FoodGuard-1

NaI-based system for rapid food screening

Ready-to-use system for rapid screening of solid and liquid foodstuffs for radioactive contamination, aimed at food producers, traders and import and export agencies. A 3 × 3 in NaI detector in a lead shield and a USB-connected digiBASE measure samples in 1-litre Marinelli beakers; the software checks the results against allowable limits, raises alarms and prints the report. Supplied pre-calibrated, battery operated and transportable on a cart.

Detector type
NaI(Tl) 3 × 3 in (ORTEC 905-4) with digiBASE: 14-pin PMT base with integrated bias supply, preamplifier and digital MCA1
Typical energy resolution, Cs-137
8% at 662 keV1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Results as percentage of maximum permitted concentration (MPC) with audible alarms
  • Digitally stabilised against temperature variations
  • Supplied pre-calibrated with sample containers and a check source

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeNaI(Tl) 3 × 3 in (ORTEC 905-4) with digiBASE: 14-pin PMT base with integrated bias supply, preamplifier and digital MCA1
Monitored nuclides¹³¹I, ¹⁰³Ru, ¹³⁴Cs and ¹³⁷Cs; total caesium (¹³⁴Cs + ¹³⁷Cs) can be reported; naturally occurring ⁴⁰K is reported to monitor system performance1
Sample geometry1-litre Marinelli beakers (GA-MA 133N-E with lid), six included1

Performance

Typical energy resolution, Cs-1378% at 662 keV1

Software & data

Analysis method“Interference ROI matrix”, approved by the US FDA for monitoring foodstuffs; results as percentage of maximum permitted concentration (MPC) with audible alarm at a user-set limit1

Connectivity & interface

CommunicationUSB 2.0 (12 Mbps); the digiBASE is powered from the USB cable1

Environment & ratings

Listed operating systemWindows XP Professional SP3 or Windows 71

Ordering & accessories

Included softwareFoodGuard-1 v2.0 (FG-1-BW) in English, Russian, Chinese and Japanese; MAESTRO for spectrum display and calibration1
AccessoriesFGCART transport cart (24 × 24 in base, 36 in high, locking wheels); additional Marinelli beakers (FG-1-MARINELLI-CASE, 33 pcs)1
ModelsFOODGUARD-1 (base system), FOODGUARD-1-PC (with laptop and printer), FOODGUARD-1-CART (with cart), FOODGUARD-1-PC-CART (with computer, printer and cart)1

General

Lead shieldingBench-top low-background lead shield, 30 mm (G5-FOODGUARD-1), accommodates a 1-litre Marinelli beaker1
CalibrationSupplied pre-calibrated for gain and efficiency; gain is stabilised on the ⁴⁰K peak from a small KCl sample inside the shield; a check source of approx. 2 kg KCl is included1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ORTEC (AMETEK)Product page Specifications – Hardware; Ordering Information; Specifications – Hardware; More Information; Specifications – Software; Overview; Principle of Operation … Checked 2026-10-16
FoodGuard-2
ORTEC

FoodGuard-2

HPGe workstation for quantitative determination of radionuclides in food

Detector type
High-resolution HPGe detector
Relative efficiency
20–60%; detector and cooling chosen when ordering
9 referenced values
digiBASE
ORTEC

digiBASE

MCA and PMT base for nai(tl)

Detector type
NaI(Tl) scintillation detectors
Spectrum channels
1,024
Weight
280 g, digiBASE only
12 referenced values
ORTEC 905 Series
ORTEC

ORTEC 905 Series

NaI(Tl) scintillation detectors, 1 × 1 to 4 × 4 in

Detector type
NaI(Tl) scintillator with photomultiplier tube
Typical energy resolution, Cs-137
About 7% for a 3 in diameter by 3 in long crystal, slightly worse for larger sizes (manufacturer’s general figure for NaI(Tl))
5 referenced values
PINS3-CW-G2
ORTEC

PINS3-CW-G2

Chemical identification with a neutron generator – no ²⁵²Cf or liquid nitrogen

Relative efficiency
>50% typical (ANSI/IEEE 325-1996)
Energy resolution at 122 keV
<1600 eV FWHM (warranted at optimum settings and depending on detector type)
Energy resolution at 1.33 MeV
≤2.5 keV FWHM at 1,332 keV (warranted at optimum settings and depending on detector type)
14 referenced values