76B76/3M

76 x 76 mm (3" x 3") NaI(Tl) scintillation detector

The detector Scionix calls the standard for general gamma spectroscopy: a 76 x 76 mm NaI(Tl) crystal coupled directly to a 3-inch photomultiplier tube, hermetically sealed in a light-tight housing with a µ-metal shield. It ends in a 14-pin socket and is available in a low-background version.

Scintillator
NaI(Tl)1
Crystal dimensions
76 x 76 mm (3" x 3")1
Light sensor
Photomultiplier tube, 3 in. (76 mm), bialkali photocathode2

Specifications checked against the manufacturer’s documents on 2026-11-26

Manufacturer’s product page (opens in a new tab)

Already have the instrument? Request service or support →

Overview

Key features

  • The standard detector for gamma spectroscopy according to Scionix
  • Crystal and tube in one sealed housing
  • 14-pin socket for a voltage divider
  • Available in a low-background version

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

ScintillatorNaI(Tl)1
Light sensorPhotomultiplier tube, 3 in. (76 mm), bialkali photocathode2

Mechanical

Crystal dimensions76 x 76 mm (3" x 3")1
Detector housingSilver anodised aluminium (standard)3

Ordering & accessories

Detector optionLow-background (LB) version: low-background steel or electrolytic copper housing, selected components and quartz or undoped NaI light guides1

General

UseGeneral gamma spectroscopy – according to Scionix the standard detector, with excellent efficiency and energy resolution1
FormatIntegrated (B style): the crystal is coupled directly to the photomultiplier tube and both are hermetically sealed in a light-tight housing1
Magnetic shieldingExternal solid µ-metal shield (M in the type number)3
PMT base14-pin JEDEC B14-38 socket, standard for detectors supplied without voltage divider4
HV polarityPositive high voltage (standard); -NEG in the type number means negative4
ElectronicsPlug-on or built-in voltage divider; optional preamplifier/line driver with a 50 Ω output for over 100 m of cable2

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ScionixProduct page Assemblies with integrated photomultiplier tubes; Assemblies with integrated photomultiplier tubes: B-styles Checked 2026-11-26
  2. 2
    Publisher: ScionixManual pp. 37–53 and 74; p. 39 Checked 2026-11-26
  3. 3
    Publisher: ScionixProduct page 7. Electronics/ features of PMT; Standard “off the shelf” detectors Checked 2026-11-26
  4. 4
    Publisher: ScionixProduct page Plug-on or integrated?; Positive or Negative High Voltage? Checked 2026-11-26
51B51/2M
Scionix

51B51/2M

51 x 51 mm (2" x 2") NaI(Tl) scintillation detector

Scintillator
NaI(Tl)
Crystal dimensions
Ø 51 x 51 mm (diameter x height)
Light sensor
Photomultiplier tube, 2 in. (51 mm), bialkali photocathode
10 referenced values
VD14-E2
Scionix

VD14-E2

Plug-on voltage divider with preamplifier for 14-pin photomultiplier tubes

Output impedance
50 Ω
Rise time
< 50 ns
Cable
Drives cable lengths of 100 m or more
8 referenced values
102 x 102 mm NaI(Tl) Detector
Scionix

102 x 102 mm NaI(Tl) Detector

102 x 102 mm NaI(Tl) detector with built-in voltage divider

Scintillator
NaI(Tl)
Crystal dimensions
102 x 102 mm
Electronics
Built-in voltage divider
7 referenced values
NaI(Tl) Well Detectors
Scionix

NaI(Tl) Well Detectors

NaI(Tl) detectors with axial well (BP style)

Scintillator
NaI(Tl)
Crystal dimensions
51 x 76 mm or 76 x 76 mm, with axial well
5 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.