ORTEC 2BY2/3BY3

Integrated 2 × 2 and 3 × 3 in NaI(Tl) probes for field spectroscopy

Complete NaI(Tl) probes for in-field gamma spectroscopy: crystal, photomultiplier and PMT base with integral preamplifier and high voltage in a rugged aluminium housing. A single cable carries both power and signal; the DD versions connect directly to the digiDART or digiDART-LF.

Detector type
NaI(Tl) crystal with photomultiplier and PMT base with integral preamplifier and HV supply, in an aluminium housing1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Low power (240 mW) – suited to portable systems
  • Active bias network for high-rate operation with minimal peak shift
  • Optional break-out adapter for a BNC signal (296-ADAPT)

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector typeNaI(Tl) crystal with photomultiplier and PMT base with integral preamplifier and HV supply, in an aluminium housing1
Crystal dimensions2 × 2 in (2BY2, 2BY2-DD) or 3 × 3 in (3BY3, 3BY3-DD)1
PMT base296 ScintiPack with low-power adjustable high-voltage supply, active bias network and charge-sensing preamplifier1
Power supply2BY2/3BY3: +12 V at 20 mA (240 mW) via a captive cord with a standard preamplifier power plug (9-pin D), nominally 3 m1
Compatible instrumentsDD versions: directly to the digiDART and digiDART-LF (also other ORTEC DSP spectrometers); 2BY2/3BY3: amplifiers with a standard preamplifier power connector1
Net weight2BY2/2BY2-DD: 2.5 kg; 3BY3/3BY3-DD: 4 kg1
Dimensions2BY2/2BY2-DD: 35.5 cm long × Ø7.62 cm; 3BY3/3BY3-DD: 38.9 cm long × Ø10.2 cm1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ORTEC (AMETEK)Product page More Information – Everything You Need in One Compact Package; Ordering Information; More Information – Ultra Low Power; Specifications – Power Required … Checked 2026-10-16
digiDART
ORTEC

digiDART

Portable digital MCA

Compatible detectors
SMART-1 HPGe detectors; other detectors via a Detector Interface Module (DIM)
Spectrum channels
512–16 k
1 model
digiDART-LF
ORTEC

digiDART-LF

Portable MCA for scintillation detectors

Detector type
NaI(Tl) and scintillators such as LaBr₃
Spectrum channels
512–2 k, software selectable
14 referenced values
ORTEC LABR
ORTEC

ORTEC LABR

LaBr₃(Ce) scintillation detectors with better resolution than NaI(Tl)

Detector type
LaBr₃(Ce) scintillator with 14-pin photomultiplier
Energy resolution
Per the ordering information: LABR-1x1 3.5% guaranteed; LABR-1.5x1.5 3.0% (target); LABR-2x2 and LABR-3x3 3.5% (target)
8 referenced values
ORTEC 905 Series
ORTEC

ORTEC 905 Series

NaI(Tl) scintillation detectors, 1 × 1 to 4 × 4 in

Detector type
NaI(Tl) scintillator with photomultiplier tube
Typical energy resolution, Cs-137
About 7% for a 3 in diameter by 3 in long crystal, slightly worse for larger sizes (manufacturer’s general figure for NaI(Tl))
5 referenced values