SI-6200 battericykler / analysator
Battery cycler / analyzer
- Measurement channels per module
- 10
- Applied voltage per channel
- −3 V to +10 V
- Maximum output current
- ±200 mA per channel

Bild: AMETEK SI
Battery cycler / analyzer
System for testing high-power batteries, fuel cells and electrolyzers that combines cycling with impedance measurements. Each module has up to five independent channels with built-in EIS on every channel.
Download product sheet (PDF)All values with references – for tender documents
Specifications checked against the manufacturer’s documents on 2026-10-16
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.
| Voltage measurement accuracy | ±0.01% FSR ±0.3 mV2 |
|---|
| Applied voltage per channel | +300 mV to +10 V2 |
|---|---|
| EIS frequency range | 10 mHz–10 kHz2 |
| Current measurement ranges | 300 A, 20 A, 2 A2 |
| Measurement channels per module | 5 in a fully populated module1 |
|---|---|
| Maximum output current | ±200 A continuous; 300 A for a 60 s pulse2 |
| Current with parallel channels | ±1,000 A1 |
| Voltage and current converters | 24-bit ADCs1 |
| Channels per cabinet | 42U: 40 channels; 24U: 20 channels (fully populated)1 |
| Software | Aspire Energy1 |
|---|
| Regenerative power supply | Yes1 |
|---|
| EIS capability | Built in on every channel, not multiplexed1 |
|---|---|
| Maximum data acquisition rate | 1,000 S/s on all channels1 |
The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.
6 models in the series. Filter or scroll the table to compare.
| Model | Installed channels2 | Cell connections2 | Applied voltage per channel2 | Current per channel2 | EIS frequency range2 | EIS | Converters1 | Maximum acquisition rate1 | Channel upgrades2 | Format3 | Software3 | Data storage3 | Placement3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SI-9300R | 5 | 4-terminal | +300 mV–+10 V | ±200 A continuous; 300 A pulse for 60 s | 10 mHz–10 kHz | Built in on every channel1 | 24-bit ADC | 1000 S/s, all channels | SI-9300R-DCDC_MODULE_UPGRADE, maximum 5 channels per module | – | – | – | – |
| SI-9300R-1CH | 1 | 4-terminal | +300 mV–+10 V | ±200 A continuous; 300 A pulse for 60 s | 10 mHz–10 kHz | Built in on every channel1 | 24-bit ADC | 1000 S/s, all channels | SI-9300R-DCDC_MODULE_UPGRADE, maximum 5 channels per module | – | – | – | – |
| SI-9300R-2CH | 2 | 4-terminal | +300 mV–+10 V | ±200 A continuous; 300 A pulse for 60 s | 10 mHz–10 kHz | Built in on every channel1 | 24-bit ADC | 1000 S/s, all channels | SI-9300R-DCDC_MODULE_UPGRADE, maximum 5 channels per module | – | – | – | – |
| SI-9300R-3CH | 3 | 4-terminal | +300 mV–+10 V | ±200 A continuous; 300 A pulse for 60 s | 10 mHz–10 kHz | Built in on every channel1 | 24-bit ADC | 1000 S/s, all channels | SI-9300R-DCDC_MODULE_UPGRADE, maximum 5 channels per module | – | – | – | – |
| SI-9300R-4CH | 4 | 4-terminal | +300 mV–+10 V | ±200 A continuous; 300 A pulse for 60 s | 10 mHz–10 kHz | Built in on every channel1 | 24-bit ADC | 1000 S/s, all channels | SI-9300R-DCDC_MODULE_UPGRADE, maximum 5 channels per module | – | – | – | – |
| SI-9300R-SA | – | – | – | – | – | Built in per channel3 | – | – | – | Battery test without centralized cabinet | Aspire Energy | Direct to disk; local NAS or Ethernet network | Near climate chamber or test fixture |
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Battery cycler / analyzer

Multichannel system for battery and energy storage testing