MPC-900-DP
Manual single-sample alpha/beta counter with gasless scintillation detector
- Detector type
- Dual-phosphor scintillator (ZnS + plastic), Ø5.1 cm; gasless operation
- Weight
- 40 lb; guard +7 lb; shield +50 lb

Bild: ORTEC
Manual single-sample alpha/beta counter with gas-flow detector
Benchtop gross alpha/beta counters with a hemispherical gas-flow proportional detector, for health physics such as smears and air filters and for radiochemistry when only alpha counting is of interest. The windowless GFL-2 gives higher efficiencies for alpha emitters and higher-activity low-energy beta emitters. Routines and QC charts are programmed in DUO Express and transferred via PIC Link.
Download product sheet (PDF)All values with references – for tender documents
Specifications checked against the manufacturer’s documents on 2026-10-17
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.
| Detector type | Hemispherical gas-flow proportional detector, Ø5.7 cm; windowed or windowless1 |
|---|---|
| Window | GFW-2: aluminised, 80 µg/cm²; GFL-2: windowless1 |
| Sample geometry | Planchets Ø5.1 cm (2 in), 1/8, 1/4 or 5/16 in deep (3.2, 6.3 or 7.9 mm)1 |
| Typical detection efficiency | Top / 1/8″ / 1/4″ / 5/16″ bottom – with window (GFW): ²³⁹Pu 40/32/26/24%, ⁹⁰Sr/Y 55/48/40/37%, ⁹⁹Tc 47/37/30/27%; windowless (GFL): ²³⁹Pu 47/47/47/47%, ⁹⁰Sr/Y 60/62/62/62%, ⁹⁹Tc 58/58/58/58%1 |
|---|---|
| Background rate | Warranted alpha/beta (cpm), both versions: <0.1/<55 without lead; <0.1/<45 with lead1 |
| Sample capacity | 1 sample (manual)1 |
|---|
| Software | DUO Express included; routines and QC charts are programmed on a PC and transferred via PIC Link cable1 |
|---|
| Communication | Data export via USB flash drive and USB PIC Link1 |
|---|---|
| User interface | Touch screen1 |
| Power supply | 110–240 V AC, 50–60 Hz1 |
|---|
| Operating temperature | 10–40 °C1 |
|---|
| Count modes | Alpha only; alpha/beta simultaneously; alpha then beta1 |
|---|---|
| Counting gas | P-10, 60 cc/min at 10 psi; Gas-PRO fail-safe monitoring senses breaches in gas flow1 |
| Use | Health physics such as smears and air filters; radiochemistry when only alpha counting is of interest1 |
The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Manual single-sample alpha/beta counter with gasless scintillation detector

Automatic low-background alpha/beta counter, 50 or 100 samples

Four-detector alpha/beta counter for high sample throughput

Automatic gasless alpha/beta counter with sample changer
We help you choose the right configuration, detector and accessories for your measurement task.