RADEAGLET-R

Handheld isotope identification

Identify radioactive materials in the field. A handheld instrument for emergency response, security and environmental monitoring.

Detector type
NaI(Tl) or LaBr₃(Ce), model dependent1
Energy range, NaI
NaI: 15 keV–3 MeV1
Spectrum channels
2,0481
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-16

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Designed for regular field use.
  • Share measurement data through wired and wireless connections.
  • Select a detector configuration for your application.

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeNaI(Tl) or LaBr₃(Ce), model dependent1
Neutron detection³He detector in models with N suffix1

Performance

Energy resolutionAt 662 keV, room temperature: NaI ≤7.2%; LaBr₃ ≤3.2%1

Measuring range

Energy range, NaINaI: 15 keV–3 MeV1
Energy range, GM dose measurementGM: 45 keV–1.5 MeV1
Dose-rate rangeTotal 20 nSv/h–1 Sv/h (NaI 20 nSv/h–250 µSv/h; GM >250 µSv/h–1 Sv/h)1
Sensitivity (¹³⁷Cs gamma)>1,600 cps per µSv/h1
Dose-rate accuracyNaI: ±10% for ¹³⁷Cs (662 keV), ²⁴¹Am (59 keV) and ⁶⁰Co (1172 and 1332 keV); GM: ±30% for ¹³⁷Cs (662 keV)1
Thermal neutron sensitivity1.6 cps/nv ±10%, unmoderated (models with ³He detector)1

Electronics & signal

Spectrum channels2,0481
Overload threshold≥1 Sv/h1

Cooling

Storage>16 GB (1,000,000 spectra)1

Software & data

Nuclide library55 nuclides plus Beta+, neutrons, RGPu, RGPu-HS, WGPu and WGPu-HS: ²²⁸Ac, ²⁴¹Am, ¹³³Ba, ¹⁴⁰Ba, Beta+, ²⁰⁷Bi, ¹⁰⁹Cd, ¹¹⁵Cd, ¹¹⁵ᵐCd, ¹⁴¹Ce, ²⁵²Cf (requires neutron detection), ⁵⁷Co, ⁶⁰Co, ⁵¹Cr, ¹³⁴Cs, ¹³⁷Cs, ¹⁵²Eu, ¹⁵⁵Eu, ⁶⁷Ga, ⁶⁸Ga, ¹²³I, ¹²⁵I, ¹³¹I, ¹³²I, ¹¹¹In, ¹⁹²Ir, ⁴⁰K, ¹⁴⁰La, ¹⁷⁶Lu, ¹⁷⁷Lu, ⁵⁴Mn, ⁹⁹Mo, ²²Na, ⁹⁵Nb, ¹⁴⁷Nd, neutrons, ²³⁷Np, ¹⁴⁴Pr, ²³⁸Pu, RGPu, RGPu-HS, WGPu, WGPu-HS, ²²⁶Ra, ¹⁰³Ru, ¹²⁵Sb, ⁷⁵Se, ⁹⁰Sr, ⁹⁹ᵐTc, ¹³²Te, ²³²Th, ²⁰¹Tl, ²³²U, ²³³U, ²³⁵U, ²³⁸U, ¹³¹ᵐXe, ¹³³Xe, ¹³³ᵐXe, ¹³⁵Xe, ⁹⁵Zr1

Connectivity & interface

Display3.5-inch colour TFT, 640 × 4801
CommunicationUSB, Wi-Fi, Bluetooth and LAN; wireless dongles included1

Power & battery

Battery life>15 hours, standard operation at room temperature1
BatteriesRechargeable, exchangeable Li-ion1

Mechanical

Detector dimensionsNaI: 50.8 × 25.4 mm; LaBr₃: 25.4 × 25.4 mm1
Dimensions90 × 280 × 110 mm (W × L × H)1
Nominal weight2SG models 1.5 kg; 2SG-N models 1.54 kg; 1LG and 1LG-P 1.46 kg; 1LG-N and 1LG-N-P 1.51 kg1

Environment & ratings

Operating temperature−20 to +55 °C1
IP ratingIP65 under IEC 605291
Humidity0–95%, non-condensing1

Ordering & accessories

Dose-rate range by modelDetector: NaI models 0.01–200 µSv/h, LaBr₃ models 0.01–350 µSv/h; GM: up to 1 Sv/h1

General

CalibrationExternal ⁴⁰K source (start-up 165 s) or embedded ¹³⁷Cs source, 111 Bq (3 nCi) (start-up 145 s); LaBr₃ stabilises on an internal lanthanum peak1
File formatsANSI N42.42 (xml) and spe (IAEA), compatible with third-party analysis software1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Models

12 models in the series. Filter or scroll the table to compare.

