FoodGuard-1
NaI-based system for rapid food screening
- Detector type
- NaI(Tl) 3 × 3 in (ORTEC 905-4) with digiBASE: 14-pin PMT base with integrated bias supply, preamplifier and digital MCA
- Typical energy resolution, Cs-137
- 8% at 662 keV

Bild: ORTEC
HPGe workstation for quantitative determination of radionuclides in food
Complete workstation for measuring gamma-emitting radioactive contaminants in food, water and other agricultural samples after an accident or terrorist incident. With a high-resolution HPGe detector, every gamma-emitting radionuclide is quantified as specific activity in Bq/kg or Bq/litre. An administrator sets up sample types, alarm limits and reports, after which the operator just enters the sample information and starts counting.
Download product sheet (PDF)All values with references – for tender documents
Specifications checked against the manufacturer’s documents on 2026-10-17
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.
| Detector type | High-resolution HPGe detector1 |
|---|---|
| Sample geometry | 2-litre Marinelli beakers; additional containers and geometries via selectable calibration files (new calibrations created with GammaVision)1 |
| Relative efficiency | 20–60%; detector and cooling chosen when ordering1 |
|---|
| Options | GammaVision (spectrum analysis), ANGLE (efficiency transfer between geometries) and Nuclide Navigator (nuclide database)2 |
|---|
| Results | Specific activity in Bq/kg or Bq/litre for every gamma-emitting radionuclide in the sample1 |
|---|---|
| Alarm | Configurable alarms when activity level, percentage or sum of activities is exceeded; editable limits tables derived from international standards (examples from e.g. the US FDA and WHO)1 |
| Reporting | Customizable reports in HTML and PDF format1 |
| Calibration | Supplied pre-calibrated with a ⁴⁰K check source1 |
| Cs-137 MDC | 0.75 Bq/L in 10 minutes; 0.5 Bq/L in 30 minutes (20% detector, 2-litre Marinelli beakers of liquid; calculated using ISO 11929); lower with larger detectors and longer count times2 |
The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

NaI-based system for rapid food screening