ORTEC ULTRA-AS

Low-background silicon detectors for alpha spectroscopy

ORTEC ULTRA-AS comprises 8 models (low-background silicon detectors for alpha spectroscopy). The models differ in active area, depletion depth and warranted resolution, among other things – compare them in the model table.

Detector type
Ion-implanted silicon, partially depleted1
Active depth
≈100 µm2
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-16

Manufacturer’s product page (opens in a new tab)

Overview

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector typeIon-implanted silicon, partially depleted1
Active depth≈100 µm2
Resolution measurement conditions²⁴¹Am 5.486 MeV alphas; standard ORTEC electronics; 1 µs shaping time constants3
Resolution measurement and warranty temperature21 ±1 °C1
Bias polarityPositive3
Resolution reference geometryThin-window point source; distance at least 2 times the detector diameter4

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Models

8 models in the series. Filter or scroll the table to compare.

8 / 8
ModelMinimum active area2Guaranteed maximum alpha resolution2Ordering mounts2Alpha Suite compatibility2Installation and spare packages
U-019-300-AS≥300 mm²≤19 keV FWHMB, C, T (closed back)ULTRA-AS in B mount is guaranteed compatible; C/T mounts require an approved specialB, C or T mount; ENS-U300: B mount, installed and system tested with an Alpha Suite spectrometer; ENS8U300: pack of eight spare detectors (not installed or system tested), only with an ALPHA-ENSEMBLE-8 system2
U-020-450-AS≥450 mm²≤20 keV FWHMB, C, T (closed back)ULTRA-AS in B mount is guaranteed compatible; C/T mounts require an approved specialB, C or T mount; ENS-U450: B mount, installed and system tested with an Alpha Suite spectrometer; ENS8U450: pack of eight spare detectors (not installed or system tested), only with an ALPHA-ENSEMBLE-8 system2
U-020-490-AS≥490 mm²≤20 keV FWHMB, C, T (closed back)ULTRA-AS in B mount is guaranteed compatible; C/T mounts require an approved specialB, C or T mount; ENS-U490: B mount, installed and system tested with an Alpha Suite spectrometer; ENS8U490: pack of eight spare detectors (not installed or system tested), only with an ALPHA-ENSEMBLE-8 system2
U-024-600-AS≥600 mm²≤24 keV FWHMB, C, T (closed back)ULTRA-AS in B mount is guaranteed compatible; C/T mounts require an approved specialB, C or T mount; ENS-U600: B mount, installed and system tested with an Alpha Suite spectrometer; ENS8U600: pack of eight spare detectors (not installed or system tested), only with an ALPHA-ENSEMBLE-8 system2
U-029-900-AS≥900 mm²≤29 keV FWHMB, CULTRA-AS in B mount is guaranteed compatible; C mount requires an approved specialB or C mount; ENS-U900: B mount, installed and system tested with an Alpha Suite spectrometer; ENS8U900: pack of eight spare detectors (not installed or system tested), only with an ALPHA-ENSEMBLE-8 system2
U-037-1200-AS≥1200 mm²≤37 keV FWHMB, CULTRA-AS in B mount is guaranteed compatible; C mount requires an approved specialB or C mount; ENS-U1200: B mount, installed and system tested with an Alpha Suite spectrometer; ENS8U1200: pack of eight spare detectors (not installed or system tested), only with an ALPHA-ENSEMBLE-8 system2
U-053-2000-AS≥2000 mm²≤53 keV FWHMB, CULTRA-AS in B mount is guaranteed compatible; C mount requires an approved specialB or C mount; ENS-U2000: B mount, installed and system tested with an Alpha Suite spectrometer3
U-064-3000-AS≥3000 mm²≤64 keV FWHMB, CULTRA-AS in B mount is guaranteed compatible; C mount requires an approved specialB or C mount; ENS-U3000: B mount, installed and system tested with an Alpha Suite spectrometer3

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ORTEC (AMETEK)Product page ULTRA / ULTRA AS comparison table ('Diode Structure') and footnote †; footnote * below the introduction text Checked 2026-10-16
  2. 2
    Publisher: ORTEC (AMETEK)Product catalogue PDF p. 4 (printed p. 1), 'ULTRA-AS Ion-Implanted Detectors' note; PDF p. 4 (printed p. 1), table 'ULTRA-AS Ion-Implanted Detectors', Active Area column; PDF p. 11: 'The next group of dig; PDF p. 4 (printed p. 1), table 'ULTRA-AS Ion-Implanted Detectors'; PDF p. 11 (printed p. 8), table 'Standard Mounting Information' … Checked 2026-10-16
  3. 3
    Publisher: ORTEC (AMETEK)Brochure p. 2–3, footnote * under the ULTRA / ULTRA-AS ordering tables; p. 1, footnote **; p. 3, table 'ULTRA-AS to be installed and system tested with an Alpha Suite Spectrometer. Supplied in B Mount' Checked 2026-10-16
  4. 4
    Publisher: ORTEC (AMETEK)Application note PDF p. 3, 'Energy Resolution and Noise' Checked 2026-10-16
ORTEC C Series
ORTEC

ORTEC C Series

Annular partially depleted surface-barrier detectors

Detector type
Annular partially depleted silicon surface barrier
16 models
ORTEC B Series
ORTEC

ORTEC B Series

Totally depleted silicon surface-barrier detectors

Detector type
Totally depleted silicon surface barrier
74 models
ORTEC A Series
ORTEC

ORTEC A Series

Partially depleted silicon surface-barrier detectors

Detector type
Partially depleted silicon surface barrier
29 models
ORTEC R Series
ORTEC

ORTEC R Series

Ruggedized silicon surface-barrier detectors

49 models
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.