Products

Product catalogue

Search and filter detectors, measurement instruments, electronics and software. Every technical value is taken from the manufacturers’ own documents and referenced to its source.

Not sure what you need? Try the instrument finder
454 products

Products

NewFlint USB
BrightSpec

Flint USB

Integrated gamma probe: SiPM scintillation detector and digital MCA in one housing

Detector type
Scintillator with SiPM; standard round NaI(Tl), 2 × 2 or 3 × 3 in; can be ordered with CsI(Tl), CeBr₃, LaBr₃(Ce), LBC or SrI₂
Spectrum channels
256, 512, 1,024, 2,048 or 4,096, 32-bit depth per channel
13 referenced values
NewLabVision 4 ( LVis )
ORTEC

LabVision 4 ( LVis )

Software · analysis

Primary function
Nuclear spectrometry counting-laboratory management
Analysis engine
GammaVision and the tRAYcy Monte Carlo algorithm
Measurement workflow
Single-detector and automated multi-detector workflows
8 referenced values
Möbius Recycler
ORTEC

Möbius Recycler

HPGe detector cooling

Weight
28.58 kg empty; 51.26 kg full, excluding cryostat and detector
LN₂ hold time during power loss
Full dewar, typical detector: Streamline about 7–10 days; PopTop about 4–7 days
4 models
GEM HPGe-detektorer
ORTEC

GEM HPGe-detektorer

HPGe detectors for gamma spectroscopy

Energy range
Approximately 40 keV and above
Relative efficiency
10–150% across the model series; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.80–1.30 keV for GEM10–GEM150; model-dependent
17 models
ModuLab XM MTS materialtestsystem
AMETEK SI

ModuLab XM MTS materialtestsystem

Materials test system

Impedance range
10 µΩ–100 TΩ depending on module configuration
EIS frequency range
10 µHz–1 MHz with XM MFRA 1MHz
Maximum output current
XM MAT: ±100 mA; XM MBST 2A: ±2 A (option)
6 models
ModuLab XM ECS
AMETEK SI

ModuLab XM ECS

Configurable electrochemical system

Compliance voltage
±8 V standard; ±30 V / ±100 V with HV options
8 models
SI-9300R
AMETEK SI

SI-9300R

Battery cycler / analyzer

Measurement channels per module
5 in a fully populated module
Applied voltage per channel
+300 mV to +10 V
Maximum output current
±200 A continuous; 300 A for a 60 s pulse
6 models
PARSTAT MC
AMETEK SI

PARSTAT MC

Modular multichannel system

Measurement channels
Up to 20 with PMC-200; up to 10 with PMC-1000 or PMC-2000A
Compliance voltage
PMC-200: ±10 V; PMC-1000: ±12 V; PMC-2000A: ±30 V
3 models
Ludlum Model 3003
Ludlum

Ludlum Model 3003

SCA and detector readout

Weight excluding detectors and clips
0.9 kg
Enclosure rating and conditions
IP53
5 models
Alfa- och betakällor
Orano LEA

Alfa- och betakällor

Calibration sources

Radiation
Alpha or beta
Source formats
Point sources and wide areas: discs, planchets, rectangles or squares
Use
Calibration of alpha spectrometers and contamination monitors
10 models
RCAP-2 rekylskyddspaket
ORTEC

RCAP-2 rekylskyddspaket

Alpha spectrometry accessory

Models
RCAP-2-120V; RCAP-2-240V
Supply voltage
RCAP-2-120V: 120 V; RCAP-2-240V: 240 V
Sample-holder bias
−12 V
2 models
Alpha Suite alfaspektrometrar
ORTEC

Alpha Suite alfaspektrometrar

Integrated alpha spectrometry

Energy resolution
≤20 keV FWHM with BU-017-450-100 ULTRA detector and ²⁴¹Am point source; detector-to-source spacing equal to detector diameter
Spectrum channels
Software-selectable conversion gain: 256, 512, 1024, 2048 or 4096 channels
19 models
digiDART
ORTEC

digiDART

Portable digital MCA

Compatible detectors
SMART-1 HPGe detectors; other detectors via a Detector Interface Module (DIM)
Spectrum channels
512–16 k
1 model
928 EASY-NIM
ORTEC

928 EASY-NIM

NIM mca, counter and timer

Spectrum channels
512–16,384, software selectable
Weight
0.9 kg net
3 models
DSPEC 50/50A & 502/502A
ORTEC

DSPEC 50/50A & 502/502A

Digital gamma spectrometer / MCA

Spectrum channels
50/502: 512–16 k; 50A/502A: 256–64 k
Weight
DSPEC 50: 11 kg; DSPEC 502: 11.7 kg
4 models
Shallow Hole Probe
ORTEC

Shallow Hole Probe

HPGe gamma detector

Detector type
Configured with GEM, GMX, GLP, PROFILE or Safeguards HPGe
Weight
Approximately 12 lb
LN₂ holding time
Approximately 16 hours with 70 mm endcap
1 model
Dewars and Cryostats
ORTEC

Dewars and Cryostats

HPGe detector cooling

Cooling technology
Liquid nitrogen (LN₂)
Cryostat configurations
Vertical and horizontal dipstick, portable (all-position or multi-orientation Gamma Gage), down-looking, side-looking and J-type, depending on detector configuration
Dewar capacity
Gamma Gage: 1.2/3/5 L; MOD multi-orientation: 3/7 L; side-looking and down-looking: 7.5/13/30 L; dipstick cryostats: 30 L (DWR-30); shallow-hole probe: 0.7 L
43 models
Safeguards planar HPGe-detektor
ORTEC

Safeguards planar HPGe-detektor

Planar HPGe gamma detector

Detector type
Planar HPGe
Energy resolution at 122 keV
Warranted FWHM for SGD-16550P4: 550 eV at 1 kcps, 6 μs; 615 eV at 50 kcps, 1 μs
7 models
Safeguards koaxial HPGe-detektor
ORTEC

Safeguards koaxial HPGe-detektor

HPGe gamma detector

Detector type
HPGe, coaxial or semi-planar by SGD-GEM model
Energy resolution at 122 keV
FWHM maximum limits 0.61–0.80 keV at 1 kcps and optimal shaping; model-dependent
4 models
GLP plana HPGe-detektorer
ORTEC

GLP plana HPGe-detektorer

HPGe gamma detector

Energy range
Approximately 5–300 keV
Active area
Nominally 80–1,000 mm², model-dependent
Energy resolution at 122 keV
FWHM maximum limits 0.51–0.63 keV for the tabulated models
8 models
Showing 24 of 454