Shallow Hole Probe
HPGe gamma detector
- Detector type
- Configured with GEM, GMX, GLP, PROFILE or Safeguards HPGe
- Weight
- Approximately 12 lb
- LN₂ holding time
- Approximately 16 hours with 70 mm endcap

Bild: ORTEC
HPGe detector cooling
Liquid nitrogen cooling with fewer refills. Möbius recondenses nitrogen to simplify operation of your laboratory HPGe detector.
Download product sheet (PDF)All values with references – for tender documents
Specifications checked against the manufacturer’s documents on 2026-10-16
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.
| Audible noise | <60 dBA at 1 m and ambient <30 °C1 |
|---|
| Cooling technology | LN₂ recondensation with Sunpower cooler1 |
|---|---|
| Dewar capacity | 25 litres, excluding detector dipstick volume1 |
| LN₂ hold time during power loss | Full dewar, typical detector: Streamline about 7–10 days; PopTop about 4–7 days1 |
| LN₂ loss with cooler off | Approximately 3 litres per day2 |
| Weight | 28.58 kg empty; 51.26 kg full, excluding cryostat and detector1 |
|---|
| Refill interval | 2 years or longer under uninterrupted steady-state operation after cooldown and topping off1 |
|---|---|
| Level monitoring | Continuous 0–100% measurement; warning below 70%1 |
| Maintenance | Easily removable, washable air inlet filter; no other maintenance required2 |
| UPS operation | Power-loss input disables cryocooler; onboard computer and diagnostics may run on a small UPS2 |
The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.
4 models in the series. Filter or scroll the table to compare.
| Model | Cryostat configuration | Ordering condition | Included collar and clamp2 |
|---|---|---|---|
| CFG-PS4-MOBIUS-B | PopTop; side-looking cryostat with Möbius Recycler3 | Available standalone; -DET denotes purchase together with a detector2 | – |
| MOBIUS-B | Side-mounted; CFG-HJ or CFG-SJ J-style cryostat, or CFG-SL side-looking cryostat2 | May only be purchased with a detector and a CFG-HJ, CFG-SJ or CFG-SL cryostat; retrofitting an existing detector requires returning it to the factory2 | – |
| MOBIUS-PT | PopTop; CFG-PH4 horizontal or CFG-PV4 vertical dipstick cryostat2 | MOBIUS-PT; MOBIUS-PT-DET when purchased together with a PopTop detector and a CFG-PV4 or CFG-PH4 dipstick cryostat2 | 38.1 mm (1.5 inch), CLAMP-1.50 |
| MOBIUS-ST | Streamline; CFG-SH/CFG-N-SH horizontal or CFG-SV vertical dipstick cryostat2 | Available standalone; -DET denotes purchase together with a detector3 | 31.75 mm (1.25 inch), CLAMP-1.25 |
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

HPGe gamma detector

HPGe detector cooling

Mechanical cooling for HPGe
We help you choose the right configuration, detector and accessories for your measurement task.