Safeguards koaxial HPGe-detektor

HPGe gamma detector

Coaxial HPGe detector for safeguards, isotope-ratio determination and non-destructive assay of nuclear materials.

Detector type
HPGe, coaxial or semi-planar by SGD-GEM model1
Energy resolution at 122 keV
FWHM maximum limits 0.61–0.80 keV at 1 kcps and optimal shaping; model-dependent2
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-16

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Designed for isotope-ratio determination and safeguards work.
  • Balances low- and high-energy performance for isotope analysis.
  • Configured for the measurement application.

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeHPGe, coaxial or semi-planar by SGD-GEM model1
Crystal thicknessMinimum 15, 30, 50 or 60 mm, by model2

Performance

Energy resolution at 122 keVFWHM maximum limits 0.61–0.80 keV at 1 kcps and optimal shaping; model-dependent2
Energy resolution at 1.33 MeVFWHM maximum limits 1.7–1.8 keV at 1 kcps and optimal shaping; model-dependent2

Mechanical

Crystal diameterNominally 36, 50 or 65 mm, model-dependent2
EndcapAluminium1

Ordering & accessories

ModelsSGD-GEM-3615P4, -5030P4, -5050P4, -6560P42
Cryostat configurationsFixed, portable or custom1
Bias controlSMART-1 (-SMP), optional1
Cooling and accessoriesCryostat and dewar or other cooling device required for operation; not included with the detector. A cryostat must be ordered with a Streamline detector.2

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Models

4 models in the series. Filter or scroll the table to compare.

4 / 4
ModelDetector type1Crystal diameter2Crystal thickness2Energy resolution at 122 keV2Energy resolution at 1.33 MeV2Energy resolution at 122 keV, short shaping time2Energy resolution at 1.33 MeV, short shaping time2Endcap diameter2Ordering configurations2Relative efficiency2
SGD-GEM-3615HPGe, coaxial or semi-planar by SGD-GEM model36 mm (nominal)15 mm (minimum)≤ 0.61 keV FWHM; at 1 kcps≤ 1.7 keV FWHM; at 1 kcps≤ 0.67 keV FWHM; at 30 kcps≤ 2.0 keV FWHM; at 30 kcps70 mm (nominal)SGD-GEM-3615P4 (PopTop) / SGD-GEM-3615 (Streamline)–
SGD-GEM-5030Semi-planar HPGe, SGD-GEM50 mm (nominal)30 mm (minimum)≤ 0.65 keV FWHM; at 1 kcps≤ 1.7 keV FWHM; at 1 kcps≤ 0.75 keV FWHM; at 30 kcps≤ 2.1 keV FWHM; at 30 kcps70 mm (nominal)SGD-GEM-5030P4 (PopTop) / SGD-GEM-5030 (Streamline)13 % (nominal)
SGD-GEM-5050Coaxial HPGe (SGD-GEM)50 mm (nominal)50 mm (minimum)≤ 0.75 keV FWHM; at 1 kcps≤ 1.8 keV FWHM; at 1 kcps≤ 0.89 keV FWHM; at 30 kcps≤ 2.1 keV FWHM; at 30 kcps70 mm (nominal)SGD-GEM-5050P4 (PopTop) / SGD-GEM-5050 (Streamline)20 % (nominal)
SGD-GEM-6560HPGe, coaxial or semi-planar by SGD-GEM model65 mm (nominal)60 mm (minimum)≤ 0.80 keV FWHM; at 1 kcps≤ 1.8 keV FWHM; at 1 kcps≤ 0.96 keV FWHM; at 30 kcps≤ 2.2 keV FWHM; at 30 kcps83 mm (nominal)SGD-GEM-6560P4 (PopTop) / SGD-GEM-6560 (Streamline)50 % (nominal)

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ORTEC (AMETEK)Product page Application Considerations; More Information; Options Checked 2026-10-16
  2. 2
    Publisher: ORTEC (AMETEK)Datasheet p. 11, 'Ordering Information and Warranted Specifications'; p. 11; p. 11; p. 2 (optimum shaping time and 1 kcps); p. 11, ordering notes … Checked 2026-10-16
GEM HPGe-detektorer
ORTEC

GEM HPGe-detektorer

HPGe detectors for gamma spectroscopy

Energy range
Approximately 40 keV and above
Relative efficiency
10–150% across the model series; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.80–1.30 keV for GEM10–GEM150; model-dependent
17 models
Safeguards planar HPGe-detektor
ORTEC

Safeguards planar HPGe-detektor

Planar HPGe gamma detector

Detector type
Planar HPGe
Energy resolution at 122 keV
Warranted FWHM for SGD-16550P4: 550 eV at 1 kcps, 6 μs; 615 eV at 50 kcps, 1 μs
7 models
GLP plana HPGe-detektorer
ORTEC

GLP plana HPGe-detektorer

HPGe gamma detector

Energy range
Approximately 5–300 keV
Active area
Nominally 80–1,000 mm², model-dependent
Energy resolution at 122 keV
FWHM maximum limits 0.51–0.63 keV for the tabulated models
8 models
GWL brunnsdetektorer
ORTEC

GWL brunnsdetektorer

HPGe gamma detector

Detector type
P-type reverse coaxial HPGe well detector
Energy range
Approximately 10 keV–10 MeV
28 models
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.