Safeguards planar HPGe-detektor
Planar HPGe gamma detector
- Detector type
- Planar HPGe
- Energy resolution at 122 keV
- Warranted FWHM for SGD-16550P4: 550 eV at 1 kcps, 6 μs; 615 eV at 50 kcps, 1 μs

Bild: ORTEC
HPGe detectors for gamma spectroscopy
P-type coaxial germanium detectors for laboratory measurements from approximately 40 keV and above. Select a configuration for the sample geometry and measurement task.
Download product sheet (PDF)All values with references – for tender documents
Specifications checked against the manufacturer’s documents on 2026-10-16
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.
| Detector type | P-type coaxial HPGe1 |
|---|
| Relative efficiency | 10–150% across the model series; higher on request2 |
|---|---|
| Energy resolution at 122 keV | FWHM maximum limits 0.80–1.30 keV for GEM10–GEM150; model-dependent2 |
| Energy resolution at 1.33 MeV | FWHM maximum limits 1.7–2.3 keV for GEM10–GEM150; model-dependent2 |
| Resolution measurement conditions | Total system resolution measured at the factory per ANSI/IEEE Std 325-1996, at optimal shaping time with an ORTEC DSPEC-50A2 |
| Energy range | Approximately 40 keV and above1 |
|---|
| Preamplifier | Optional PLUS for high count rates1 |
|---|
| Cooling | LN₂ or compatible mechanical cooling, by configuration1 |
|---|
| Endcap | Low-background carbon fibre option1 |
|---|
| Cryostat configurations | PopTop or Streamline1 |
|---|---|
| Bias control | SMART-1 (-SMP), optional1 |
| Cooling and accessories | Cryostat and dewar or other cooling device required for operation and not included with the detector; a cryostat must be ordered with a Streamline detector2 |
The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.
17 models in the series. Filter or scroll the table to compare.
| Model | Relative efficiency2 | Energy resolution at 122 keV2 | Energy resolution at 1.33 MeV2 | Peak-to-Compton ratio2 | Peak shape FW.1M/FWHM2 | Peak shape FW.02M/FWHM2 | Endcap diameter2 | Ordering configurations2 |
|---|---|---|---|---|---|---|---|---|
| GEM10 | 10 % (minimum) | ≤ 0.80 keV FWHM | ≤ 1.7 keV FWHM | ≥ 41:1 | 1.9 (maximum) | 2.6 (typical) | 70 mm (nominal) | GEM10P4-70 (PopTop) / GEM10-70 (Streamline) |
| GEM15 | 15 % (minimum) | ≤ 0.82 keV FWHM | ≤ 1.8 keV FWHM | ≥ 46:1 | 1.9 (maximum) | 2.6 (typical) | 70 mm (nominal) | GEM15P4-70 (PopTop) / GEM15-70 (Streamline) |
| GEM20 | 20 % (minimum) | ≤ 0.82 keV FWHM | ≤ 1.8 keV FWHM | ≥ 52:1 | 1.9 (maximum) | 2.6 (typical) | 70 mm (nominal) | GEM20P4-70 (PopTop) / GEM20-70 (Streamline) |
| GEM25 | 25 % (minimum) | ≤ 0.82 keV FWHM | ≤ 1.8 keV FWHM | ≥ 56:1 | 1.9 (maximum) | 2.6 (typical) | 76 mm (nominal) | GEM25P4-76 (PopTop) / GEM25-76 (Streamline) |
| GEM30 | 30 % (minimum) | ≤ 0.85 keV FWHM | ≤ 1.8 keV FWHM | ≥ 60:1 | 1.9 (maximum) | 2.6 (typical) | 76 mm (nominal) | GEM30P4-76 (PopTop) / GEM30-76 (Streamline) |
| GEM40 | 40 % (minimum) | ≤ 0.87 keV FWHM | ≤ 1.8 keV FWHM | ≥ 64:1 | 1.9 (maximum) | 2.6 (typical) | 76 mm (nominal) | GEM40P4-76 (PopTop) / GEM40-76 (Streamline) |
| GEM50 | 50 % (minimum) | ≤ 0.90 keV FWHM | ≤ 1.9 keV FWHM | ≥ 66:1 | 1.9 (maximum) | 2.6 (typical) | 83 mm (nominal) | GEM50P4-83 (PopTop) / GEM50-83 (Streamline) |
| GEM60 | 60 % (minimum) | ≤ 1.00 keV FWHM | ≤ 1.9 keV FWHM | ≥ 70:1 | 1.9 (maximum) | 3.0 (typical) | 95 mm (nominal) | GEM60P4-95 (PopTop) / GEM60-95 (Streamline) |
| GEM70 | 70 % (minimum) | ≤ 1.00 keV FWHM | ≤ 2.0 keV FWHM | ≥ 75:1 | 2.0 (maximum) | 3.0 (typical) | 95 mm (nominal) | GEM70P4-95 (PopTop) / GEM70-95 (Streamline) |
| GEM80 | 80 % (minimum) | ≤ 1.10 keV FWHM | ≤ 2.0 keV FWHM | ≥ 77:1 | 2.0 (maximum) | 3.0 (typical) | 95 mm (nominal) | GEM80P4-95 (PopTop) / GEM80-95 (Streamline) |
| GEM90 | 90 % (minimum) | ≤ 1.20 keV FWHM | ≤ 2.0 keV FWHM | ≥ 80:1 | 2.0 (maximum) | 3.0 (typical) | 95 mm (nominal) | GEM90P4-95 (PopTop) / GEM90-95 (Streamline) |
| GEM100 | 100 % (minimum) | ≤ 1.20 keV FWHM | ≤ 2.1 keV FWHM | ≥ 83:1 | 2.0 (maximum) | 3.0 (typical) | 95 mm (nominal) | GEM100P4-95 (PopTop) / GEM100-95 (Streamline) |
| GEM110 | 110 % (minimum) | ≤ 1.30 keV FWHM | ≤ 2.1 keV FWHM | ≥ 85:1 | 2.0 (maximum) | 3.0 (typical) | 95 mm (nominal) | GEM110P4-95 (PopTop) / GEM110-95 (Streamline) |
| GEM120 | 120 % (minimum) | ≤ 1.30 keV FWHM | ≤ 2.1 keV FWHM | ≥ 86:1 | 2.0 (maximum) | 3.1 (typical) | 108 mm (nominal) | GEM120P4-108 (PopTop) / GEM120-108 (Streamline) |
| GEM130 | 130 % (minimum) | ≤ 1.30 keV FWHM | ≤ 2.1 keV FWHM | ≥ 90:1 | 2.0 (maximum) | 3.1 (typical) | 108 mm (nominal) | GEM130P4-108 (PopTop) / GEM130-108 (Streamline) |
| GEM140 | 140 % (minimum) | ≤ 1.30 keV FWHM | ≤ 2.2 keV FWHM | ≥ 90:1 | 2.0 (maximum) | 3.1 (typical) | 108 mm (nominal) | GEM140P4-108 (PopTop) / GEM140-108 (Streamline) |
| GEM150 | 150 % (minimum) | ≤ 1.30 keV FWHM | ≤ 2.3 keV FWHM | ≥ 90:1 | 2.0 (maximum) | 3.1 (typical) | 108 mm (nominal) | GEM150P4-108 (PopTop) / GEM150-108 (Streamline) |
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Planar HPGe gamma detector

HPGe gamma detector

HPGe gamma detector

HPGe gamma detector
We help you choose the right configuration, detector and accessories for your measurement task.