POE Ethernet Switch

PoE network switch (Cisco Catalyst 3560-CX, 8 ports) for WebiSmarts

Network switch that carries all data from the DPU-3 monitors to the WebiSmarts computer and powers the monitors via PoE. Rotem offers several sizes; the most popular is the Cisco Catalyst 3560-CX with 8 PoE ports.

Weight
2.26 kg1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Communication8 × RJ-45 with PoE and 2 × SFP1
Power supplyPoE+ with up to 240 W PoE budget; can power 8 monitors simultaneously2
Power consumption25.4 W (typical)1
Dimensions4.3 × 27 × 23.8 cm (H × W × D)1
Weight2.26 kg1
Ordering codeBAK-38162

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: Rotem IndustriesProduct page Product page – Technical Information Checked 2026-10-16
  2. 2
    Publisher: Rotem IndustriesDatasheet TDS Checked 2026-10-16
DPU-3 Meter
Rotem

DPU-3 Meter

Ethernet area monitor with PoE for WebiSmarts, with or without an internal detector

Measurement range
Internal low-range detector: 0.1 µSv/h – 40 mSv/h (0.01 mR/h – 4 R/h); wide-range detector: 0.1 µSv/h – 10 Sv/h (0.01 mR/h – 1,000 R/h)
Detector
One internal and three external detectors, recognised automatically (also available without an internal detector)
Weight
DPU-3: 1.7 kg
11 referenced values
WebiSmarts System
Rotem

WebiSmarts System

Web-based area and stack monitoring system with DPU-3 monitors

Primary function
Web software that receives online data from DPU-3 area monitors and shows them on colour-coded maps
Functions
One year of history per point; isotope identification of effluent; over 20 maps; real-time background subtraction; dose and dose rate at the same time
System components
Web software, DPU-3 monitors (four detectors each) and a stack monitor; maps, points and history are stored on a server and accessed with a browser
4 referenced values
Main Control Workstation
Rotem

Main Control Workstation

Workstation for WebiSmarts, with minimum requirements for a local or virtual machine

System components
ThinkStation P360 Ultra: 32 GB RAM, 1 TB hard drive, 7 USB ports including 2 Thunderbolt 4
Minimum requirements for WebiSmarts
Local machine: i9-13900K (24 cores), Windows 11 Pro or Windows Server 2022, 32 GB DDR5, 1 TB SSD; virtual machine: 12 vCPUs, 32 GB, 1 TB
Firewall ports
5000, 8080 and 15386
3 referenced values
Advanced Detector Bracket
Rotem

Advanced Detector Bracket

Detector bracket with LEDs and buzzer for local feedback far from the DPU-3

Weight
0.32 kg
4 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.