Alfa- och betakällor

Calibration sources

Alpha and beta sources for calibration and operational checks of contamination monitors, probes and alpha spectrometers.

Radiation
Alpha or beta1
Source formats
Point sources and wide areas: discs, planchets, rectangles or squares1
Use
Calibration of alpha spectrometers and contamination monitors1
Standard radionuclides, EAS alpha
U-233, Pu-238, Pu-239, Am-241, Cm-2442

Specifications checked against the manufacturer’s documents on 2026-10-16

Manufacturer’s product page (opens in a new tab)

Overview

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

RadiationAlpha or beta1
Standard radionuclides, EAS alphaU-233, Pu-238, Pu-239, Am-241, Cm-2442
Alpha-flux measurement uncertainty, EAS catalog≤1.5% at k=22
Example radionuclides, EBS betaCl-36, Co-60, Sr-90/Y-90, Cs-137/Ba-137m, Pm-1473

Mechanical

Active diameter, standard EAS15 mm2
Active diameter, standard EBS3–30 mm3
Active diameters, standard ESA discs15, 36, 44 or 110 mm4
MountingA/B: aluminum ring; C/D: unmounted2

Environment & ratings

Source formatsPoint sources and wide areas: discs, planchets, rectangles or squares1

Ordering & accessories

Geometry optionsReplace [Type] with A, B, C or D when ordering2

General

UseCalibration of alpha spectrometers and contamination monitors1
Equivalent activity, EAS catalog0.3, 0.8 or 3 kBq, depending on nuclide2
Equivalent activity, EBS catalog0.08 or 3 kBq3
Equivalent activity, standard ESA discsAlpha: 0.4 kBq; beta: 4 kBq4
Measurement uncertainty≤1.5 %; k=22
Manufacturing tolerance±30 %2
Substrate and depositionStainless steel disk with electrodeposited radionuclides2
Listed ISO 2919 classC111112

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Models

10 models in the series. Filter or scroll the table to compare.

10 / 10
ModelRadionuclide2Alpha emission into 2π sr2Equivalent activity2Export control2
9ML04 EAS [Type] 25²³⁹Pu / ²⁴¹Am / ²⁴⁴Cm400 α/s0.8 kBqSubject to dual-use export control (EC Regulation 428/2009); an end-user certificate is requested
AM241 EAS [Type] 20²⁴¹Am150 α/s0.3 kBq–
AM241 EAS [Type] 30²⁴¹Am1500 α/s3 kBq–
CM244 EAS [Type] 20²⁴⁴Cm150 α/s0.3 kBq–
CM244 EAS [Type] 30²⁴⁴Cm1500 α/s3 kBq–
PU238 EAS [Type] 20²³⁸Pu150 α/s0.3 kBq–
PU238 EAS [Type] 30²³⁸Pu1500 α/s3 kBq–
PU239 EAS [Type] 20²³⁹Pu150 α/s0.3 kBqSubject to dual-use export control (EC Regulation 428/2009); an end-user certificate is requested
PU239 EAS [Type] 30²³⁹Pu1500 α/s3 kBqSubject to dual-use export control (EC Regulation 428/2009); an end-user certificate is requested
U233 EAS [Type] 20²³³U150 α/s0.3 kBqSubject to dual-use export control (EC Regulation 428/2009); an end-user certificate is requested

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: LEA / OranoProduct page product page Checked 2026-10-16
  2. 2
    Publisher: LEA / OranoProduct page product page; reference table (Under COFRAC accreditation); Manufacturing tolerances; reference table, note (1) Checked 2026-10-16
  3. 3
    Publisher: LEA / OranoProduct page product page Checked 2026-10-16
  4. 4
    Publisher: LEA / OranoProduct page product page Checked 2026-10-16
Medicinska kalibreringskällor
Orano LEA

Medicinska kalibreringskällor

Medical equipment calibration sources

Source form
Sealed sources
Use
Stability, efficiency and homogeneity checks and calibration
Equipment types
SPECT/PET, dose calibrators, well detectors and radiation-protection instruments
11 referenced values
Gasstandarder
Orano LEA

Gasstandarder

Gas calibration standards

Standard radionuclide
Kr-85
Radionuclides on request
For example Xe-133
Packaging
Glass ampoule or metal cylinder
10 referenced values
Flytande radioaktiva standarder
Orano LEA

Flytande radioaktiva standarder

Liquid calibration standards

Source form
Activity-characterized radioactive solution
Use
Detector calibration, quality control and periodic performance verification
Measurement methods
Gamma spectrometry or liquid scintillation counting
10 referenced values
LEA gamma- och röntgenkällor
Orano LEA

LEA gamma- och röntgenkällor

Calibration sources

Radiation
Gamma and X-rays
Source formats
Point sources; vegetable, resin, charcoal-filter and paper matrices
Use
Calibration and verification of spectrometers and radiation-protection instruments
12 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.