NewFlint USB
BrightSpec

Flint USB

Integrated gamma probe: SiPM scintillation detector and digital MCA in one housing

Detector type
Scintillator with SiPM; standard round NaI(Tl), 2 × 2 or 3 × 3 in; can be ordered with CsI(Tl), CeBr₃, LaBr₃(Ce), LBC or SrI₂
Spectrum channels
256, 512, 1,024, 2,048 or 4,096, 32-bit depth per channel
13 referenced values
NewLabVision 4 ( LVis )
ORTEC

LabVision 4 ( LVis )

Software · analysis

Primary function
Nuclear spectrometry counting-laboratory management
Analysis engine
GammaVision and the tRAYcy Monte Carlo algorithm
Measurement workflow
Single-detector and automated multi-detector workflows
8 referenced values
SaphyRAD S
Bertin

SaphyRAD S

Dose rate & contamination

Energy range
50 keV–3 MeV
IP rating
IP65
Weight
620 g
13 referenced values
FOOMON
ELSE NUCLEAR

FOOMON

Food monitoring

Detector type
2 × 2 inch NaI(Tl)
Total weight
Approximately 22 kg
IP rating
IP67 during transport with closed lid; IP65 in operating setup
12 referenced values
Model 26 Friskers
Ludlum

Model 26 Friskers

Contamination monitoring

Detector type
Integrated pancake GM
Energy range
16.3 keV–1.3 MeV
Count-rate range
0.1 cps–1.99 kcps; 1 cpm–99.9 kcpm
12 referenced values
Möbius Recycler
ORTEC

Möbius Recycler

HPGe detector cooling

Weight
28.58 kg empty; 51.26 kg full, excluding cryostat and detector
LN₂ hold time during power loss
Full dewar, typical detector: Streamline about 7–10 days; PopTop about 4–7 days
4 models
GEM HPGe-detektorer
ORTEC

GEM HPGe-detektorer

HPGe detectors for gamma spectroscopy

Energy range
Approximately 40 keV and above
Relative efficiency
10–150% across the model series; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.80–1.30 keV for GEM10–GEM150; model-dependent
17 models
PAM-100 / PAM-170
Bertin · Bertin VF Nuclear

PAM-100 / PAM-170

Portable activity meters

Detector type
Plastic scintillator and/or ZnS(Ag), variant dependent
Active area
PAM-100: 100 cm²; PAM-170: 170 cm²
20 models
Ludlum Model 3003
Ludlum

Ludlum Model 3003

SCA and detector readout

Weight excluding detectors and clips
0.9 kg
Enclosure rating and conditions
IP53
5 models
Alfa- och betakällor
Orano LEA

Alfa- och betakällor

Calibration sources

Radiation
Alpha or beta
Source formats
Point sources and wide areas: discs, planchets, rectangles or squares
Use
Calibration of alpha spectrometers and contamination monitors
10 models
RCAP-2 rekylskyddspaket
ORTEC

RCAP-2 rekylskyddspaket

Alpha spectrometry accessory

Models
RCAP-2-120V; RCAP-2-240V
Supply voltage
RCAP-2-120V: 120 V; RCAP-2-240V: 240 V
Sample-holder bias
−12 V
2 models
Alpha Suite alfaspektrometrar
ORTEC

Alpha Suite alfaspektrometrar

Integrated alpha spectrometry

Energy resolution
≤20 keV FWHM with BU-017-450-100 ULTRA detector and ²⁴¹Am point source; detector-to-source spacing equal to detector diameter
Spectrum channels
Software-selectable conversion gain: 256, 512, 1024, 2048 or 4096 channels
19 models
digiDART
ORTEC

digiDART

Portable digital MCA

Compatible detectors
SMART-1 HPGe detectors; other detectors via a Detector Interface Module (DIM)
Spectrum channels
512–16 k
1 model
928 EASY-NIM
ORTEC

928 EASY-NIM

NIM mca, counter and timer

Spectrum channels
512–16,384, software selectable
Weight
0.9 kg net
3 models
DSPEC 50/50A & 502/502A
ORTEC

DSPEC 50/50A & 502/502A

Digital gamma spectrometer / MCA

Spectrum channels
50/502: 512–16 k; 50A/502A: 256–64 k
Weight
DSPEC 50: 11 kg; DSPEC 502: 11.7 kg
4 models
Shallow Hole Probe
ORTEC

Shallow Hole Probe

HPGe gamma detector

Detector type
Configured with GEM, GMX, GLP, PROFILE or Safeguards HPGe
Weight
Approximately 12 lb
LN₂ holding time
Approximately 16 hours with 70 mm endcap
1 model
Dewars and Cryostats
ORTEC

Dewars and Cryostats

HPGe detector cooling

Cooling technology
Liquid nitrogen (LN₂)
Cryostat configurations
Vertical and horizontal dipstick, portable (all-position or multi-orientation Gamma Gage), down-looking, side-looking and J-type, depending on detector configuration
Dewar capacity
Gamma Gage: 1.2/3/5 L; MOD multi-orientation: 3/7 L; side-looking and down-looking: 7.5/13/30 L; dipstick cryostats: 30 L (DWR-30); shallow-hole probe: 0.7 L
43 models
Safeguards planar HPGe-detektor
ORTEC

Safeguards planar HPGe-detektor

Planar HPGe gamma detector

Detector type
Planar HPGe
Energy resolution at 122 keV
Warranted FWHM for SGD-16550P4: 550 eV at 1 kcps, 6 μs; 615 eV at 50 kcps, 1 μs
7 models
Safeguards koaxial HPGe-detektor
ORTEC

Safeguards koaxial HPGe-detektor

HPGe gamma detector

Detector type
HPGe, coaxial or semi-planar by SGD-GEM model
Energy resolution at 122 keV
FWHM maximum limits 0.61–0.80 keV at 1 kcps and optimal shaping; model-dependent
4 models
GLP plana HPGe-detektorer
ORTEC

GLP plana HPGe-detektorer

HPGe gamma detector

Energy range
Approximately 5–300 keV
Active area
Nominally 80–1,000 mm², model-dependent
Energy resolution at 122 keV
FWHM maximum limits 0.51–0.63 keV for the tabulated models
8 models
GWL brunnsdetektorer
ORTEC

GWL brunnsdetektorer

HPGe gamma detector

Detector type
P-type reverse coaxial HPGe well detector
Energy range
Approximately 10 keV–10 MeV
28 models