GM-42 Detector

Sensitive low-range GM gamma detector for clean rooms and radiopharmacies

Sensitive low-range gamma detector for measuring dose rates where radioactive material is handled, such as clean rooms, radiopharmacies, QA departments and packing rooms, and as a backup to the extremely sensitive PM-11 exhaust stack detector. Like all WebiSmarts detectors it contains its calibration factor and a unique electronic identifier.

Detector
GM tube ZP-1201 or equivalent1
Measurement range
0.5 µSv/h – 10 mSv/h (50 µR/h – 1 R/h)1
Energy range
50 keV – 1.3 MeV1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

DetectorGM tube ZP-1201 or equivalent1

Measuring range

Measurement range0.5 µSv/h – 10 mSv/h (50 µR/h – 1 R/h)1
Energy range50 keV – 1.3 MeV1
Energy response±20%1
Angular dependenceLess than ±20% within ±45° of the preferred direction1

Electronics & signal

Signal outputsTTL pulses (5 V, 5 ms); status: identification, malfunction, overflow; cable up to 100 m2

Mechanical

Dimensions197 × ø38 mm1
Weight250 g (0.55 lb)1

Environment & ratings

Operating temperature−10 to +50 °C1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: Rotem IndustriesDatasheet TDS Checked 2026-10-16
  2. 2
    Publisher: Rotem IndustriesProduct page Product page – Technical Specifications Checked 2026-10-16
GM-40 Detector
Rotem

GM-40 Detector

GM gamma detector for very high fields, 250 µSv/h – 10 Sv/h

Detector
GM tube ZP1301
Measurement range
250 µSv/h – 10 Sv/h (25 mR/h – 1,000 R/h)
Energy range
50 keV – 1.3 MeV
8 referenced values
GM-41 Detector
Rotem

GM-41 Detector

GM gamma detector for high fields, e.g. in cyclotron bunkers and hot cells

Detector
GM tube ZP-1313 or equivalent
Measurement range
50 µSv/h – 1 Sv/h (5 mR/h – 100 R/h)
Energy range
50 keV – 1.3 MeV
10 referenced values
PM-11 Detector
Rotem

PM-11 Detector

Sensitive NaI(Tl) gamma probe, Rotem’s primary effluent detector in WebiSmarts

Detector
NaI(Tl), 5.1 × 5.1 cm (2 × 2 in); magnetically shielded 5.1 cm photomultiplier
Energy range
Gamma above 50 keV; recommended 30 keV – 3.0 MeV
Count-rate range
0–50,000 cps
8 referenced values
DPU-3 Meter
Rotem

DPU-3 Meter

Ethernet area monitor with PoE for WebiSmarts, with or without an internal detector

Measurement range
Internal low-range detector: 0.1 µSv/h – 40 mSv/h (0.01 mR/h – 4 R/h); wide-range detector: 0.1 µSv/h – 10 Sv/h (0.01 mR/h – 1,000 R/h)
Detector
One internal and three external detectors, recognised automatically (also available without an internal detector)
Weight
DPU-3: 1.7 kg
11 referenced values