
GammaVision and the tRAYcy Monte Carlo algorithm
Measurement workflow
Single-detector and automated multi-detector workflows
8 referenced values
ISOTOPIC
ORTEC

ISOTOPIC

ORTEC measurement and analysis software

Primary function
Gamma-spectrometric waste assay and site characterization
Measurement systems
High-resolution HPGe spectra from large bulk samples
Sample geometries
Boxes, cylinders/pipes, point sources, small containers and infinite plane
10 referenced values
DataMaster
ORTEC

DataMaster

ORTEC measurement and analysis software

Primary function
Spectrum-file format conversion
Interactive mode
Graphical spectrum preview with sample ID and acquisition times
Batch conversion
Individual files or multiple files of same input format
8 referenced values
Renaissance
ORTEC

Renaissance

ORTEC measurement and analysis software

Primary function
Whole-body counting and internal contamination monitoring
Measurement systems
HPGe and NaI detectors; single or multiple
System configuration
Fixed position or automated scanning; stand-up, chair and bed systems
10 referenced values
Nuclide Navigator Pro
ORTEC

Nuclide Navigator Pro

ORTEC measurement and analysis software

Primary function
Interactive nuclide chart and reference database
Nuclide data
Gamma, alpha and beta energies, yields, half-lives and decay relationships
Library management
Create gamma-analysis libraries for GammaVision; ORTEC LIB and XML
8 referenced values
ANGLE
ORTEC

ANGLE

ORTEC measurement and analysis software

Primary function
Gamma-spectroscopy efficiency calculation and calibration transfer
Measurement systems
HPGe, Ge(Li) and NaI; coaxial, planar and well configurations as applicable
Calculation method
Efficiency Transfer with Monte Carlo modelling in ANGLE5
10 referenced values
GlobalValue
ORTEC

GlobalValue

ORTEC measurement and analysis software

Primary function
Productivity suite for GammaVision
Automation
Preconfigured scripts for sample and QA measurements
Integration
Microsoft Word, Excel, Access and data/document management systems
8 referenced values
GammaVision Report Writer
ORTEC

GammaVision Report Writer

ORTEC measurement and analysis software

Primary function
Database and reporting for GammaVision analysis results
Integration
Integrated reporting option in GammaVision or standalone program
Database
Microsoft Access
8 referenced values
MAESTRO-Pro
ORTEC

MAESTRO-Pro

ORTEC measurement and analysis software

Spectrum channels
Supports 32 k and 64 k spectra
10 referenced values
AlphaVision
ORTEC

AlphaVision

Alpha spectrometry software

Measurement systems
Alpha spectrometry with solid-state detectors
Detector control
Up to 256 detectors in common interface, with software-controllable instruments
Calibration
Energy and efficiency; historical calibration records
10 referenced values
GammaVision
ORTEC

GammaVision

Gamma spectroscopy software

Spectrum channels
Up to 64 k
10 referenced values
MAESTRO
ORTEC

MAESTRO

MCA and spectroscopy software

Primary function
MCA emulation for gamma and alpha spectroscopy
Spectrum display
Up to 8 live detectors and 8 saved spectra simultaneously
Network detectors
Up to 250 detector systems via ORTEC CONNECTIONS
9 referenced values

Calibration & reference sources

2 products

ILLUSTRATION
ORTEC

Exempt Quantity Radioactive Sources

Check sources for energy calibration in 2.5 cm plastic disks

Use
Check sources for energy calibration
Format
Sealed plastic disks, 2.5 cm diameter
Licensing
Exempt from USNRC and US State licensing; no special storage or disposal requirements there
6 referenced values
ORTEC Am-1C
ORTEC

ORTEC Am-1C

Alpha calibration source

Radionuclide
²⁴¹Am
Nominal activity
0.1 µCi
Calibration
Within 1 % of absolute disintegration rate
8 referenced values
Contact us

Questions about this product?