Search and filter detectors, measurement instruments, electronics and software. Every technical value is taken from the manufacturers’ own documents and referenced to its source.

Not sure what you need? Try the instrument finder
210 products

Products

SaphyRAD S
Bertin

SaphyRAD S

Dose rate & contamination

Energy range
50 keV–3 MeV
IP rating
IP65
Weight
620 g
13 referenced values
H Series
H3D

H Series

Gamma imaging

Detector type
CZT (CdZnTe)
Spectroscopy energy range
50–3000 keV (H100/H400/H420/H1600)
IP rating
H100/H400/H420/H1600: IP67 (excluding external media)
9 models
Detective DX1
ORTEC

Detective DX1

Portable HPGe spectroscopy

Detector type
P-type coaxial HPGe detector
Energy range
DX1/DX1-N: 40 keV–3 MeV; DX1-8/DX1-8-N: 40 keV–8 MeV
Weight
7.23 kg gamma; 7.87 kg gamma/neutron
4 models
RADEAGLET-R
ORTEC

RADEAGLET-R

Handheld isotope identification

Detector type
NaI(Tl) or LaBr₃(Ce), model dependent
Energy range, NaI
NaI: 15 keV–3 MeV
Spectrum channels
2,048
12 models
A Series (A400) RIID
H3D

A Series (A400) RIID

Handheld RIID

Detector type
A400: CZT (CdZnTe)
Spectroscopy energy range
A400: 50–3000 keV
Weight
A400: 1.2 kg
6 models
RADEAGLE
ORTEC

RADEAGLE

Handheld isotope identification

Detector type
NaI(Tl) or LaBr₃(Ce), model dependent
Energy range
11 keV–3 MeV
Spectrum channels
2,048
20 models
POE Ethernet Switch
Rotem

POE Ethernet Switch

PoE network switch (Cisco Catalyst 3560-CX, 8 ports) for WebiSmarts

Weight
2.26 kg
6 referenced values
Advanced Detector Bracket
Rotem

Advanced Detector Bracket

Detector bracket with LEDs and buzzer for local feedback far from the DPU-3

Weight
0.32 kg
4 referenced values
External Signal Interface
Rotem

External Signal Interface

Ethernet relay board for controlling external devices from WebiSmarts

Relay outputs
8 relay channels 250 V AC/10 A, individually controlled; 8 external control outputs (active low)
Communication
Ethernet TCP/IP (RJ45) with on-board web server; RS-485 networking
Supply voltage
7–24 V DC
3 referenced values
External Light Tower
Rotem

External Light Tower

Light tower showing the highest radiation level from the detectors on a DPU-3

IP rating
IP65 (IEC 60529), NEMA type 4X and 13
5 referenced values
Main Control Workstation
Rotem

Main Control Workstation

Workstation for WebiSmarts, with minimum requirements for a local or virtual machine

System components
ThinkStation P360 Ultra: 32 GB RAM, 1 TB hard drive, 7 USB ports including 2 Thunderbolt 4
Minimum requirements for WebiSmarts
Local machine: i9-13900K (24 cores), Windows 11 Pro or Windows Server 2022, 32 GB DDR5, 1 TB SSD; virtual machine: 12 vCPUs, 32 GB, 1 TB
Firewall ports
5000, 8080 and 15386
3 referenced values
Emergency Response Kit 2
Rotem

Emergency Response Kit 2

Emergency response case with a RAM R-200 and external probes

Kit contents
Plastic suitcase with a RAM R-200, RG-10 or RG-12, RG-40, PA-100, short telescopic pole, cables meter–detector, meter–PC and detector–PC, batteries and booklet
1 referenced value
Emergency Response Kit 1
Rotem

Emergency Response Kit 1

Emergency response case with a RAM R-200 and external probes

Kit contents
Plastic suitcase with a RAM R-200, one probe (RG-10, RG-12 or RG-40), cables meter–detector, meter–PC and detector–PC, batteries and booklet
1 referenced value
PM-11 Detector
Rotem

PM-11 Detector

Sensitive NaI(Tl) gamma probe, Rotem’s primary effluent detector in WebiSmarts

Detector
NaI(Tl), 5.1 × 5.1 cm (2 × 2 in); magnetically shielded 5.1 cm photomultiplier
Energy range
Gamma above 50 keV; recommended 30 keV – 3.0 MeV
Count-rate range
0–50,000 cps
8 referenced values
Neutron Area Monitor
Rotem

