Products

Product catalogue

Search and filter detectors, measurement instruments, electronics and software. Every technical value is taken from the manufacturers’ own documents and referenced to its source.

Not sure what you need? Try the instrument finder
156 products

Products

NewFlint USB
BrightSpec

Flint USB

Integrated gamma probe: SiPM scintillation detector and digital MCA in one housing

Detector type
Scintillator with SiPM; standard round NaI(Tl), 2 × 2 or 3 × 3 in; can be ordered with CsI(Tl), CeBr₃, LaBr₃(Ce), LBC or SrI₂
Spectrum channels
256, 512, 1,024, 2,048 or 4,096, 32-bit depth per channel
13 referenced values
SaphyRAD S
Bertin

SaphyRAD S

Dose rate & contamination

Energy range
50 keV–3 MeV
IP rating
IP65
Weight
620 g
13 referenced values
FOOMON
ELSE NUCLEAR

FOOMON

Food monitoring

Detector type
2 × 2 inch NaI(Tl)
Total weight
Approximately 22 kg
IP rating
IP67 during transport with closed lid; IP65 in operating setup
12 referenced values
Model 26 Friskers
Ludlum

Model 26 Friskers

Contamination monitoring

Detector type
Integrated pancake GM
Energy range
16.3 keV–1.3 MeV
Count-rate range
0.1 cps–1.99 kcps; 1 cpm–99.9 kcpm
12 referenced values
H Series
H3D

H Series

Gamma imaging

Detector type
CZT (CdZnTe)
Spectroscopy energy range
50–3000 keV (H100/H400/H420/H1600)
IP rating
H100/H400/H420/H1600: IP67 (excluding external media)
9 models
Detective DX1
ORTEC

Detective DX1

Portable HPGe spectroscopy

Detector type
P-type coaxial HPGe detector
Energy range
DX1/DX1-N: 40 keV–3 MeV; DX1-8/DX1-8-N: 40 keV–8 MeV
Weight
7.23 kg gamma; 7.87 kg gamma/neutron
4 models
RADEAGLET-R
ORTEC

RADEAGLET-R

Handheld isotope identification

Detector type
NaI(Tl) or LaBr₃(Ce), model dependent
Energy range, NaI
NaI: 15 keV–3 MeV
Spectrum channels
2,048
12 models
PAM-100 / PAM-170
Bertin · Bertin VF Nuclear

PAM-100 / PAM-170

Portable activity meters

Detector type
Plastic scintillator and/or ZnS(Ag), variant dependent
Active area
PAM-100: 100 cm²; PAM-170: 170 cm²
20 models
A Series (A400) RIID
H3D

A Series (A400) RIID

Handheld RIID

Detector type
A400: CZT (CdZnTe)
Spectroscopy energy range
A400: 50–3000 keV
Weight
A400: 1.2 kg
6 models
RADEAGLE
ORTEC

RADEAGLE

Handheld isotope identification

Detector type
NaI(Tl) or LaBr₃(Ce), model dependent
Energy range
11 keV–3 MeV
Spectrum channels
2,048
20 models
Emergency Response Kit 2
Rotem

Emergency Response Kit 2

Emergency response case with a RAM R-200 and external probes

Kit contents
Plastic suitcase with a RAM R-200, RG-10 or RG-12, RG-40, PA-100, short telescopic pole, cables meter–detector, meter–PC and detector–PC, batteries and booklet
1 referenced value
Emergency Response Kit 1
Rotem

Emergency Response Kit 1

Emergency response case with a RAM R-200 and external probes

Kit contents
Plastic suitcase with a RAM R-200, one probe (RG-10, RG-12 or RG-40), cables meter–detector, meter–PC and detector–PC, batteries and booklet
1 referenced value
PM-33 Detector
Rotem

PM-33 Detector

Highly sensitive 3 × 3 inch NaI(Tl) probe for environmental gamma monitoring

Energy range
Gamma above 50 keV
Measurement range
Stand-alone: background to 10 µSv/h; as environmental monitor with the TeleMeter: background to 15 mSv/h
Count-rate range
0–50,000 cps
9 referenced values
PM-11 Detector
Rotem

