Netherlands

Scionix

Dutch specialist in scintillation detectors since 1992 – standard and tailor-made detectors in all common scintillation materials, from plastic and liquid scintillators to NaI(Tl), CsI(Tl), BGO and CeBr₃.

Website

HPGe & gamma spectroscopy

20 products

76B76/3M
Scionix

76B76/3M

76 x 76 mm (3" x 3") NaI(Tl) scintillation detector

Scintillator
NaI(Tl)
Crystal dimensions
76 x 76 mm (3" x 3")
Light sensor
Photomultiplier tube, 3 in. (76 mm), bialkali photocathode
11 referenced values
51B51/2M
Scionix

51B51/2M

51 x 51 mm (2" x 2") NaI(Tl) scintillation detector

Scintillator
NaI(Tl)
Crystal dimensions
Ø 51 x 51 mm (diameter x height)
Light sensor
Photomultiplier tube, 2 in. (51 mm), bialkali photocathode
10 referenced values
NaI(Tl) Well Detectors
Scionix

NaI(Tl) Well Detectors

NaI(Tl) detectors with axial well (BP style)

Scintillator
NaI(Tl)
Crystal dimensions
51 x 76 mm or 76 x 76 mm, with axial well
5 referenced values
102 x 102 mm NaI(Tl) Detector
Scionix

102 x 102 mm NaI(Tl) Detector

102 x 102 mm NaI(Tl) detector with built-in voltage divider

Scintillator
NaI(Tl)
Crystal dimensions
102 x 102 mm
Electronics
Built-in voltage divider
7 referenced values
127A127/5M
Scionix

127A127/5M

127 x 127 mm NaI(Tl) detector with demountable photomultiplier tube

Crystal dimensions
Ø 127 x 127 mm (diameter x height)
Light sensor
Demountable photomultiplier tube, 127 mm (5 in.)
9 referenced values
C-Style Crystal Assemblies
Scionix

C-Style Crystal Assemblies

Encapsulated scintillation crystals without photomultiplier tube

Energy range
Gamma rays and X-rays 30 keV–2 MeV; for higher energies BGO without optical window
Entrance window
Thin window (CA/CD): 25 µm aluminium from 10 keV or 0.25–0.3 mm beryllium from 3 keV
7 referenced values
FIDLER Probes 127BD1.6 / 127BA1.6
Scionix

FIDLER Probes 127BD1.6 / 127BA1.6

FIDLER probes for low-energy X-rays and gamma rays

Scintillator
NaI(Tl), 127 x 1.6 mm, specially treated for X-ray response
Entrance window
0.25 mm beryllium (above 2 keV, BD model) or 0.025 mm aluminium (above 10 keV, BA model); extra 20 µm Kapton protection
Energy resolution
< 25% for I-129 (30 keV); < 17% for Am-241 (60 keV)
11 referenced values
CeBr3 Scintillation Detectors
Scionix

CeBr3 Scintillation Detectors

High-resolution, low-background CeBr₃ scintillation detectors

Energy resolution at 662 keV
4% FWHM (typical)
Decay time
18–25 ns, size dependent (typical)
Maximum crystal size
Ø 127 mm, 152 mm high
11 referenced values
ILLUSTRATION
Scionix

LBC Scintillation Detectors

High-resolution LBC (lanthanum bromochloride) scintillation detectors

Energy resolution at 662 keV
3% FWHM (typical)
Photoelectron yield (NaI(Tl) = 100)
140
9 referenced values
SrI2(Eu) Scintillation Detectors
Scionix

SrI2(Eu) Scintillation Detectors

High-resolution SrI₂(Eu) scintillation detectors

Energy resolution at 662 keV
Approx. 3.5% FWHM
Light yield
80 photons/keV
Maximum crystal size
38 x 38 mm
11 referenced values
ILLUSTRATION
Scionix

CLLBC Scintillation Detectors

Dual-mode CLLBC scintillators for gamma rays and neutrons

Energy resolution at 662 keV
< 3.5% FWHM
Thermal neutron peak
Sharp peak at 3.1–3.2 MeV
⁶Li enrichment
95%
13 referenced values
ILLUSTRATION
Scionix

CLYC Scintillation Detectors

CLYC:Ce scintillators for neutrons and gamma rays

⁶Li enrichment
96%
Energy resolution at 662 keV
4.5–5.5% FWHM depending on geometry
Thermal neutron peak
3.1–3.3 MeV
13 referenced values
EJ-309 Liquid Scintillation Detectors
Scionix

EJ-309 Liquid Scintillation Detectors

EJ-309 liquid scintillation detectors for fast neutrons and gamma rays

Pulse shape discrimination
Neutron/gamma separation by PSD, just slightly inferior to EJ-301
Active volume
Examples: 51 x 51 mm, 76 x 76 mm and 150 x 150 x 150 mm
Flash point
144 °C; not listed as dangerous goods
12 referenced values
SiPM Scintillation Detectors
Scionix

SiPM Scintillation Detectors

Scintillation detectors with silicon photomultipliers (SiPM)

Power supply
5 V, less than 5 mA
Temperature compensation
Built-in temperature-compensated bias generator and preamplifier
Energy resolution
Comparable to photomultiplier tube readout
10 referenced values
48B38/SIP-CS-E3-X
Scionix

48B38/SIP-CS-E3-X

CsI(Tl) SiPM detector with temperature-compensated bias and preamplifier

Scintillator
CsI(Tl), 48 x 38 mm
Power supply
5.2–16 V (25 mW)
Energy resolution at 662 keV
< 8% FWHM
13 referenced values
51BM0.25/SIP-EJ444-E3-X2
Scionix

51BM0.25/SIP-EJ444-E3-X2

Thin alpha/beta SiPM detector (ZnS(Ag) + plastic scintillator)

Scintillator
ZnS(Ag) + plastic scintillator, Ø 51 x 0.25 mm (EJ-444)
Power supply
+5–16 V (3 mA)
Compatible electronics
BrightSpec Topaz-SiPM (compatible connector)
13 referenced values
51BM0.25/SIP-EJ440-E3-X2
Scionix

51BM0.25/SIP-EJ440-E3-X2

Thin alpha SiPM detector (ZnS(Ag))

Scintillator
ZnS(Ag), Ø 51 x 0.25 mm (EJ-440)
Power supply
+5–16 V (3 mA)
10 referenced values
Compton Suppression Shields
Scionix

Compton Suppression Shields

BGO or NaI(Tl) anti-Compton shields for HPGe detectors

Scintillator
BGO for nuclear spectroscopy; low-background NaI(Tl) for low-level counting
7 referenced values
Pen-Type Detector 9.5B20
Scionix

Pen-Type Detector 9.5B20

Pen-type NaI(Tl) detector with electronics box (amplifier, SCA, high voltage)

Scintillator
NaI(Tl), 9.5 x 20 mm (other shapes on request)
Energy resolution
< 8% FWHM at 662 keV; < 17% FWHM at 122 keV
Power supply
+12 V, less than 300 mW
10 referenced values
VD14-E2
Scionix

VD14-E2

Plug-on voltage divider with preamplifier for 14-pin photomultiplier tubes

Output impedance
50 Ω
Rise time
< 50 ns
Cable
Drives cable lengths of 100 m or more
8 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.