ORTEC 905 Series

NaI(Tl) scintillation detectors, 1 × 1 to 4 × 4 in

NaI(Tl) scintillation detectors with photomultiplier tubes in four sizes, from 1 × 1 to 4 × 4 in. The detectors are assembled and supplied to ORTEC by companies that specialise in NaI(Tl) detectors, and specifications may vary slightly depending on the original manufacturer. Special configurations such as well detectors and thyroid counters are available on special order.

Detector type
NaI(Tl) scintillator with photomultiplier tube1
Typical energy resolution, Cs-137
About 7% for a 3 in diameter by 3 in long crystal, slightly worse for larger sizes (manufacturer’s general figure for NaI(Tl))1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector typeNaI(Tl) scintillator with photomultiplier tube1
Crystal dimensions905-1: 1 × 1 in (2 in PMT); 905-3: 2 × 2 in (2 in PMT); 905-4: 3 × 3 in (3 in PMT); 905-16: 4 × 4 in (3 in PMT)1
Typical energy resolution, Cs-137About 7% for a 3 in diameter by 3 in long crystal, slightly worse for larger sizes (manufacturer’s general figure for NaI(Tl))1
Special configurationsWells, thin-window X-ray, thyroid counters and large slabs on special order1
AccessoriesLead Shield G-5, table-top shield with cable-way and clamp for the detector/PMT; not compatible with the 905-161

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ORTEC (AMETEK)Product page Ordering Information; Overview; Specifications Checked 2026-10-16
ORTEC LABR
ORTEC

ORTEC LABR

LaBr₃(Ce) scintillation detectors with better resolution than NaI(Tl)

Detector type
LaBr₃(Ce) scintillator with 14-pin photomultiplier
Energy resolution
Per the ordering information: LABR-1x1 3.5% guaranteed; LABR-1.5x1.5 3.0% (target); LABR-2x2 and LABR-3x3 3.5% (target)
8 referenced values
ORTEC 2BY2/3BY3
ORTEC

ORTEC 2BY2/3BY3

Integrated 2 × 2 and 3 × 3 in NaI(Tl) probes for field spectroscopy

Detector type
NaI(Tl) crystal with photomultiplier and PMT base with integral preamplifier and HV supply, in an aluminium housing
7 referenced values
INNOPROBE
ORTEC

INNOPROBE

Alpha/beta probe for the RADEAGLET-R

Detector type
Alpha/beta-sensitive scintillator with photomultiplier (ZnS:Ag)
Count-rate range
Up to 25 kcps alpha and 20 kcps beta
Weight
300 g (0.66 lb)
15 referenced values
PM-33 Detector
Rotem

PM-33 Detector

Highly sensitive 3 × 3 inch NaI(Tl) probe for environmental gamma monitoring

Energy range
Gamma above 50 keV
Measurement range
Stand-alone: background to 10 µSv/h; as environmental monitor with the TeleMeter: background to 15 mSv/h
Count-rate range
0–50,000 cps
9 referenced values