51B51/2M
51 x 51 mm (2" x 2") NaI(Tl) scintillation detector
- Scintillator
- NaI(Tl)
- Crystal dimensions
- Ø 51 x 51 mm (diameter x height)
- Light sensor
- Photomultiplier tube, 2 in. (51 mm), bialkali photocathode

Bild: Scionix
76 x 76 mm (3" x 3") NaI(Tl) scintillation detector
The detector Scionix calls the standard for general gamma spectroscopy: a 76 x 76 mm NaI(Tl) crystal coupled directly to a 3-inch photomultiplier tube, hermetically sealed in a light-tight housing with a µ-metal shield. It ends in a 14-pin socket and is available in a low-background version.
Download product sheet (PDF)All values with references – for tender documents
Specifications checked against the manufacturer’s documents on 2026-11-26
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.
| Crystal dimensions | 76 x 76 mm (3" x 3")1 |
|---|---|
| Detector housing | Silver anodised aluminium (standard)3 |
| Detector option | Low-background (LB) version: low-background steel or electrolytic copper housing, selected components and quartz or undoped NaI light guides1 |
|---|
| Use | General gamma spectroscopy – according to Scionix the standard detector, with excellent efficiency and energy resolution1 |
|---|---|
| Format | Integrated (B style): the crystal is coupled directly to the photomultiplier tube and both are hermetically sealed in a light-tight housing1 |
| Magnetic shielding | External solid µ-metal shield (M in the type number)3 |
| PMT base | 14-pin JEDEC B14-38 socket, standard for detectors supplied without voltage divider4 |
| HV polarity | Positive high voltage (standard); -NEG in the type number means negative4 |
| Electronics | Plug-on or built-in voltage divider; optional preamplifier/line driver with a 50 Ω output for over 100 m of cable2 |
The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.