HPGe & gamma spectroscopy

HPGe detectors

Coaxial, planar and well detectors, p-type and n-type.

16 products

Products

GEM HPGe-detektorer
ORTEC

GEM HPGe-detektorer

HPGe detectors for gamma spectroscopy

Energy range
Approximately 40 keV and above
Relative efficiency
10–150% across the model series; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.80–1.30 keV for GEM10–GEM150; model-dependent
17 models
Safeguards planar HPGe-detektor
ORTEC

Safeguards planar HPGe-detektor

Planar HPGe gamma detector

Detector type
Planar HPGe
Energy resolution at 122 keV
Warranted FWHM for SGD-16550P4: 550 eV at 1 kcps, 6 μs; 615 eV at 50 kcps, 1 μs
7 models
Safeguards koaxial HPGe-detektor
ORTEC

Safeguards koaxial HPGe-detektor

HPGe gamma detector

Detector type
HPGe, coaxial or semi-planar by SGD-GEM model
Energy resolution at 122 keV
FWHM maximum limits 0.61–0.80 keV at 1 kcps and optimal shaping; model-dependent
4 models
GLP plana HPGe-detektorer
ORTEC

GLP plana HPGe-detektorer

HPGe gamma detector

Energy range
Approximately 5–300 keV
Active area
Nominally 80–1,000 mm², model-dependent
Energy resolution at 122 keV
FWHM maximum limits 0.51–0.63 keV for the tabulated models
8 models
GWL brunnsdetektorer
ORTEC

GWL brunnsdetektorer

HPGe gamma detector

Detector type
P-type reverse coaxial HPGe well detector
Energy range
Approximately 10 keV–10 MeV
28 models
GAMMA-X (GMX) HPGe-detektorer
ORTEC

GAMMA-X (GMX) HPGe-detektorer

HPGe gamma detector

Energy range
Approximately 5 keV–10 MeV
Relative efficiency
10–100%; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.85–1.40 keV for GMX10–GMX100; model-dependent; optimal shaping with DSPEC-50A
12 models
PROFILE GEM HPGe-detektorer
ORTEC

PROFILE GEM HPGe-detektorer

HPGe gamma detector

Detector type
P-type HPGe; coaxial or semi-planar
Relative efficiency
Model-dependent: nominal 7–175% (GEM-M, -S, -SP); minimum 10–175% (GEM-C)
34 models
AURAS 3000
ELSE NUCLEAR

AURAS 3000

Free-release assay of large waste containers with up to four HPGe

Energy range
HPGe: 30 keV–7 MeV
Energy resolution at 1.33 MeV
HPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)
Relative efficiency
15–150% (nitrogen-cooled), 50–150% (electro-cooled)
13 referenced values
ADAMOS
ELSE NUCLEAR

ADAMOS

Automated segmented gamma scanning of waste drums

Energy range
HPGe: 30 keV–7 MeV
Energy resolution at 1.33 MeV
HPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)
Relative efficiency
15–150% (nitrogen-cooled), 50–150% (electro-cooled)
13 referenced values
ISO-CART-II LN2
ORTEC

ISO-CART-II LN2

Mobile in-situ assay systems with LN₂-cooled HPGe detectors

Detector type
ORTEC LN₂-cooled HPGe detectors, typically large-volume GEM (p-type) or GMX (n-type); relative efficiencies over 200% available
7 referenced values
ISO-CART-85
ORTEC

ISO-CART-85

Mobile in-situ waste assay system with Stirling-cooled HPGe

Detector type
IDM-200-V: integrated very-large-area HPGe spectrometer, Stirling cooled (no liquid nitrogen)
Relative efficiency
Approx. 50% (the HPGe detector in the IDM-200-V)
9 referenced values
CSS-D-60 Compton Suppression System
ORTEC

CSS-D-60 Compton Suppression System

Compton-suppressed HPGe system for low-background counting

Detector type
N-type HPGe (GMX) with carbon-fibre endcap, max. Ø83 mm (3.25 in), and low-background Al cup
Relative efficiency
60% by default; other detector sizes up to 60% as options
9 referenced values
IDM-200-V
ORTEC

IDM-200-V

Interchangeable HPGe detector module for measurement systems

Relative efficiency
>50% typical (ANSI/IEEE 325-1996)
Energy resolution at 122 keV
≤1400 eV FWHM (warranted at optimum settings)
Energy resolution at 1.33 MeV
≤2.3 keV FWHM at 1,332 keV (warranted at optimum settings)
24 referenced values
Detective DX1-TS
ORTEC

Detective DX1-TS

Portable HPGe spectrometer for in-situ measurements

Relative efficiency
≥40% typical (ANSI/IEEE 325-1996)
Energy resolution at 122 keV
≤1630 eV FWHM (warranted at optimum settings)
Energy resolution at 1.33 MeV
≤2.0 keV FWHM at 1,332 keV (warranted at optimum settings)
22 referenced values
ACTINIDE-85 lungdetektor
ORTEC

ACTINIDE-85 lungdetektor

HPGe gamma detector

Energy range
Photon energies above 3 keV
Active front area
Over 54 cm²
Energy resolution at 122 keV
≤700 eV FWHM (warranted), at optimal shaping time with an ORTEC DSPEC-50A; consult factory for performance with ICS cooling
11 referenced values
TETRAD-20 HPGe-detektor
ORTEC

TETRAD-20 HPGe-detektor

HPGe gamma detector

Energy range
20 keV–10 MeV
Relative efficiency
TETRAD-20: 20% per detector element
Energy resolution at 122 keV
TETRAD-20: ≤1.30 keV FWHM per element
10 referenced values