Products

MCA, electronics & counters

Digital and analog MCAs, NIM modules, amplifiers and counters.

140 products

Products

NewFlint USB
BrightSpec

Flint USB

Integrated gamma probe: SiPM scintillation detector and digital MCA in one housing

Detector type
Scintillator with SiPM; standard round NaI(Tl), 2 × 2 or 3 × 3 in; can be ordered with CsI(Tl), CeBr₃, LaBr₃(Ce), LBC or SrI₂
Spectrum channels
256, 512, 1,024, 2,048 or 4,096, 32-bit depth per channel
13 referenced values
Ludlum Model 3003
Ludlum

Ludlum Model 3003

SCA and detector readout

Weight excluding detectors and clips
0.9 kg
Enclosure rating and conditions
IP53
5 models
digiDART
ORTEC

digiDART

Portable digital MCA

Compatible detectors
SMART-1 HPGe detectors; other detectors via a Detector Interface Module (DIM)
Spectrum channels
512–16 k
1 model
928 EASY-NIM
ORTEC

928 EASY-NIM

NIM mca, counter and timer

Spectrum channels
512–16,384, software selectable
Weight
0.9 kg net
3 models
DSPEC 50/50A & 502/502A
ORTEC

DSPEC 50/50A & 502/502A

Digital gamma spectrometer / MCA

Spectrum channels
50/502: 512–16 k; 50A/502A: 256–64 k
Weight
DSPEC 50: 11 kg; DSPEC 502: 11.7 kg
4 models
Flint-NaI-Pro
BrightSpec

Flint-NaI-Pro

Gamma acquisition and analysis bundle: Flint probe with NaI(Tl) and bGamma software

Detector type
Flint: SiPM-based integrated probe with a NaI crystal, 2 × 2 or 3 × 3 in
Spectrum channels
256, 512, 1,024, 2,048 or 4,096, 32-bit depth per channel
10 referenced values
bSCAN
BrightSpec

bSCAN

Radio-TLC scanner with NaI(Tl) detector and built-in MCA

Detector type
NaI(Tl), typically 1 × 1 in (2.54 × 2.54 cm)
Spectrum channels
Up to 4,096 (PHA and MCS)
Weight
16.5 kg (36.4 lb)
12 referenced values
bDAS
BrightSpec

bDAS

Digital acquisition system for synchronised counting with up to 12 probes

Weight
Probe: approx. 4 kg
6 referenced values
bPAD 422
BrightSpec

bPAD 422

Digital single-channel analyser in the tube socket with RS422/485, for radiotracer measurements

Weight
Approx. 80 g
8 referenced values
bPAD+VR
BrightSpec

bPAD+VR

bPAD+ with an analogue output for pulses or count rate, e.g. for flow instruments

Operating modes
Differential and integral
Discriminator
Upper and lower level discriminator, 2,048 steps
Gain
×1–×16 (×1–×256 on request)
8 referenced values
ILLUSTRATION
BrightSpec

bPAD+

bPAD with an extra analogue pulse output to an external MCA

Operating modes
Differential and integral
Discriminator
Upper and lower level discriminator, 2,048 steps
Gain
×1–×256
8 referenced values
bPAD
BrightSpec

bPAD

Digital single-channel analyser (SCA) in the tube socket, controlled via USB

Weight
Approx. 90 g
9 referenced values
Topaz-X
BrightSpec

Topaz-X

Compact digital MCA for energy-dispersive X-ray fluorescence (EDXRF)

Weight
Less than 100 g (including box)
Spectrum channels
Up to 16,384, 32-bit depth per channel
11 referenced values
Topaz-SiPM
BrightSpec

Topaz-SiPM

Miniature MCA for scintillators with silicon photomultipliers (SiPM)

Spectrum channels
Up to 4,096
Weight
Less than 70 g (including box)
11 referenced values
Topaz-Pico BNC
BrightSpec

Topaz-Pico BNC

Topaz-Pico with BNC connectors instead of Lemo

Spectrum channels
Up to 4,096
7 referenced values
Topaz-Pico
BrightSpec

Topaz-Pico

Pocket-size stand-alone digital MCA for scintillation detectors

Spectrum channels
Up to 4,096
Weight
Less than 150 g (including box)
10 referenced values
Topaz-HR
BrightSpec

Topaz-HR

Compact stand-alone digital MCA for HPGe and other high-resolution detectors

Spectrum channels
Up to 16,384 (16K), 32-bit depth
Weight
Less than 200 g (including box)
11 referenced values
bMCA-Box
BrightSpec

bMCA-Box

bMCA with an SHV connector instead of the tube socket, for single-connector detectors

Spectrum channels
256, 512, 1,024, 2,048 or 4,096 (PHA and MCS)
Weight
Approx. 120 g
6 referenced values
bMCA-Ethernet
BrightSpec

bMCA-Ethernet

bMCA with Ethernet and PoE instead of USB, for remote installation

Spectrum channels
Up to 4,096
Weight
Approx. 120 g
9 referenced values
bMCA-USB
BrightSpec

bMCA-USB

Compact digital MCA built into the tube socket, for scintillation detectors

Spectrum channels
256, 512, 1,024, 2,048 or 4,096 (PHA and MCS)
Weight
Approx. 92 g
10 referenced values
MPC-9604
ORTEC

MPC-9604

Four-detector alpha/beta counter for high sample throughput

Detector type
Four pancake-style gas-flow proportional detectors, Ø5.7 cm, with cosmic guard detector
Weight
544 kg (shipping 635 kg); the support surface must bear 1,200 lb per unit
21 referenced values
ASC-950-DP-G
ORTEC

ASC-950-DP-G

Automatic gasless alpha/beta counter with sample changer

Detector type
Dual-phosphor scintillator (ZnS + plastic), Ø5.1 cm; gasless operation
Weight
50 samples: 49.9 kg; 100 samples: 54.4 kg
14 referenced values
Showing 24 of 140