Products

Product catalogue

Search and filter detectors, measurement instruments, electronics and software. Every technical value is taken from the manufacturers’ own documents and referenced to its source.

Not sure what you need? Try the instrument finder
664 products

Products

NewFlint USB
BrightSpec

Flint USB

Integrated gamma probe: SiPM scintillation detector and digital MCA in one housing

Detector type
Scintillator with SiPM; standard round NaI(Tl), 2 × 2 or 3 × 3 in; can be ordered with CsI(Tl), CeBr₃, LaBr₃(Ce), LBC or SrI₂
Spectrum channels
256, 512, 1,024, 2,048 or 4,096, 32-bit depth per channel
13 referenced values
NewLabVision 4 ( LVis )
ORTEC

LabVision 4 ( LVis )

Software · analysis

Primary function
Nuclear spectrometry counting-laboratory management
Analysis engine
GammaVision and the tRAYcy Monte Carlo algorithm
Measurement workflow
Single-detector and automated multi-detector workflows
8 referenced values
SaphyRAD S
Bertin

SaphyRAD S

Dose rate & contamination

Energy range
50 keV–3 MeV
IP rating
IP65
Weight
620 g
13 referenced values
FOOMON
ELSE NUCLEAR

FOOMON

Food monitoring

Detector type
2 × 2 inch NaI(Tl)
Total weight
Approximately 22 kg
IP rating
IP67 during transport with closed lid; IP65 in operating setup
12 referenced values
Model 26 Friskers
Ludlum

Model 26 Friskers

Contamination monitoring

Detector type
Integrated pancake GM
Energy range
16.3 keV–1.3 MeV
Count-rate range
0.1 cps–1.99 kcps; 1 cpm–99.9 kcpm
12 referenced values
H Series
H3D

H Series

Gamma imaging

Detector type
CZT (CdZnTe)
Spectroscopy energy range
50–3000 keV (H100/H400/H420/H1600)
IP rating
H100/H400/H420/H1600: IP67 (excluding external media)
9 models
Detective DX1
ORTEC

Detective DX1

Portable HPGe spectroscopy

Detector type
P-type coaxial HPGe detector
Energy range
DX1/DX1-N: 40 keV–3 MeV; DX1-8/DX1-8-N: 40 keV–8 MeV
Weight
7.23 kg gamma; 7.87 kg gamma/neutron
4 models
RADEAGLET-R
ORTEC

RADEAGLET-R

Handheld isotope identification

Detector type
NaI(Tl) or LaBr₃(Ce), model dependent
Energy range, NaI
NaI: 15 keV–3 MeV
Spectrum channels
2,048
12 models
Möbius Recycler
ORTEC

Möbius Recycler

HPGe detector cooling

Weight
28.58 kg empty; 51.26 kg full, excluding cryostat and detector
LN₂ hold time during power loss
Full dewar, typical detector: Streamline about 7–10 days; PopTop about 4–7 days
4 models
GEM HPGe-detektorer
ORTEC

GEM HPGe-detektorer

HPGe detectors for gamma spectroscopy

Energy range
Approximately 40 keV and above
Relative efficiency
10–150% across the model series; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.80–1.30 keV for GEM10–GEM150; model-dependent
17 models
ModuLab XM MTS materialtestsystem
AMETEK SI

ModuLab XM MTS materialtestsystem

Materials test system

Impedance range
10 µΩ–100 TΩ depending on module configuration
EIS frequency range
10 µHz–1 MHz with XM MFRA 1MHz
Maximum output current
XM MAT: ±100 mA; XM MBST 2A: ±2 A (option)
6 models
ModuLab XM ECS
AMETEK SI

ModuLab XM ECS

Configurable electrochemical system

Compliance voltage
±8 V standard; ±30 V / ±100 V with HV options
8 models
SI-9300R
AMETEK SI

SI-9300R

Battery cycler / analyzer

Measurement channels per module
5 in a fully populated module
Applied voltage per channel
+300 mV to +10 V
Maximum output current
±200 A continuous; 300 A for a 60 s pulse
6 models
PARSTAT MC
AMETEK SI

PARSTAT MC

Modular multichannel system

Measurement channels
Up to 20 with PMC-200; up to 10 with PMC-1000 or PMC-2000A
Compliance voltage
PMC-200: ±10 V; PMC-1000: ±12 V; PMC-2000A: ±30 V
3 models
PAM-100 / PAM-170
Bertin · Bertin VF Nuclear

PAM-100 / PAM-170

Portable activity meters

Detector type
Plastic scintillator and/or ZnS(Ag), variant dependent
Active area
PAM-100: 100 cm²; PAM-170: 170 cm²
20 models
A Series (A400) RIID
H3D

A Series (A400) RIID

Handheld RIID

Detector type
A400: CZT (CdZnTe)
Spectroscopy energy range
A400: 50–3000 keV
Weight
A400: 1.2 kg
6 models
RADEAGLE
ORTEC

RADEAGLE

Handheld isotope identification

Detector type
NaI(Tl) or LaBr₃(Ce), model dependent
Energy range
11 keV–3 MeV
Spectrum channels
2,048
20 models
Ludlum Model 3003
Ludlum

Ludlum Model 3003

SCA and detector readout

Weight excluding detectors and clips
0.9 kg
Enclosure rating and conditions
IP53
5 models
Alfa- och betakällor
Orano LEA

Alfa- och betakällor

Calibration sources

Radiation
Alpha or beta
Source formats
Point sources and wide areas: discs, planchets, rectangles or squares
Use
Calibration of alpha spectrometers and contamination monitors
10 models
RCAP-2 rekylskyddspaket
ORTEC

RCAP-2 rekylskyddspaket

Alpha spectrometry accessory

Models
RCAP-2-120V; RCAP-2-240V
Supply voltage
RCAP-2-120V: 120 V; RCAP-2-240V: 240 V
Sample-holder bias
−12 V
2 models
Alpha Suite alfaspektrometrar
ORTEC

Alpha Suite alfaspektrometrar

Integrated alpha spectrometry

Energy resolution
≤20 keV FWHM with BU-017-450-100 ULTRA detector and ²⁴¹Am point source; detector-to-source spacing equal to detector diameter
Spectrum channels
Software-selectable conversion gain: 256, 512, 1024, 2048 or 4096 channels
19 models
digiDART
ORTEC

digiDART

Portable digital MCA

Compatible detectors
SMART-1 HPGe detectors; other detectors via a Detector Interface Module (DIM)
Spectrum channels
512–16 k
1 model
Showing 24 of 664