CSS-D-60 Compton Suppression System

Compton-suppressed HPGe system for low-background counting

Complete system for very low-background gamma spectrometry. An NaI guard detector around the HPGe detector records photons scattered out of the germanium crystal, and coincident events are rejected so that the Compton continuum is reduced. This improves the minimum detectable activity, particularly for small samples such as air filters and petri dishes.

Detector type
N-type HPGe (GMX) with carbon-fibre endcap, max. Ø83 mm (3.25 in), and low-background Al cup1
Relative efficiency
60% by default; other detector sizes up to 60% as options1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Digital version with the DSPEC-502A – no NIM rack needed
  • Optional cosmic veto with a plastic scintillator
  • Custom detectors, annulus and shielding on request

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeN-type HPGe (GMX) with carbon-fibre endcap, max. Ø83 mm (3.25 in), and low-background Al cup1
Guard detector9 × 9 in NaI annulus (3.5 in I.D., 10.75 in O.D., FWHM ≤11% at 662 keV) and 6 × 2 in NaI plug (FWHM ≤7% at 662 keV)1

Performance

Relative efficiency60% by default; other detector sizes up to 60% as options1
Peak-to-Compton ratio1300:1 or greater (guaranteed, with the default GMX60 detector; averaged background region at 500 keV); smaller GMX detectors give lower values1
Background rate0.5 cps or lower with rectangular or cylindrical shields1

Mechanical

Maximum sample size3.5 in diameter × 3 in high (up to 750 mL)1

Ordering & accessories

Included softwareGammaVision; a computer is typically not included but can be provided on request1

General

ElectronicsDSPEC-502A digital dual MCA (setup under 30 minutes) and 556H power supply for the NaI annulus1
Lead shieldingCylindrical, 10 cm (4 in) reprocessed lead with inner liner (Tn/Cu); cavity 11 in diameter × 18 in high; optional cosmic veto with plastic scintillator1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ORTEC (AMETEK)Product page Specifications and Ordering Information – Model CSS-D-60 Checked 2026-10-16
GAMMA-X (GMX) HPGe-detektorer
ORTEC

GAMMA-X (GMX) HPGe-detektorer

HPGe gamma detector

Energy range
Approximately 5 keV–10 MeV
Relative efficiency
10–100%; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.85–1.40 keV for GMX10–GMX100; model-dependent; optimal shaping with DSPEC-50A
12 models
DSPEC 50/50A & 502/502A
ORTEC

DSPEC 50/50A & 502/502A

Digital gamma spectrometer / MCA

Spectrum channels
50/502: 512–16 k; 50A/502A: 256–64 k
Weight
DSPEC 50: 11 kg; DSPEC 502: 11.7 kg
4 models
GEM HPGe-detektorer
ORTEC

GEM HPGe-detektorer

HPGe detectors for gamma spectroscopy

Energy range
Approximately 40 keV and above
Relative efficiency
10–150% across the model series; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.80–1.30 keV for GEM10–GEM150; model-dependent
17 models
Safeguards planar HPGe-detektor
ORTEC

Safeguards planar HPGe-detektor

Planar HPGe gamma detector

Detector type
Planar HPGe
Energy resolution at 122 keV
Warranted FWHM for SGD-16550P4: 550 eV at 1 kcps, 6 μs; 615 eV at 50 kcps, 1 μs
7 models