digiDART-LF

Portable MCA for scintillation detectors

Portable multichannel analyzer for NaI(Tl) and other scintillation detectors. Its built-in display and keypad allow measurements to be monitored without a connected computer.

Detector type
NaI(Tl) and scintillators such as LaBr₃1
Spectrum channels
512–2 k, software selectable1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-16

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • 2 k channels and internal storage of more than 150 spectra.
  • Nuclide identification and activity calculation for up to nine ROIs.
  • Battery operation and built-in display for use without a connected computer.

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeNaI(Tl) and scintillators such as LaBr₃1

Performance

Maximum throughput>100,000 cps1

Electronics & signal

Spectrum channels512–2 k, software selectable1
Digital filter rise time0.8–20 µs, 0.2 µs steps1

Connectivity & interface

Display240 × 160 pixels, backlit LCD with live spectrum1
Spectrum storageMore than 150 spectra at 2 k channels1
CommunicationUSB1

Power & battery

Battery lifeUp to 12 hours with a fully charged Sony NP-F960 battery and standard ORTEC resistive-feedback preamplifier1
Power supplyLithium-ion camcorder battery, Sony NP-F960 (7.2 V, 38.8 Wh); wall-mounted DC supply +12 V DC, <1.25 A (charging circuitry internal)1

Mechanical

Dimensions20.32 × 12.7 × 7.62 cm1
WeightLess than 900 g (DIM: less than 240 g)2

Environment & ratings

Operating temperature−10 to +60 °C, including LCD1

General

Operation without PCAcquisition and spectrum display without connected PC1
Activity calculationActivity and uncertainty for up to 9 user-defined ROIs1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ORTEC (AMETEK)Product page More Information; Radiation Detector High Voltage Supplies; Specifications tab – System Conversion Gain; Specifications tab – Display; Highlights; digiDART-LF Display and Keypad … Checked 2026-10-16
  2. 2
    Publisher: ORTEC (AMETEK)Manual Manual, section 7.1.1 Electrical and Mechanical Checked 2026-10-16
digiDART
ORTEC

digiDART

Portable digital MCA

Compatible detectors
SMART-1 HPGe detectors; other detectors via a Detector Interface Module (DIM)
Spectrum channels
512–16 k
1 model
928 EASY-NIM
ORTEC

928 EASY-NIM

NIM mca, counter and timer

Spectrum channels
512–16,384, software selectable
Weight
0.9 kg net
3 models
DSPEC 50/50A & 502/502A
ORTEC

DSPEC 50/50A & 502/502A

Digital gamma spectrometer / MCA

Spectrum channels
50/502: 512–16 k; 50A/502A: 256–64 k
Weight
DSPEC 50: 11 kg; DSPEC 502: 11.7 kg
4 models
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.