51BM0.25/SIP-EJ440-E3-X2

Thin alpha SiPM detector (ZnS(Ag))

Thin alpha detector with a ZnS(Ag) scintillator (EJ-440), Ø 51 x 0.25 mm, read out by a SiPM array with a built-in temperature-compensated bias generator and preamplifier. It runs on +5–16 V and connects through a LEMO connector or flying leads.

Scintillator
ZnS(Ag), Ø 51 x 0.25 mm (EJ-440)1
Power supply
+5–16 V (3 mA)1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-11-26

Manufacturer’s product page (opens in a new tab)

Already have the instrument? Request service or support →

Overview

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

ScintillatorZnS(Ag), Ø 51 x 0.25 mm (EJ-440)1
Light sensorSiPM array J-60035-4P1

Electronics & signal

GainApprox. 500 mV per 5.48 MeV (alpha)1

Connectivity & interface

Electrical connectionLEMO FFA0S302CLAC44 or flying leads; 100 cm shielded 4-core cable1

Power & battery

Power supply+5–16 V (3 mA)1

Mechanical

Detector housingBlack light-tight polyester1

Environment & ratings

Entrance windowLight-tight double aluminised Mylar, 0.9 mg/cm²1

General

Protection gridStainless steel grid with 72% transmission1
Rise time1 µs (alpha, 0–100%)1
Fall time3 µs (alpha)1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ScionixDatasheet p. 1 Checked 2026-11-26
51BM0.25/SIP-EJ444-E3-X2
Scionix

51BM0.25/SIP-EJ444-E3-X2

Thin alpha/beta SiPM detector (ZnS(Ag) + plastic scintillator)

Scintillator
ZnS(Ag) + plastic scintillator, Ø 51 x 0.25 mm (EJ-444)
Power supply
+5–16 V (3 mA)
Compatible electronics
BrightSpec Topaz-SiPM (compatible connector)
13 referenced values
SiPM Scintillation Detectors
Scionix

SiPM Scintillation Detectors

Scintillation detectors with silicon photomultipliers (SiPM)

Power supply
5 V, less than 5 mA
Temperature compensation
Built-in temperature-compensated bias generator and preamplifier
Energy resolution
Comparable to photomultiplier tube readout
10 referenced values
FIDLER Probes 127BD1.6 / 127BA1.6
Scionix

FIDLER Probes 127BD1.6 / 127BA1.6

FIDLER probes for low-energy X-rays and gamma rays

Scintillator
NaI(Tl), 127 x 1.6 mm, specially treated for X-ray response
Entrance window
0.25 mm beryllium (above 2 keV, BD model) or 0.025 mm aluminium (above 10 keV, BA model); extra 20 µm Kapton protection
Energy resolution
< 25% for I-129 (30 keV); < 17% for Am-241 (60 keV)
11 referenced values
Pen-Type Detector 9.5B20
Scionix

Pen-Type Detector 9.5B20

Pen-type NaI(Tl) detector with electronics box (amplifier, SCA, high voltage)

Scintillator
NaI(Tl), 9.5 x 20 mm (other shapes on request)
Energy resolution
< 8% FWHM at 662 keV; < 17% FWHM at 122 keV
Power supply
+12 V, less than 300 mW
10 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.