FIDLER probes for low-energy X-rays and gamma rays
Probes with a thin 127 x 1.6 mm NaI(Tl) crystal coupled through a quartz light guide to a low-background photomultiplier tube. They are designed to detect small quantities of low-energy X-rays and gamma rays and have a 14-pin base that fits USB-based digital MCAs. The BD model has a beryllium window, the BA model an aluminium window.
Download product sheet (PDF)All values with references – for tender documents
Specifications checked against the manufacturer’s documents on 2026-11-26
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.
| Scintillator | NaI(Tl), 127 x 1.6 mm, specially treated for X-ray response1 |
|---|---|
| Light sensor | Low-background photomultiplier tube, 130 mm, EMI 9390, via a quartz light guide1 |
| Optical window | Low-background quartz, 51 mm thick1 |
| Energy resolution | < 25% for I-129 (30 keV); < 17% for Am-241 (60 keV)1 |
|---|
| Electrical connection | 14-pin base compatible with all available USB-based digital MCAs1 |
|---|
| Detector housing | Passivated aluminium; a black DELRIN cover (3 mm) protects the thin window1 |
|---|---|
| Dimensions | Maximum diameter at collar 142 mm; PMT base diameter 59 mm; length up to connector 240 mm1 |
| Entrance window | 0.25 mm beryllium (above 2 keV, BD model) or 0.025 mm aluminium (above 10 keV, BA model); extra 20 µm Kapton protection1 |
|---|---|
| Operating temperature | −10 to +60 °C1 |
| Maximum temperature gradient | 20 °C per hour1 |
| Magnetic shielding | Solid µ-metal shield around the photomultiplier tube1 |
|---|
The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

MCA and PMT base for nai(tl)

Compact digital MCA built into the tube socket, for scintillation detectors

Encapsulated scintillation crystals without photomultiplier tube

Thin alpha/beta SiPM detector (ZnS(Ag) + plastic scintillator)
We help you choose the right configuration, detector and accessories for your measurement task.