Exempt Quantity Radioactive Sources

Check sources for energy calibration in 2.5 cm plastic disks

Small radioactive check sources for energy calibration, mounted in 2.5 cm diameter sealed plastic disks. The activities are within the exempt quantities of the US USNRC 30.71 Schedule B. The sources are manufactured by Spectrum Techniques in Oak Ridge and sold by ORTEC in sets of three, five or eight sources.

Use
Check sources for energy calibration1
Format
Sealed plastic disks, 2.5 cm diameter1
Licensing
Exempt from USNRC and US State licensing; no special storage or disposal requirements there1
Source manufacturer
Spectrum Techniques, Oak Ridge (USA)1

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

UseCheck sources for energy calibration1
FormatSealed plastic disks, 2.5 cm diameter1
LicensingExempt from USNRC and US State licensing; no special storage or disposal requirements there1
Source manufacturerSpectrum Techniques, Oak Ridge (USA)1
Available nuclides¹³³Ba, ¹⁰⁹Cd, ¹³⁷Cs, ⁵⁷Co, ⁶⁰Co, ⁵⁴Mn, ²¹⁰Po, ²²Na, ⁹⁰Sr, ²⁰⁴Tl, ⁶⁵Zn and ²¹⁰Pb; standard activity 0.1–5 µCi per source1
Source sets outside the USARSS3UN: ²¹⁰Po 0.1, ⁹⁰Sr 0.1 and ⁶⁰Co 0.5 µCi; RSS5EU: ²¹⁰Po 0.1, ⁹⁰Sr 0.1, ²⁰⁴Tl 0.25, ⁶⁰Co 1 and ¹³⁷Cs 0.25 µCi; RSS8UN: ¹³³Ba, ¹⁰⁹Cd, ⁵⁷Co, ⁶⁰Co, ²²Na and ⁶⁵Zn 1 µCi each, ¹³⁷Cs 0.1 and ¹⁵²Eu 0.5 µCi; RSS8EU: as RSS8UN but ¹³⁷Cs 0.25 µCi1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ORTEC (AMETEK)Product page Overview; Chart of Radioactive Decay; Ordering Information – Non-U.S. Customers Checked 2026-10-16
ORTEC Am-1C
ORTEC

ORTEC Am-1C

Alpha calibration source

Radionuclide
²⁴¹Am
Nominal activity
0.1 µCi
Calibration
Within 1 % of absolute disintegration rate
8 referenced values
Alfa- och betakällor
Orano LEA

Alfa- och betakällor

Calibration sources

Radiation
Alpha or beta
Source formats
Point sources and wide areas: discs, planchets, rectangles or squares
Use
Calibration of alpha spectrometers and contamination monitors
10 models
Medicinska kalibreringskällor
Orano LEA

Medicinska kalibreringskällor

Medical equipment calibration sources

Source form
Sealed sources
Use
Stability, efficiency and homogeneity checks and calibration
Equipment types
SPECT/PET, dose calibrators, well detectors and radiation-protection instruments
11 referenced values
Gasstandarder
Orano LEA

Gasstandarder

Gas calibration standards

Standard radionuclide
Kr-85
Radionuclides on request
For example Xe-133
Packaging
Glass ampoule or metal cylinder
10 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.