ORTEC Am-1C

Alpha calibration source

ORTEC Am-1C — ²⁴¹Am.

Radionuclide
²⁴¹Am1
Nominal activity
0.1 µCi1
Calibration
Within 1 % of absolute disintegration rate1
Main alpha energy
5.486 MeV (85 %)1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-16

Manufacturer’s product page (opens in a new tab)

Overview

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Radionuclide²⁴¹Am1
Nominal activity0.1 µCi1
CalibrationWithin 1 % of absolute disintegration rate1
Main alpha energy5.486 MeV (85 %)1
Nominal active diameter3 mm1
SubstratePlatinum, 0.127 mm thick; 12.7 mm diameter1
Equivalent source thickness<8 keV1
HolderStainless steel, 6.35 mm thick; 17.46 mm outside diameter1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ORTEC (AMETEK)Brochure p. 1, "Calibrated 241Am Source"; p. 1, Specifications Checked 2026-10-16
ILLUSTRATION
ORTEC

Exempt Quantity Radioactive Sources

Check sources for energy calibration in 2.5 cm plastic disks

Use
Check sources for energy calibration
Format
Sealed plastic disks, 2.5 cm diameter
Licensing
Exempt from USNRC and US State licensing; no special storage or disposal requirements there
6 referenced values
Alfa- och betakällor
Orano LEA

Alfa- och betakällor

Calibration sources

Radiation
Alpha or beta
Source formats
Point sources and wide areas: discs, planchets, rectangles or squares
Use
Calibration of alpha spectrometers and contamination monitors
10 models
Medicinska kalibreringskällor
Orano LEA

Medicinska kalibreringskällor

Medical equipment calibration sources

Source form
Sealed sources
Use
Stability, efficiency and homogeneity checks and calibration
Equipment types
SPECT/PET, dose calibrators, well detectors and radiation-protection instruments
11 referenced values
Gasstandarder
Orano LEA

Gasstandarder

Gas calibration standards

Standard radionuclide
Kr-85
Radionuclides on request
For example Xe-133
Packaging
Glass ampoule or metal cylinder
10 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.