ADAMOS

Automated segmented gamma scanning of waste drums

Automated segmented gamma scanning system that characterises drums filled with radioactive waste. The drum is centred and weighed on a rotating platform, and collimated detectors – typically HPGe – move vertically to measure preset sub-sections. Efficiency is pre-calculated with Monte Carlo simulations from the set-up and the density of the drum content; the layout is adapted to the customer’s needs.

Energy range
HPGe: 30 keV–7 MeV2
Energy resolution at 1.33 MeV
HPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)2
Relative efficiency
15–150% (nitrogen-cooled), 50–150% (electro-cooled)2
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Measurement set-up selected automatically by activity level
  • Hot-spot detection
  • Safety by design with perimeter protection and emergency buttons

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeTypically a collimated high-efficiency HPGe detector with MCA on a vertically moving shelf; can be combined with GM tubes (fast dose rate), large plastic scintillators (pre-scan) or NaI(Tl) instead of HPGe2

Performance

Energy resolution at 1.33 MeVHPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)2
Relative efficiency15–150% (nitrogen-cooled), 50–150% (electro-cooled)2

Measuring range

Energy rangeHPGe: 30 keV–7 MeV2

Cooling

CoolingElectro-cooling or liquid nitrogen2

Software & data

SoftwareEfficiency pre-calculated with Monte Carlo simulations from the set-up and the density of the drum content; the report may include correlated isotope concentrations and possible hot-spot locations2

Mechanical

Drum sizeDrums up to 500 L and 2,500 kg, density up to 2 g/cm³1
WeightTypical: conveyors 250 kg each, central platform 1,000 kg, detector frame 1,000 kg, electric axes 230 kg each, switchboard 200 kg2

Ordering & accessories

ConfigurationsHPGe/L-D (2 + 2 conveyors and density measurement with a ²²Na source), HPGe/U (U-shaped array for up to 8 drums), HPGe-GM (one HPGe with GM fast scan) and HPGe-2G (two HPGe in 90° geometry)2

General

UseAutomated segmented gamma scanning to characterise drums filled with radioactive waste1
ScaleWeighing station max. payload 2,500 kg, precision ±2.5 kg2
Measurement sequenceThe drum is centred and weighed on a rotating platform; detectors move vertically and scan preset sub-sections through a collimator; the measurement set-up is selected automatically by activity level1
ControlLocal PLC and operator panel; the software runs the work cycle and checks the system status1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ELSE NUCLEARProduct page Product page Checked 2026-10-16
  2. 2
    Publisher: ELSE NUCLEARDatasheet p. 3, Detection equipment; p. 3, HPGe features; p. 2, Mechanical specifications; p. 3, Management software … Checked 2026-10-16
AURAS 3000
ELSE NUCLEAR

AURAS 3000

Free-release assay of large waste containers with up to four HPGe

Energy range
HPGe: 30 keV–7 MeV
Energy resolution at 1.33 MeV
HPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)
Relative efficiency
15–150% (nitrogen-cooled), 50–150% (electro-cooled)
13 referenced values
ISO-TURNTABLE
ORTEC

ISO-TURNTABLE

Drum rotator for gamma assay of waste drums

Weight
Shipping weight 200 lb
9 referenced values
FREE-AND 16
ELSE NUCLEAR

FREE-AND 16

Spectrometric station with 16 NaI(Tl) for waste characterisation

Detector type
16 NaI(Tl) 3 × 3 in crystals with PMT and MCA, eight on each side in two arrays
9 referenced values
ARCHIMEDES III
ELSE NUCLEAR

ARCHIMEDES III

Portal monitor for excavation materials in boxes and containers

Detector type
Four plastic scintillators 100 × 50 × 5 cm
Active area
5000 cm² per detector; two pairs mounted on the sides of the portal
Energy range
35 keV–2 MeV
8 referenced values