digiBASE
MCA and PMT base for nai(tl)
- Detector type
- NaI(Tl) scintillation detectors
- Spectrum channels
- 1,024
- Weight
- 280 g, digiBASE only

Bild: ORTEC
LaBr₃(Ce) scintillation detectors with better resolution than NaI(Tl)
Lanthanum bromide, LaBr₃(Ce), scintillation detectors with high light output and a fast decay time. Compared with NaI(Tl) they give better energy resolution and stability and higher throughput at high count rates; the resolution varies little over a wide range of count rates. Four crystal sizes from 1 × 1 to 3 × 3 in, used with the ORTEC digiBASE, digiDART or NIM electronics.
Download product sheet (PDF)All values with references – for tender documents
Specifications checked against the manufacturer’s documents on 2026-10-17
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.
| Detector type | LaBr₃(Ce) scintillator with 14-pin photomultiplier1 |
|---|---|
| Crystal dimensions | LABR-1x1: 1 × 1 in (1.5 in PMT); LABR-1.5x1.5: 1.5 × 1.5 in (2 in PMT); LABR-2x2: 2 × 2 in (2 in PMT); LABR-3x3: 3 × 3 in (3 in PMT)1 |
| Energy resolution | Per the ordering information: LABR-1x1 3.5% guaranteed; LABR-1.5x1.5 3.0% (target); LABR-2x2 and LABR-3x3 3.5% (target)1 |
| Primary decay time | 0.026 µs (NaI(Tl): 0.230 µs)1 |
| Photoelectron yield relative to NaI | 130 (NaI = 100)1 |
| Dimensions | Detector housing OD × length and overall length (plus pins): LABR-1x1 30.4 × 26.1 mm, 143 mm; LABR-1.5x1.5 43.1 × 39 mm, 151.5 mm; LABR-2x2 55.8 × 51.5 mm, 164 mm; LABR-3x3 82.5 × 157 mm, 194 mm1 |
| Compatible instruments | digiBASE or digiBASE-E (simplest, requires a computer); digiDART or digiDART-LF with DIM-296 (portable); NIM with a 296, 276 or 266 PMT base with 113 preamplifier1 |
| Efficiency relative to NaI(Tl) | About 1.3 times that of NaI(Tl) for the same volume2 |
The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

MCA and PMT base for nai(tl)

Digital MCA in PMT base

Portable MCA for scintillation detectors

NaI(Tl) scintillation detectors, 1 × 1 to 4 × 4 in
We help you choose the right configuration, detector and accessories for your measurement task.