A Series (A400) RIID

Handheld RIID

A portable radioisotope identifier with directionality and high energy resolution without cryogenic cooling.

Detector type
A400: CZT (CdZnTe)1
Spectroscopy energy range
A400: 50–3000 keV1
Weight
A400: 1.2 kg1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-16

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Search for, identify and localize gamma sources.
  • CZT technology without liquid nitrogen.
  • Handheld instrument for field use.

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeA400: CZT (CdZnTe)1
Detector volumeA400: >19 cm³1
Neutron detectionOption A401: 16 cm² micro-structured neutron detector (MSND); 4.8 cps/nv from ANSI-moderated ²⁵²Cf (bare detector)1

Performance

Energy resolution at 662 keVA400: ≤1.1% FWHM (coincident interactions combined), ≤0.9% FWHM (separated), at 25 °C; high-resolution option A400+: ≤0.8% and ≤0.65%1

Measuring range

Spectroscopy energy rangeA400: 50–3000 keV1
Directionality energy rangeA400: 250–3000 keV1
Localization range250–3000 keV2
SensitivityA400: detects 10 µCi ¹³⁷Cs at 1 m (~3 µR/h) in <22 s in natural background; localises the source in <120 s to ±15°1
Dose-rate accuracyA400: ±20%, 50–1500 keV, forward direction, ≤0.2 rem/h (2 mSv/h); optional calibration improves accuracy to ±10%1
Count-rate limitA400: 1 rem/h (10 mSv/h) bare-¹³⁷Cs equivalent for spectroscopy1

Software & data

Nuclide libraryA400: selectable from the manufacturer-provisioned master library1

Connectivity & interface

User interfaceA400: embedded 3.5-inch screen with buttons; browser view1
CommunicationA400: Wi-Fi, Bluetooth, USB-C; RJ45 Ethernet through adapter1
Data storageA400: 32 GB internal, >1 million measurements; ANSI N42.42 XML1

Power & battery

Battery lifeA400: >8 hours1
Power supplyA400: 100–240 V, 47–63 Hz1

Mechanical

DimensionsA400: 30.5 × 7.6 × 9.5 cm (nominal)1
WeightA400: 1.2 kg1

Environment & ratings

Operating temperatureA400: −20 to +50 °C1
IP ratingA400: IP651
HumidityA400: up to 93% at 35 °C1
CertificationsA400: tested to pass ANSI N42.34 requirements; third-party DNDO TCS test report available on request1

General

Startup time<1.5 minutes2

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Models

6 models in the series. Filter or scroll the table to compare.

6 / 6
ModelEnergy resolution at 662 keV2CZT volume2Weight (manufacturer unit)2
A100<1.1 % FWHM>4.5 cm³2.5 lb
A100+<0.8 % FWHM>4.5 cm³2.5 lb
A200<1.1 % FWHM>9 cm³2.6 lb
A200+<0.8 % FWHM>9 cm³2.6 lb
A400<1.1 % FWHM>19 cm³2.6 lb
A400+<0.8 % FWHM>19 cm³2.6 lb

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: H3DDatasheet p. 2 'Gamma-Ray Detector'; p. 2 'Energy Range'; p. 2 'Nominal Dimensions'; p. 2 'Weight' … Checked 2026-10-16
  2. 2
    Publisher: H3DProduct page a400.php model table, column 'A100' (columns A100, A100+, A200, A200+, A400, A400+), row 'Imaging Range (keV)'; a400.php model table, column 'A100' (columns A100, A100+, A200, A200+, A400, A400+), row 'Startup Time (minutes)'; a400.php model table, column 'A100' (columns A100, A100+, A200, A200+, A400, A400+), row 'Resolution (% FWHM @ 662keV)'; a400.php model table, column 'A100' (columns A100, A100+, A200, A200+, A400, A400+), row 'CZT Volume (cm3)' … Checked 2026-10-16
H Series
H3D

H Series

Gamma imaging

Detector type
CZT (CdZnTe)
Spectroscopy energy range
50–3000 keV (H100/H400/H420/H1600)
IP rating
H100/H400/H420/H1600: IP67 (excluding external media)
9 models
GammAware 3D Radiation Imaging
H3D

GammAware 3D Radiation Imaging

3D radiation mapping

Mapping method
SLAM, simultaneous localization and mapping
Compatibility
H Series (e.g. H100/H400/H420) and M Series (e.g. M100/M400)
Visualization
Radiation hotspots overlaid on the scanned area’s 3D model
16 referenced values
T Series (T410)
H3D

T Series (T410)

Rugged integrable gamma imager

Detector type
T Series: CZT (CdZnTe)
Spectroscopy energy range
All tabulated T400S/T410 variants: 50–3000 keV
Weight
T410/T400S (including +): 8.7 lb; T410P/T410SP (including +): 10.9 lb
13 referenced values
P Series (P100)
H3D

P Series (P100)

Collimated gamma imager

Detector type
P100/P100S: CZT (CdZnTe)
Spectroscopy energy range
P100/P100S: 50–3000 keV
Weight
P100/P100S: 25 lb (approximately 11.3 kg)
13 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.