FoodGuard-2-AK

Add-on kit that turns a GammaVision system into a FoodGuard-2 station

Add-on kit for existing ORTEC gamma spectrometry systems running GammaVision. It installs in minutes without affecting the GammaVision system and, once calibrated, gives the full features of the FoodGuard-2 for measuring gamma-emitting radioactivity in food, water and agricultural samples. The kit includes the software, Marinelli beakers and a KCl check source.

Required combination
Existing ORTEC gamma spectrometry system running GammaVision under Windows XP or Windows 7 (32-bit)1
Contents
FoodGuard-2 software (FG-2-B32, version 1.0.11 or later), CONNECTIONS upgrade (797230, version 7.02.03 or later), 6 × 2-litre Marinelli beakers and check source (2-litre Marinelli beaker filled with KCl, ⁴⁰K)1
Detector requirement
The beakers suit HPGe detectors with an endcap diameter of 83 mm or less1
Cs-137 MDC
Typical system with a 20% detector and 2-litre Marinelli beakers of liquid: 0.75 Bq/L in 10 minutes, 0.5 Bq/L in 30 minutes (ISO 11929; not guaranteed on any specific system)1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Required combinationExisting ORTEC gamma spectrometry system running GammaVision under Windows XP or Windows 7 (32-bit)1
ContentsFoodGuard-2 software (FG-2-B32, version 1.0.11 or later), CONNECTIONS upgrade (797230, version 7.02.03 or later), 6 × 2-litre Marinelli beakers and check source (2-litre Marinelli beaker filled with KCl, ⁴⁰K)1
Detector requirementThe beakers suit HPGe detectors with an endcap diameter of 83 mm or less1
Cs-137 MDCTypical system with a 20% detector and 2-litre Marinelli beakers of liquid: 0.75 Bq/L in 10 minutes, 0.5 Bq/L in 30 minutes (ISO 11929; not guaranteed on any specific system)1
AlarmConfigurable alarms when activity level, percentage or sum of activities is exceeded; editable limits tables derived from international standards (examples from e.g. the US FDA and WHO)1
ReportingCustomizable reports in HTML and PDF format1
OptionsANGLE-BW, advanced efficiency calibration software for HPGe detectors1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ORTEC (AMETEK)Product page Overview; System Prerequisites; What is in a FoodGuard-2-AK Add-On Kit?; System Minimum Detectable Concentration; Overview; More Information … Checked 2026-10-16
FoodGuard-2
ORTEC

FoodGuard-2

HPGe workstation for quantitative determination of radionuclides in food

Detector type
High-resolution HPGe detector
Relative efficiency
20–60%; detector and cooling chosen when ordering
9 referenced values
GammaVision
ORTEC

GammaVision

Gamma spectroscopy software

Spectrum channels
Up to 64 k
10 referenced values
ANGLE
ORTEC

ANGLE

ORTEC measurement and analysis software

Primary function
Gamma-spectroscopy efficiency calculation and calibration transfer
Measurement systems
HPGe, Ge(Li) and NaI; coaxial, planar and well configurations as applicable
Calculation method
Efficiency Transfer with Monte Carlo modelling in ANGLE5
10 referenced values
Vista FC
ORTEC

Vista FC

Alpha/beta counter control software for health physics

Primary function
Control software for health-physics sample counting with the WPC-9550 and other compatible systems
Sample parameters
Input of e.g. air volume and liquid volume
Access control
Password-protected instrument setup
5 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.