51BM0.25/SIP-EJ444-E3-X2

Thin alpha/beta SiPM detector (ZnS(Ag) + plastic scintillator)

Thin detector for alpha and beta radiation with a ZnS(Ag) and plastic scintillator (EJ-444), Ø 51 x 0.25 mm, read out by a SiPM array. The bias generator and preamplifier are built in and temperature-compensated. Alphas and betas are separated by pulse shape discrimination, and the connector fits the BrightSpec Topaz-SiPM.

Scintillator
ZnS(Ag) + plastic scintillator, Ø 51 x 0.25 mm (EJ-444)1
Power supply
+5–16 V (3 mA)1
Compatible electronics
BrightSpec Topaz-SiPM (compatible connector)1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-11-26

Manufacturer’s product page (opens in a new tab)

Already have the instrument? Request service or support →

Overview

Key features

  • Alpha and beta in one detector
  • Separation by pulse shape discrimination
  • Fits the BrightSpec Topaz-SiPM
  • +5–16 V, 3 mA

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

ScintillatorZnS(Ag) + plastic scintillator, Ø 51 x 0.25 mm (EJ-444)1
Light sensorSiPM array J-60035-4P1

Performance

Noise level< 50 keV (beta) at 22 °C1

Electronics & signal

GainApprox. 75 mV/MeV (beta); approx. 500 mV per 5.48 MeV (alpha)1
Pulse shape discriminationAlphas and betas are separated by pulse shape discrimination (2D PSD)1

Connectivity & interface

Electrical connectionLEMO FFA0S302CLAC44; 50 cm shielded 4-core cable1

Power & battery

Power supply+5–16 V (3 mA)1

Mechanical

Detector housingBlack light-tight polyester1

Environment & ratings

Entrance windowLight-tight double aluminised Mylar, 0.9 mg/cm²1

General

Protection gridStainless steel grid with 72% transmission1
Compatible electronicsBrightSpec Topaz-SiPM (compatible connector)1
Rise time150 ns (beta), 1 µs (alpha), 0–100%1
Fall time1.2 µs (beta), 3 µs (alpha)1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ScionixDatasheet p. 1; p. 2 Checked 2026-11-26
Topaz-SiPM
BrightSpec

Topaz-SiPM

Miniature MCA for scintillators with silicon photomultipliers (SiPM)

Spectrum channels
Up to 4,096
Weight
Less than 70 g (including box)
11 referenced values
51BM0.25/SIP-EJ440-E3-X2
Scionix

51BM0.25/SIP-EJ440-E3-X2

Thin alpha SiPM detector (ZnS(Ag))

Scintillator
ZnS(Ag), Ø 51 x 0.25 mm (EJ-440)
Power supply
+5–16 V (3 mA)
10 referenced values
SiPM Scintillation Detectors
Scionix

SiPM Scintillation Detectors

Scintillation detectors with silicon photomultipliers (SiPM)

Power supply
5 V, less than 5 mA
Temperature compensation
Built-in temperature-compensated bias generator and preamplifier
Energy resolution
Comparable to photomultiplier tube readout
10 referenced values
FIDLER Probes 127BD1.6 / 127BA1.6
Scionix

FIDLER Probes 127BD1.6 / 127BA1.6

FIDLER probes for low-energy X-rays and gamma rays

Scintillator
NaI(Tl), 127 x 1.6 mm, specially treated for X-ray response
Entrance window
0.25 mm beryllium (above 2 keV, BD model) or 0.025 mm aluminium (above 10 keV, BA model); extra 20 µm Kapton protection
Energy resolution
< 25% for I-129 (30 keV); < 17% for Am-241 (60 keV)
11 referenced values