12 / 12
ModelGamma detector2Crystal dimensions2Neutron detectionGPS3Embedded calibration source3Energy resolution at 662 keV2Nominal weight2Energy range, NaI1
RADEAGLET-R-1LGLaBr₃(Ce)25.4 × 25.4 mmNone3Not includedNot included≤3.2 % FWHM, ambient room temperature1.46 kg–
RADEAGLET-R-1LG-NLaBr₃(Ce)25.4 × 25.4 mm³He included2Not includedNot included≤3.2 % FWHM, ambient room temperature1.51 kg–
RADEAGLET-R-1LG-N-PLaBr₃(Ce)25.4 × 25.4 mm³He included2IncludedNot included≤3.2 % FWHM, ambient room temperature1.51 kg–
RADEAGLET-R-1LG-PLaBr₃(Ce)25.4 × 25.4 mmNone3IncludedNot included≤3.2 % FWHM, ambient room temperature1.46 kg–
RADEAGLET-R-2SGNaI(Tl)50.8 × 25.4 mmNone3Not includedNot included≤7.2 % FWHM, ambient room temperature1.5 kgNaI: 15 keV–3 MeV
RADEAGLET-R-2SG-ENaI(Tl)50.8 × 25.4 mmNone3Not includedIncluded≤7.2 % FWHM, ambient room temperature1.5 kgNaI: 15 keV–3 MeV
RADEAGLET-R-2SG-NNaI(Tl)50.8 × 25.4 mm³He included2Not includedNot included≤7.2 % FWHM, ambient room temperature1.54 kgNaI: 15 keV–3 MeV
RADEAGLET-R-2SG-N-ENaI(Tl)50.8 × 25.4 mm³He included2Not includedIncluded≤7.2 % FWHM, ambient room temperature1.54 kgNaI: 15 keV–3 MeV
RADEAGLET-R-2SG-N-PNaI(Tl)50.8 × 25.4 mm³He included2IncludedNot included≤7.2 % FWHM, ambient room temperature1.54 kgNaI: 15 keV–3 MeV
RADEAGLET-R-2SG-N-P-ENaI(Tl)50.8 × 25.4 mm³He included2IncludedIncluded≤7.2 % FWHM, ambient room temperature1.54 kgNaI: 15 keV–3 MeV
RADEAGLET-R-2SG-PNaI(Tl)50.8 × 25.4 mmNone3IncludedNot included≤7.2 % FWHM, ambient room temperature1.5 kgNaI: 15 keV–3 MeV
RADEAGLET-R-2SG-P-ENaI(Tl)50.8 × 25.4 mmNone3IncludedIncluded≤7.2 % FWHM, ambient room temperature1.5 kgNaI: 15 keV–3 MeV

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ORTEC (AMETEK)Product page Specifications tab, 'Model Specific Specifications'; Specifications tab, 'Specifications Common to All Models' - Physical; Specifications tab, 'Specifications Common to All Models' - Radiological Performance; Ordering Information … Checked 2026-10-16
  2. 2
    Publisher: ORTEC (AMETEK)Brochure p. 10, table 'Model Specific Technical Specifications'; p. 11, 'RADEAGLET-R Ordering Information' Checked 2026-10-16
  3. 3
    Publisher: ORTEC (AMETEK)Product catalogue PDF p. 40 (printed p. 37), 'RADEAGLET-R Rugged Radioisotope Identification Device' Checked 2026-10-16
INNOPROBE
ORTEC

INNOPROBE

Alpha/beta probe for the RADEAGLET-R

Detector type
Alpha/beta-sensitive scintillator with photomultiplier (ZnS:Ag)
Count-rate range
Up to 25 kcps alpha and 20 kcps beta
Weight
300 g (0.66 lb)
15 referenced values
Detective DX1
ORTEC

Detective DX1

Portable HPGe spectroscopy

Detector type
P-type coaxial HPGe detector
Energy range
DX1/DX1-N: 40 keV–3 MeV; DX1-8/DX1-8-N: 40 keV–8 MeV
Weight
7.23 kg gamma; 7.87 kg gamma/neutron
4 models
RADEAGLE
ORTEC

RADEAGLE

Handheld isotope identification

Detector type
NaI(Tl) or LaBr₃(Ce), model dependent
Energy range
11 keV–3 MeV
Spectrum channels
2,048
20 models
A Series (A400) RIID
H3D

A Series (A400) RIID

Handheld RIID

Detector type
A400: CZT (CdZnTe)
Spectroscopy energy range
A400: 50–3000 keV
Weight
A400: 1.2 kg
6 models
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.