Products

Product catalogue

Search and filter detectors, measurement instruments, electronics and software. Every technical value is taken from the manufacturers’ own documents and referenced to its source.

Not sure what you need? Try the instrument finder
17 products

Products

Detective DX1
ORTEC

Detective DX1

Portable HPGe spectroscopy

Energy range
DX1/DX1-N: 40 keV–3 MeV; DX1-8/DX1-8-N: 40 keV–8 MeV
Weight
7.23 kg gamma; 7.87 kg gamma/neutron
Detector type
P-type coaxial HPGe detector
4 models
GEM HPGe-detektorer
ORTEC

GEM HPGe-detektorer

HPGe detectors for gamma spectroscopy

Energy range
Approximately 40 keV and above
Relative efficiency
10–150% across the model series; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.80–1.30 keV for GEM10–GEM150; model-dependent
Detector type
P-type coaxial HPGe
17 models
Safeguards planar HPGe-detektor
ORTEC

Safeguards planar HPGe-detektor

Planar HPGe gamma detector

Energy resolution at 122 keV
Warranted FWHM for SGD-16550P4: 550 eV at 1 kcps, 6 μs; 615 eV at 50 kcps, 1 μs
Detector type
Planar HPGe
7 models
Safeguards koaxial HPGe-detektor
ORTEC

Safeguards koaxial HPGe-detektor

HPGe gamma detector

Energy resolution at 122 keV
FWHM maximum limits 0.61–0.80 keV at 1 kcps and optimal shaping; model-dependent
Detector type
HPGe, coaxial or semi-planar by SGD-GEM model
4 models
GLP plana HPGe-detektorer
ORTEC

GLP plana HPGe-detektorer

HPGe gamma detector

Energy range
Approximately 5–300 keV
Active area
Nominally 80–1,000 mm², model-dependent
Energy resolution at 122 keV
FWHM maximum limits 0.51–0.63 keV for the tabulated models
Detector type
Planar HPGe (LEPS)
8 models
GWL brunnsdetektorer
ORTEC

GWL brunnsdetektorer

HPGe gamma detector

Energy range
Approximately 10 keV–10 MeV
Detector type
P-type reverse coaxial HPGe well detector
28 models
GAMMA-X (GMX) HPGe-detektorer
ORTEC

GAMMA-X (GMX) HPGe-detektorer

HPGe gamma detector

Energy range
Approximately 5 keV–10 MeV
Relative efficiency
10–100%; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.85–1.40 keV for GMX10–GMX100; model-dependent; optimal shaping with DSPEC-50A
Detector type
N-type coaxial HPGe
12 models
PROFILE GEM HPGe-detektorer
ORTEC

PROFILE GEM HPGe-detektorer

HPGe gamma detector

Relative efficiency
Model-dependent: nominal 7–175% (GEM-M, -S, -SP); minimum 10–175% (GEM-C)
Detector type
P-type HPGe; coaxial or semi-planar
34 models
AURAS 3000
ELSE NUCLEAR

AURAS 3000

Free-release assay of large waste containers with up to four HPGe

Energy range
HPGe: 30 keV–7 MeV
Energy resolution at 1.33 MeV
HPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)
Relative efficiency
15–150% (nitrogen-cooled), 50–150% (electro-cooled)
Detector type
Up to four electro- or nitrogen-cooled HPGe detectors on two movable towers (up to two e …
13 referenced values
ADAMOS
ELSE NUCLEAR

ADAMOS

Automated segmented gamma scanning of waste drums

Energy range
HPGe: 30 keV–7 MeV
Energy resolution at 1.33 MeV
HPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)
Relative efficiency
15–150% (nitrogen-cooled), 50–150% (electro-cooled)
Detector type
Typically a collimated high-efficiency HPGe detector with MCA on a vertically moving she …
13 referenced values
ISO-CART-II LN2
ORTEC

ISO-CART-II LN2

Mobile in-situ assay systems with LN₂-cooled HPGe detectors

Detector type
ORTEC LN₂-cooled HPGe detectors, typically large-volume GEM (p-type) or GMX (n-type); re …
7 referenced values
ISO-CART-85
ORTEC

ISO-CART-85

Mobile in-situ waste assay system with Stirling-cooled HPGe

Relative efficiency
Approx. 50% (the HPGe detector in the IDM-200-V)
Detector type
IDM-200-V: integrated very-large-area HPGe spectrometer, Stirling cooled (no liquid nitr …
9 referenced values
FoodGuard-2
ORTEC

FoodGuard-2

HPGe workstation for quantitative determination of radionuclides in food

Relative efficiency
20–60%; detector and cooling chosen when ordering
Detector type
High-resolution HPGe detector
9 referenced values
CSS-D-60 Compton Suppression System
ORTEC

CSS-D-60 Compton Suppression System

Compton-suppressed HPGe system for low-background counting

Relative efficiency
60% by default; other detector sizes up to 60% as options
Detector type
N-type HPGe (GMX) with carbon-fibre endcap, max. Ø83 mm (3.25 in), and low-background Al …
9 referenced values
VEBOS helkroppsräknare
ELSE NUCLEAR

VEBOS helkroppsräknare

In-vivo counting system

Total weight
Approximately 1000 kg
Detector type
HPGe or NaI(Tl), according to selected configuration
16 referenced values
ACTINIDE-85 lungdetektor
ORTEC

ACTINIDE-85 lungdetektor

HPGe gamma detector

Energy range
Photon energies above 3 keV
Active front area
Over 54 cm²
Energy resolution at 122 keV
≤700 eV FWHM (warranted), at optimal shaping time with an ORTEC DSPEC-50A; consult factory for performance with ICS cooling
Detector type
HPGe, based on PROFILE S8530
11 referenced values
TETRAD-20 HPGe-detektor
ORTEC

TETRAD-20 HPGe-detektor

HPGe gamma detector

Energy range
20 keV–10 MeV
Relative efficiency
TETRAD-20: 20% per detector element
Energy resolution at 122 keV
TETRAD-20: ≤1.30 keV FWHM per element
Detector type
N-type coaxial HPGe, clover geometry
10 referenced values