Neutron Area Monitor

Wall-mounted neutron detector (Ludlum 42-30H) for area monitoring in WebiSmarts

Detector
Proportional neutron detector Ludlum Model 42-30H; moderator: polyethylene sphere ø25.4 cm
Energy range
Thermal to approx. 12 MeV
Weight
8.8 kg (19.5 lb)
11 referenced values
GM-42 Detector
Rotem

GM-42 Detector

Sensitive low-range GM gamma detector for clean rooms and radiopharmacies

Detector
GM tube ZP-1201 or equivalent
Measurement range
0.5 µSv/h – 10 mSv/h (50 µR/h – 1 R/h)
Energy range
50 keV – 1.3 MeV
9 referenced values
GM-41 Detector
Rotem

GM-41 Detector

GM gamma detector for high fields, e.g. in cyclotron bunkers and hot cells

Detector
GM tube ZP-1313 or equivalent
Measurement range
50 µSv/h – 1 Sv/h (5 mR/h – 100 R/h)
Energy range
50 keV – 1.3 MeV
10 referenced values
GM-40 Detector
Rotem

GM-40 Detector

GM gamma detector for very high fields, 250 µSv/h – 10 Sv/h

Detector
GM tube ZP1301
Measurement range
250 µSv/h – 10 Sv/h (25 mR/h – 1,000 R/h)
Energy range
50 keV – 1.3 MeV
8 referenced values
Wide Range External Gamma Beta Detector
Rotem

Wide Range External Gamma Beta Detector

Smart wide-range gamma and beta detector for WebiSmarts, 0.5 µSv/h – 10 Sv/h

Detector
GM tubes ZP-1301 and ZP-1400 (or equivalent)
Measurement range
0.5 µSv/h – 10 Sv/h (50 µR/h – 1,000 R/h)
Energy range
Gamma 50 keV – 2 MeV
11 referenced values
Wide Range External Gamma Detector
Rotem

Wide Range External Gamma Detector

Smart wide-range gamma detector for WebiSmarts, 0.5 µSv/h – 10 Sv/h

Detector
GM tubes ZP-1301 and ZP-1201 (or equivalent)
Measurement range
0.5 µSv/h – 10 Sv/h (50 µR/h – 1,000 R/h)
Energy range
Gamma 50 keV – 2 MeV
11 referenced values
EnviSmarts
Rotem

EnviSmarts

Indoor and outdoor environmental monitoring with stand-alone monitors and online software

Measurement range
PM-33 monitor: background to 15 mSv/h (1.5 R/h), the detector up to 10 µSv/h and then the TeleMeter’s GM tube; RP-33 monitor: background to 1 Sv/h (100 R/h) with the RAM R-200’s GM tubes from 10 µSv/h
3 referenced values
Coincidence Exhaust Stack Monitoring
Rotem

Coincidence Exhaust Stack Monitoring

Two-detector coincidence system for very low emissions in the exhaust stack

Detector
PM-11M gamma detector (NaI(Tl), 2 × 2 in), beta detector (plastic scintillator for positron identification) and GM-42 high-range GM detector; plus a flow meter
2 referenced values
WebiMissions Software
Rotem

WebiMissions Software

Software for collecting and reporting effluent emissions with existing detectors

Primary function
Collecting, storing, displaying and reporting effluent emissions with existing detectors (derived from WebiSmarts)
Functions
With the PM-11 coincidence system: reports only effluent within the exhaust duct; identifies F-18, Ga-68, O-15, C-11, N-13, I-131, Tc-99m, Ga-67, Tl-201, I-125 and Lu-177
2 referenced values
WebiSmarts System
Rotem

WebiSmarts System

Web-based area and stack monitoring system with DPU-3 monitors

Primary function
Web software that receives online data from DPU-3 area monitors and shows them on colour-coded maps
Functions
One year of history per point; isotope identification of effluent; over 20 maps; real-time background subtraction; dose and dose rate at the same time
System components
Web software, DPU-3 monitors (four detectors each) and a stack monitor; maps, points and history are stored on a server and accessed with a browser
4 referenced values