PM-11 Detector

Sensitive NaI(Tl) gamma probe, Rotem’s primary effluent detector in WebiSmarts

Detector
NaI(Tl), 5.1 × 5.1 cm (2 × 2 in); magnetically shielded 5.1 cm photomultiplier
Energy range
Gamma above 50 keV; recommended 30 keV – 3.0 MeV
Count-rate range
0–50,000 cps
8 referenced values
PM-10 Detector
Rotem

PM-10 Detector

Thin NaI(Tl) probe for low-energy gamma and X-rays, optimised for I-125

Detector
NaI(Tl), 2 in diameter × 0.04 in; 1 mil (0.001 in) aluminium window
Energy range
Low-energy gamma, 10–80 keV
Count-rate range
0–50,000 cps
8 referenced values
RP-11 Detector
Rotem

RP-11 Detector

Highly sensitive NaI(Tl) gamma probe for the RAM R-200 or stand-alone

Detector
NaI(Tl), 2 × 2 in, hermetically sealed, with a 2-inch photomultiplier
Energy range
Gamma above 50 keV
Count-rate range
0–50,000 cps
9 referenced values
PA-100 Detector
Rotem

PA-100 Detector

Air proportional alpha detector with a 100 cm² sensitive area

Detector
Air proportional alpha detector
Weight
1 kg
9 referenced values
IC-10 Detector
Rotem

IC-10 Detector

Rugged ion chamber detector for gamma, X-ray and beta radiation

Detector
Ion chamber, 500 cc; wall and cover 300 mg/cm² (tissue equivalent); end window 7 mg/cm²
Measurement range
1 µSv/h – 250 mSv/h (0.1 mR/h – 25 R/h)
Weight
470 g
10 referenced values
GM-10 Detector
Rotem

GM-10 Detector

Pancake GM probe for alpha, beta and gamma surface contamination

Detector
Pancake GM tube LND 73118 or equivalent; mica window 1.5–2.0 mg/cm² behind a fine stainless-steel wire mesh
Count-rate range
0–42,000 cps
Weight
370 g (0.8 lb)
8 referenced values
RG-40 Detector
Rotem

RG-40 Detector

GM probe for high gamma fields, up to 100 Sv/h, for the RAM R-200

Detector
GM tube 4G60M
Measurement range
1 mSv/h – 100 Sv/h (0.1–10,000 R/h)
Weight
130 g (0.3 lb)
9 referenced values
RG-12 Detector
Rotem

RG-12 Detector

Small pancake GM probe for alpha, beta, gamma and X-ray contamination, for the RAM R-200

Detector
GM tube LND 7231
Measurement range
0–1.00 Mcpm
Weight
280 g (0.6 lb)
11 referenced values
RG-10 Detector
Rotem

RG-10 Detector

Pancake GM probe for alpha, beta, gamma and X-ray contamination, for the RAM R-200

Detector
Pancake GM tube NRC 2006
Measurement range
0–1.00 Mcpm
Weight
310 g (0.7 lb)
11 referenced values
RAM DA3-2000 Meter
Rotem

RAM DA3-2000 Meter

Smart meter for a range of interchangeable external detectors, with internal GM detector

Detector
Internal detector (DA3-2000): two energy-compensated GM tubes, ZP1201 and ZP1313 (air kerma) or ZP1202 and ZP1314 (H*(10)); DA 2000 without internal detector
Measurement range
0.5 µSv/h – 1 Sv/h (50 µR/h – 100 R/h), internal detector
Weight
1.5 kg including batteries and internal detectors
14 referenced values
RAM R-200 Meter
Rotem

RAM R-200 Meter

Rugged multipurpose survey meter for wide-range gamma and contamination

Detector
Two energy-compensated GM tubes: ZP-1202 and ZP1314 (or equivalent)
Measurement range
Internal detectors: 0.1 µSv/h – 1 Sv/h (10 µR/h – 100 R/h); with external probes gamma up to 100 Sv/h and alpha/beta 0–1 Mcpm
Weight
460 g including battery
15 referenced values
Showing 24 of 156