Integrated NaI(Tl) detectors with an axial well in the crystal, where the sample sits inside the detector. Scionix shows standard versions of 51 x 76 mm and 76 x 76 mm, with crystal and photomultiplier tube sealed in one housing.

Scintillator
NaI(Tl)1
Crystal dimensions
51 x 76 mm or 76 x 76 mm, with axial well1

Specifications checked against the manufacturer’s documents on 2026-11-26

Manufacturer’s product page (opens in a new tab)

Already have the instrument? Request service or support →

Overview

Key features

  • Axial well for the sample
  • Crystal and tube in one sealed housing
  • 51 x 76 mm or 76 x 76 mm

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

ScintillatorNaI(Tl)1
Crystal dimensions51 x 76 mm or 76 x 76 mm, with axial well1
FormatIntegrated B style with an axial well in the crystal (BP)1
HV polarityPositive high voltage (standard); -NEG in the type number means negative2
ElectronicsPlug-on or built-in voltage divider; optional preamplifier/line driver with a 50 Ω output for over 100 m of cable3

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ScionixProduct page B-style detectors with axial well; Assemblies with integrated photomultiplier tubes Checked 2026-11-26
  2. 2
    Publisher: ScionixProduct page Positive or Negative High Voltage? Checked 2026-11-26
  3. 3
    Publisher: ScionixManual p. 39 Checked 2026-11-26
C-Style Crystal Assemblies
Scionix

C-Style Crystal Assemblies

Encapsulated scintillation crystals without photomultiplier tube

Energy range
Gamma rays and X-rays 30 keV–2 MeV; for higher energies BGO without optical window
Entrance window
Thin window (CA/CD): 25 µm aluminium from 10 keV or 0.25–0.3 mm beryllium from 3 keV
7 referenced values
51B51/2M
Scionix

51B51/2M

51 x 51 mm (2" x 2") NaI(Tl) scintillation detector

Scintillator
NaI(Tl)
Crystal dimensions
Ø 51 x 51 mm (diameter x height)
Light sensor
Photomultiplier tube, 2 in. (51 mm), bialkali photocathode
10 referenced values
76B76/3M
Scionix

76B76/3M

76 x 76 mm (3" x 3") NaI(Tl) scintillation detector

Scintillator
NaI(Tl)
Crystal dimensions
76 x 76 mm (3" x 3")
Light sensor
Photomultiplier tube, 3 in. (76 mm), bialkali photocathode
11 referenced values
102 x 102 mm NaI(Tl) Detector
Scionix

102 x 102 mm NaI(Tl) Detector

102 x 102 mm NaI(Tl) detector with built-in voltage divider

Scintillator
NaI(Tl)
Crystal dimensions
102 x 102 mm
Electronics
Built-in voltage divider
7 referenced values