EJ-309 Liquid Scintillation Detectors

EJ-309 liquid scintillation detectors for fast neutrons and gamma rays

Detectors with the EJ-309 liquid scintillator, which has a flash point of 144 °C and is not listed as dangerous goods. Neutrons and gamma rays are separated by pulse shape discrimination. The cell is hermetically sealed with an expansion reservoir and keeps full optical contact in every orientation. Also available boron-loaded as EJ-309:B5.

Pulse shape discrimination
Neutron/gamma separation by PSD, just slightly inferior to EJ-3011
Active volume
Examples: 51 x 51 mm, 76 x 76 mm and 150 x 150 x 150 mm2
Flash point
144 °C; not listed as dangerous goods1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-11-26

Manufacturer’s product page (opens in a new tab)

Already have the instrument? Request service or support →

Overview

Key features

  • Neutron/gamma separation by PSD
  • Flash point 144 °C, not dangerous goods
  • From 51 x 51 mm to 150 x 150 x 150 mm
  • Boron-loaded EJ-309:B5 variant

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

ScintillatorEJ-309 liquid scintillator; optionally boron-loaded EJ-309:B5 (up to 5% natural boron)1
Active volumeExamples: 51 x 51 mm, 76 x 76 mm and 150 x 150 x 150 mm2
Light sensorFast photomultiplier tubes (2–3 ns rise time) with transistorised voltage dividers at negative high voltage2

Electronics & signal

Pulse shape discriminationNeutron/gamma separation by PSD, just slightly inferior to EJ-3011
Light output relative to anthracene75% (EJ-309:B5: 52%)1

General

FormatHermetically sealed cell with expansion reservoir; 100% optical contact between liquid and window in every orientation2
Light yield11,500 photons/MeV (electrons); EJ-309:B5 approx. 8,0001
Emission maximum424 nm1
Density0.964 g/cm³ at 15 °C (EJ-309:B5: 0.963 g/cm³)1
Flash point144 °C; not listed as dangerous goods1
Decay timeApprox. 3.5 ns (short component)1
Refractive index1.571

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ScionixDatasheet p. 1; p. 1, table Checked 2026-11-26
  2. 2
    Publisher: ScionixProduct page Liquid Scintillation detectors Checked 2026-11-26
ILLUSTRATION
Scionix

CLLBC Scintillation Detectors

Dual-mode CLLBC scintillators for gamma rays and neutrons

Energy resolution at 662 keV
< 3.5% FWHM
Thermal neutron peak
Sharp peak at 3.1–3.2 MeV
⁶Li enrichment
95%
13 referenced values
ILLUSTRATION
Scionix

CLYC Scintillation Detectors

CLYC:Ce scintillators for neutrons and gamma rays

⁶Li enrichment
96%
Energy resolution at 662 keV
4.5–5.5% FWHM depending on geometry
Thermal neutron peak
3.1–3.3 MeV
13 referenced values
76B76/3M
Scionix

76B76/3M

76 x 76 mm (3" x 3") NaI(Tl) scintillation detector

Scintillator
NaI(Tl)
Crystal dimensions
76 x 76 mm (3" x 3")
Light sensor
Photomultiplier tube, 3 in. (76 mm), bialkali photocathode
11 referenced values
51B51/2M
Scionix

51B51/2M

51 x 51 mm (2" x 2") NaI(Tl) scintillation detector

Scintillator
NaI(Tl)
Crystal dimensions
Ø 51 x 51 mm (diameter x height)
Light sensor
Photomultiplier tube, 2 in. (51 mm), bialkali photocathode
10 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.