AURAS 3000

Free-release assay of large waste containers with up to four HPGe

Automated system that scans and characterises waste in bags, boxes, drums and B25 containers for free release. Up to four HPGe detectors on two movable towers measure the container in sub-sections while a heavy-duty platform moves it through the measurement area. The software reports activity, MDA and a release index per nuclide against customisable limits, and adds hard-to-measure nuclides via scaling factors.

Energy range
HPGe: 30 keV–7 MeV1
Energy resolution at 1.33 MeV
HPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)1
Relative efficiency
15–150% (nitrogen-cooled), 50–150% (electro-cooled)1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Only five operator inputs for a routine scan
  • Detector height set automatically with 1 mm resolution
  • Safety by design; the PLC stops motors on a safety input

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeUp to four electro- or nitrogen-cooled HPGe detectors on two movable towers (up to two each)1
Detector positioningHeight set automatically with 1 mm resolution by container size; towers positioned manually at the recommended distance1

Performance

Energy resolution at 1.33 MeVHPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)1
Relative efficiency15–150% (nitrogen-cooled), 50–150% (electro-cooled)1

Measuring range

Energy rangeHPGe: 30 keV–7 MeV1

Cooling

CoolingStirling or nitrogen cooler; hardened cryostats that can be temperature cycled at any time and restart automatically after power loss1
Load capacityContainers up to 3 m³ (B-25 ISO), max. 3,000 kg; weighing system with 1 kg resolution1

Software & data

SoftwareRelease index per nuclide against customisable limit tables; scaling factors add low or non-gamma-emitting nuclides; final report with hot spots1

Mechanical

DimensionsTypically 8.8 × 5.5 × 2.5 m (L × W × H)1
Total weightTypically 5,000 kg1

General

UseScanning and characterisation of waste in bags, boxes, drums and B25 containers (density 100–2000 kg/m³) for free release1
MDA0.0037 Bq/g for ¹³⁷Cs (40 min)2
ResultsSpectra per detector and position, container activity per detector and averaged, hot spots and MDA values2

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: ELSE NUCLEARDatasheet p. 1; p. 2, HPGe specifications; p. 2, Detection equipment; p. 2, Mechanical structure … Checked 2026-10-16
  2. 2
    Publisher: ELSE NUCLEARProduct page Product page Checked 2026-10-16
ADAMOS
ELSE NUCLEAR

ADAMOS

Automated segmented gamma scanning of waste drums

Energy range
HPGe: 30 keV–7 MeV
Energy resolution at 1.33 MeV
HPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)
Relative efficiency
15–150% (nitrogen-cooled), 50–150% (electro-cooled)
13 referenced values
ISO-CART-85
ORTEC

ISO-CART-85

Mobile in-situ waste assay system with Stirling-cooled HPGe

Detector type
IDM-200-V: integrated very-large-area HPGe spectrometer, Stirling cooled (no liquid nitrogen)
Relative efficiency
Approx. 50% (the HPGe detector in the IDM-200-V)
9 referenced values
FREE-AND 16
ELSE NUCLEAR

FREE-AND 16

Spectrometric station with 16 NaI(Tl) for waste characterisation

Detector type
16 NaI(Tl) 3 × 3 in crystals with PMT and MCA, eight on each side in two arrays
9 referenced values
ARCHIMEDES III
ELSE NUCLEAR

ARCHIMEDES III

Portal monitor for excavation materials in boxes and containers

Detector type
Four plastic scintillators 100 × 50 × 5 cm
Active area
5000 cm² per detector; two pairs mounted on the sides of the portal
Energy range
35 keV–2 MeV
8 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.