Detective DX1-TS

Portable HPGe spectrometer for in-situ measurements

Portable, all-inclusive high-resolution gamma spectrometer for in-situ measurements. It collects spectra stand-alone in the field or under computer control via USB, Ethernet or Wi-Fi with applications such as MAESTRO-Pro (included), GammaVision and ISOTOPIC. Physically identical to the Detective DX1, but without the automatic isotope identification applications; it can be upgraded at the factory.

Relative efficiency
≥40% typical (ANSI/IEEE 325-1996)1
Energy resolution at 122 keV
≤1630 eV FWHM (warranted at optimum settings)1
Energy resolution at 1.33 MeV
≤2.0 keV FWHM at 1,332 keV (warranted at optimum settings)1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Hardened cryostat: can be switched off and restarted without a full thermal cycle
  • Two hot-swappable batteries
  • Application mirroring on phone, tablet and computer (iOS, Android, Windows)

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeP-type coaxial HPGe detector1

Performance

Relative efficiency≥40% typical (ANSI/IEEE 325-1996)1
Energy resolution at 122 keV≤1630 eV FWHM (warranted at optimum settings)1
Energy resolution at 1.33 MeV≤2.0 keV FWHM at 1,332 keV (warranted at optimum settings)1
Peak shape FW.1M/FWHM1.9 typical (FWTM/FWHM)1

Electronics & signal

Spectrum channelsUp to 16 k1

Cooling

CoolingStirling cooler with hardened cryostat; cool-down typically 6 hours at 25 °C1

Connectivity & interface

Display5-inch IPS TFT-LCD (800 × 480 pixels), sunlight readable, capacitive multi-touch for finger or stylus1
Data storageInternal RAM and removable low-profile USB flash drive; the supplied drive stores over 100,000 spectra1
CommunicationUSB, Ethernet (RJ45, 10/100 Mbps) and Wi-Fi (IEEE 802.11a/b/g/e/i/h/j/n, WPA/WPA2); remote control from ORTEC CONNECTIONS applications via Mobile MCB Server1

Power & battery

Battery lifeApproximately 8 hours at 25 °C with cold HPGe detector1
Batteries2 rechargeable Li-ion batteries, 98 Wh each nominal; charging time under 4 hours; optional external military battery (Model 2590) extends life to >16 h1
Power supply12–17 V DC from battery or DC supply (universal mains supply included); under 100 W during cool-down and charging, under 35 W cold with fully charged battery1

Mechanical

Detector dimensionsNominally Ø65 × 50 mm1
Weight7.23 kg (15.95 lb)1
DimensionsMax. 39.5 × 14.3 × 23.2 cm (L × W × H) including handle and Ge detector endcap1

Environment & ratings

Operating temperature−20 to +50 °C1
Humidity95%, non-condensing1
IP ratingIP65, sealed against dust and water1

Ordering & accessories

Included softwareMAESTRO-Pro; the isotope identification applications (EasyID, Sleuth and RAPiD) are not included1

General

File formatsANSI/IEEE N42.421
UpgradeFactory upgrade to the Detective DX1 3 MeV or 8 MeV model, with isotope identification and dose-rate calibration1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ORTEC (AMETEK)Brochure p. 5, Technical Specifications – Detector/Cooler; p. 5, Technical Specifications – Digital MCA and Data Processor; p. 5, Technical Specifications; p. 5, Technical Specifications – Physical … Checked 2026-10-16
Detective DX1
ORTEC

Detective DX1

Portable HPGe spectroscopy

Detector type
P-type coaxial HPGe detector
Energy range
DX1/DX1-N: 40 keV–3 MeV; DX1-8/DX1-8-N: 40 keV–8 MeV
Weight
7.23 kg gamma; 7.87 kg gamma/neutron
4 models
IDM-200-V
ORTEC

IDM-200-V

Interchangeable HPGe detector module for measurement systems

Relative efficiency
>50% typical (ANSI/IEEE 325-1996)
Energy resolution at 122 keV
≤1400 eV FWHM (warranted at optimum settings)
Energy resolution at 1.33 MeV
≤2.3 keV FWHM at 1,332 keV (warranted at optimum settings)
24 referenced values
GEM HPGe-detektorer
ORTEC

GEM HPGe-detektorer

HPGe detectors for gamma spectroscopy

Energy range
Approximately 40 keV and above
Relative efficiency
10–150% across the model series; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.80–1.30 keV for GEM10–GEM150; model-dependent
17 models
digiDART
ORTEC

digiDART

Portable digital MCA

Compatible detectors
SMART-1 HPGe detectors; other detectors via a Detector Interface Module (DIM)
Spectrum channels
512–16 k
1 model