ModuLab XM MTS materialtestsystem
Materials test system
- Impedance range
- 10 µΩ–100 TΩ depending on module configuration
- EIS frequency range
- 10 µHz–1 MHz with XM MFRA 1MHz
- Maximum output current
- XM MAT: ±100 mA; XM MBST 2A: ±2 A (option)

Bild: AMETEK SI
Configurable electrochemical system
Configurable system for electrochemical, materials and photoelectrochemical measurements.
Download product sheet (PDF)All values with references – for tender documents
Specifications checked against the manufacturer’s documents on 2026-10-16
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.
| Polarization voltage | ±8 V standard; ±30 V with XM HV30; ±100 V with XM HV1001 |
|---|---|
| Minimum current range, standard | ±30 nA1 |
| EIS frequency range | XM FRA 1MHz: 10 µHz–1 MHz; XM FRA 300kHz: 10 µHz–300 kHz (options)1 |
| Maximum output current | ±300 mA base; XM BOOSTER 2A for 2 A; external boosters up to 100 A1 |
|---|---|
| Auxiliary inputs | XM PSTAT AUX: 4 differential voltage channels (factory-fitted option)1 |
| EIS analysis modes | Swept sine, multisine/FFT, harmonic analysis, intermodulation (FRA option)1 |
|---|---|
| Software | XM-Studio included1 |
| Compliance voltage | ±8 V standard; ±30 V / ±100 V with HV options1 |
|---|
| Chassis slots | 4 or 81 |
|---|---|
| Maximum data acquisition rate | 1 MS/s with XM PSTAT 1MS/s1 |
| Host system | ModuLab XM ECS; at least 1 PSTAT per chassis1 |
The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.
8 models in the series. Filter or scroll the table to compare.
| Model | Module function1 | Chassis slots1 | Installation1 | EIS requirement1 |
|---|---|---|---|---|
| XM BOOSTER 2A | 2 A booster; 8 V with PSTAT, up to 20 V with HV option | 2 | Plug-and-play, user-installable | FRA required for EIS |
| XM FEMTO AMMETER | Low-current option | 1 | Plug-and-play, user-installable | FRA required for EIS |
| XM FRA 1MHz | 10 µHz–1 MHz | 1 | Plug-and-play, user-installable | FRA module for EIS with PSTAT |
| XM FRA 300kHz | 10 µHz–300 kHz | 1 | Plug-and-play, user-installable | FRA module for EIS with PSTAT |
| XM HV30 | 30 V polarization and compliance voltage | 1 | Plug-and-play, user-installable | FRA required for EIS |
| XM HV100 | 100 V polarization and compliance voltage | 1 | Plug-and-play, user-installable | FRA required for EIS |
| XM PSTAT 1MS/s | Potentiostat/galvanostat; 1 MS/s | 1 | Plug-and-play, user-installable | FRA required for EIS |
| XM PSTAT AUX | 4 differential auxiliary voltage channels | 0 | Factory fitted to XM PSTAT | FRA required for EIS |
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Materials test system

Multichannel electrochemical system

Modular multichannel system

System chassis
We help you choose the right configuration, detector and accessories for your measurement task.