Nuclear power & nuclear technology

Measurement equipment for operations, radiation protection, waste management and laboratories at nuclear facilities.

Nuclear facilities demand traceability, documentation and long-term support. NDEC supplies detectors, electronics, software and field instruments from established manufacturers and helps put together the right configuration for the measurement task.

Typical needs

  • HPGe gamma spectroscopy in the laboratory
  • Contamination and dose-rate measurement in controlled areas
  • Alpha spectrometry of samples
  • Calibration with certified reference sources

Relevant products

View all (496)
SaphyRAD S
Bertin

SaphyRAD S

Dose rate & contamination

Energy range
50 keV–3 MeV
IP rating
IP65
Weight
620 g
13 referenced values
FOOMON
ELSE NUCLEAR

FOOMON

Food monitoring

Detector type
2 × 2 inch NaI(Tl)
Total weight
Approximately 22 kg
IP rating
IP67 during transport with closed lid; IP65 in operating setup
12 referenced values
Model 26 Friskers
Ludlum

Model 26 Friskers

Contamination monitoring

Detector type
Integrated pancake GM
Energy range
16.3 keV–1.3 MeV
Count-rate range
0.1 cps–1.99 kcps; 1 cpm–99.9 kcpm
12 referenced values
H Series
H3D

H Series

Gamma imaging

Detector type
CZT (CdZnTe)
Spectroscopy energy range
50–3000 keV (H100/H400/H420/H1600)
IP rating
H100/H400/H420/H1600: IP67 (excluding external media)
9 models
Detective DX1
ORTEC

Detective DX1

Portable HPGe spectroscopy

Detector type
P-type coaxial HPGe detector
Energy range
DX1/DX1-N: 40 keV–3 MeV; DX1-8/DX1-8-N: 40 keV–8 MeV
Weight
7.23 kg gamma; 7.87 kg gamma/neutron
4 models
RADEAGLET-R
ORTEC

RADEAGLET-R

Handheld isotope identification

Detector type
NaI(Tl) or LaBr₃(Ce), model dependent
Energy range, NaI
NaI: 15 keV–3 MeV
Spectrum channels
2,048
12 models
Möbius Recycler
ORTEC

Möbius Recycler

HPGe detector cooling

Weight
28.58 kg empty; 51.26 kg full, excluding cryostat and detector
LN₂ hold time during power loss
Full dewar, typical detector: Streamline about 7–10 days; PopTop about 4–7 days
4 models
GEM HPGe-detektorer
ORTEC

GEM HPGe-detektorer

HPGe detectors for gamma spectroscopy

Energy range
Approximately 40 keV and above
Relative efficiency
10–150% across the model series; higher on request
Energy resolution at 122 keV
FWHM maximum limits 0.80–1.30 keV for GEM10–GEM150; model-dependent
17 models
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.