FoodGuard-2

HPGe workstation for quantitative determination of radionuclides in food

Complete workstation for measuring gamma-emitting radioactive contaminants in food, water and other agricultural samples after an accident or terrorist incident. With a high-resolution HPGe detector, every gamma-emitting radionuclide is quantified as specific activity in Bq/kg or Bq/litre. An administrator sets up sample types, alarm limits and reports, after which the operator just enters the sample information and starts counting.

Detector type
High-resolution HPGe detector1
Relative efficiency
20–60%; detector and cooling chosen when ordering1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Detector efficiency (20–60%) and cooling chosen when ordering
  • Supplied pre-calibrated and configured
  • GammaVision, ANGLE and Nuclide Navigator as options

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeHigh-resolution HPGe detector1
Sample geometry2-litre Marinelli beakers; additional containers and geometries via selectable calibration files (new calibrations created with GammaVision)1

Performance

Relative efficiency20–60%; detector and cooling chosen when ordering1

Ordering & accessories

OptionsGammaVision (spectrum analysis), ANGLE (efficiency transfer between geometries) and Nuclide Navigator (nuclide database)2

General

ResultsSpecific activity in Bq/kg or Bq/litre for every gamma-emitting radionuclide in the sample1
AlarmConfigurable alarms when activity level, percentage or sum of activities is exceeded; editable limits tables derived from international standards (examples from e.g. the US FDA and WHO)1
ReportingCustomizable reports in HTML and PDF format1
CalibrationSupplied pre-calibrated with a ⁴⁰K check source1
Cs-137 MDC0.75 Bq/L in 10 minutes; 0.5 Bq/L in 30 minutes (20% detector, 2-litre Marinelli beakers of liquid; calculated using ISO 11929); lower with larger detectors and longer count times2

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ORTEC (AMETEK)Product page Overview; FoodGuard-2 System Configurations; Overview; More Information; Overview; Minimum Detectable Concentration Checked 2026-10-16
  2. 2
    Publisher: ORTEC (AMETEK)Brochure p. 3, Minimum Detectable Concentration; p. 3, Options Checked 2026-10-16
FoodGuard-1
ORTEC

FoodGuard-1

NaI-based system for rapid food screening

Detector type
NaI(Tl) 3 × 3 in (ORTEC 905-4) with digiBASE: 14-pin PMT base with integrated bias supply, preamplifier and digital MCA
Typical energy resolution, Cs-137
8% at 662 keV
12 referenced values
FoodGuard-2-AK
ORTEC

FoodGuard-2-AK

Add-on kit that turns a GammaVision system into a FoodGuard-2 station

Required combination
Existing ORTEC gamma spectrometry system running GammaVision under Windows XP or Windows 7 (32-bit)
Contents
FoodGuard-2 software (FG-2-B32, version 1.0.11 or later), CONNECTIONS upgrade (797230, version 7.02.03 or later), 6 × 2-litre Marinelli beakers and check source (2-litre Marinelli beaker filled with KCl, ⁴⁰K)
Detector requirement
The beakers suit HPGe detectors with an endcap diameter of 83 mm or less
7 referenced values
GammaVision
ORTEC

GammaVision

Gamma spectroscopy software

Spectrum channels
Up to 64 k
10 referenced values
PINS3-CW-G2
ORTEC

PINS3-CW-G2

Chemical identification with a neutron generator – no ²⁵²Cf or liquid nitrogen

Relative efficiency
>50% typical (ANSI/IEEE 325-1996)
Energy resolution at 122 keV
<1600 eV FWHM (warranted at optimum settings and depending on detector type)
Energy resolution at 1.33 MeV
≤2.5 keV FWHM at 1,332 keV (warranted at optimum settings and depending on detector type)
14 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.