C-Style Crystal Assemblies

Encapsulated scintillation crystals without photomultiplier tube

Crystals in an aluminium, stainless steel or copper housing, sealed with a glass or quartz window for the customer’s own photomultiplier tube. Available with an axial well (CP) for well counters and with a thin aluminium or beryllium window (CA/CD) for low-energy X-rays.

Energy range
Gamma rays and X-rays 30 keV–2 MeV; for higher energies BGO without optical window1
Entrance window
Thin window (CA/CD): 25 µm aluminium from 10 keV or 0.25–0.3 mm beryllium from 3 keV1

Specifications checked against the manufacturer’s documents on 2026-11-26

Manufacturer’s product page (opens in a new tab)

Already have the instrument? Request service or support →

Overview

Key features

  • For the customer’s own photomultiplier tube
  • CP well style with standard dimensions
  • Thin window down to 3 keV (beryllium)
  • Rugged and low-background versions

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

FormatCrystal in an aluminium, stainless steel or copper housing; hygroscopic crystals are sealed with a glass or quartz window for optical coupling to the customer’s light sensor1
Detector housingAluminium 0.5 mm (standard) or stainless steel 0.8 mm (harsh environments)1
Energy rangeGamma rays and X-rays 30 keV–2 MeV; for higher energies BGO without optical window1
Well dimensions (CP)51 CP 51: Ø 25.4 x 39.3 mm or Ø 16.6 x 39.3 mm; 76 CP 76: Ø 25.4 x 52 mm; well wall 0.3 mm aluminium1
Entrance windowThin window (CA/CD): 25 µm aluminium from 10 keV or 0.25–0.3 mm beryllium from 3 keV1
UseThe CP style is used in well counters, e.g. in medical applications, and in wipe test detectors1
Detector optionLow-background materials (steel or copper), ruggedised version (CR), flanges or O-ring grooves1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ScionixProduct page C-styles and CP-styles; Application; Thin window crystal assemblies: CA-styles, CD-styles Checked 2026-11-26
NaI(Tl) Well Detectors
Scionix

NaI(Tl) Well Detectors

NaI(Tl) detectors with axial well (BP style)

Scintillator
NaI(Tl)
Crystal dimensions
51 x 76 mm or 76 x 76 mm, with axial well
5 referenced values
FIDLER Probes 127BD1.6 / 127BA1.6
Scionix

FIDLER Probes 127BD1.6 / 127BA1.6

FIDLER probes for low-energy X-rays and gamma rays

Scintillator
NaI(Tl), 127 x 1.6 mm, specially treated for X-ray response
Entrance window
0.25 mm beryllium (above 2 keV, BD model) or 0.025 mm aluminium (above 10 keV, BA model); extra 20 µm Kapton protection
Energy resolution
< 25% for I-129 (30 keV); < 17% for Am-241 (60 keV)
11 referenced values
76B76/3M
Scionix

76B76/3M

76 x 76 mm (3" x 3") NaI(Tl) scintillation detector

Scintillator
NaI(Tl)
Crystal dimensions
76 x 76 mm (3" x 3")
Light sensor
Photomultiplier tube, 3 in. (76 mm), bialkali photocathode
11 referenced values
51B51/2M
Scionix

51B51/2M

51 x 51 mm (2" x 2") NaI(Tl) scintillation detector

Scintillator
NaI(Tl)
Crystal dimensions
Ø 51 x 51 mm (diameter x height)
Light sensor
Photomultiplier tube, 2 in. (51 mm), bialkali photocathode
10 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.