Products

Monitoring & preparedness

Systems for monitoring, screening and dosimetry.

69 products

Products

POE Ethernet Switch
Rotem

POE Ethernet Switch

PoE network switch (Cisco Catalyst 3560-CX, 8 ports) for WebiSmarts

Weight
2.26 kg
6 referenced values
Advanced Detector Bracket
Rotem

Advanced Detector Bracket

Detector bracket with LEDs and buzzer for local feedback far from the DPU-3

Weight
0.32 kg
4 referenced values
External Signal Interface
Rotem

External Signal Interface

Ethernet relay board for controlling external devices from WebiSmarts

Relay outputs
8 relay channels 250 V AC/10 A, individually controlled; 8 external control outputs (active low)
Communication
Ethernet TCP/IP (RJ45) with on-board web server; RS-485 networking
Supply voltage
7–24 V DC
3 referenced values
External Light Tower
Rotem

External Light Tower

Light tower showing the highest radiation level from the detectors on a DPU-3

IP rating
IP65 (IEC 60529), NEMA type 4X and 13
5 referenced values
Main Control Workstation
Rotem

Main Control Workstation

Workstation for WebiSmarts, with minimum requirements for a local or virtual machine

System components
ThinkStation P360 Ultra: 32 GB RAM, 1 TB hard drive, 7 USB ports including 2 Thunderbolt 4
Minimum requirements for WebiSmarts
Local machine: i9-13900K (24 cores), Windows 11 Pro or Windows Server 2022, 32 GB DDR5, 1 TB SSD; virtual machine: 12 vCPUs, 32 GB, 1 TB
Firewall ports
5000, 8080 and 15386
3 referenced values
PM-11 Detector
Rotem

PM-11 Detector

Sensitive NaI(Tl) gamma probe, Rotem’s primary effluent detector in WebiSmarts

Detector
NaI(Tl), 5.1 × 5.1 cm (2 × 2 in); magnetically shielded 5.1 cm photomultiplier
Energy range
Gamma above 50 keV; recommended 30 keV – 3.0 MeV
Count-rate range
0–50,000 cps
8 referenced values
Neutron Area Monitor
Rotem

Neutron Area Monitor

Wall-mounted neutron detector (Ludlum 42-30H) for area monitoring in WebiSmarts

Detector
Proportional neutron detector Ludlum Model 42-30H; moderator: polyethylene sphere ø25.4 cm
Energy range
Thermal to approx. 12 MeV
Weight
8.8 kg (19.5 lb)
11 referenced values
GM-42 Detector
Rotem

GM-42 Detector

Sensitive low-range GM gamma detector for clean rooms and radiopharmacies

Detector
GM tube ZP-1201 or equivalent
Measurement range
0.5 µSv/h – 10 mSv/h (50 µR/h – 1 R/h)
Energy range
50 keV – 1.3 MeV
9 referenced values
GM-41 Detector
Rotem

GM-41 Detector

GM gamma detector for high fields, e.g. in cyclotron bunkers and hot cells

Detector
GM tube ZP-1313 or equivalent
Measurement range
50 µSv/h – 1 Sv/h (5 mR/h – 100 R/h)
Energy range
50 keV – 1.3 MeV
10 referenced values
GM-40 Detector
Rotem

GM-40 Detector

GM gamma detector for very high fields, 250 µSv/h – 10 Sv/h

Detector
GM tube ZP1301
Measurement range
250 µSv/h – 10 Sv/h (25 mR/h – 1,000 R/h)
Energy range
50 keV – 1.3 MeV
8 referenced values
Wide Range External Gamma Beta Detector
Rotem

Wide Range External Gamma Beta Detector

Smart wide-range gamma and beta detector for WebiSmarts, 0.5 µSv/h – 10 Sv/h

Detector
GM tubes ZP-1301 and ZP-1400 (or equivalent)
Measurement range
0.5 µSv/h – 10 Sv/h (50 µR/h – 1,000 R/h)
Energy range
Gamma 50 keV – 2 MeV
11 referenced values
Wide Range External Gamma Detector
Rotem

Wide Range External Gamma Detector

Smart wide-range gamma detector for WebiSmarts, 0.5 µSv/h – 10 Sv/h

Detector
GM tubes ZP-1301 and ZP-1201 (or equivalent)
Measurement range
0.5 µSv/h – 10 Sv/h (50 µR/h – 1,000 R/h)
Energy range
Gamma 50 keV – 2 MeV
11 referenced values
EnviSmarts
Rotem

EnviSmarts

Indoor and outdoor environmental monitoring with stand-alone monitors and online software

Measurement range
PM-33 monitor: background to 15 mSv/h (1.5 R/h), the detector up to 10 µSv/h and then the TeleMeter’s GM tube; RP-33 monitor: background to 1 Sv/h (100 R/h) with the RAM R-200’s GM tubes from 10 µSv/h
3 referenced values
Coincidence Exhaust Stack Monitoring
Rotem

Coincidence Exhaust Stack Monitoring

Two-detector coincidence system for very low emissions in the exhaust stack

Detector
PM-11M gamma detector (NaI(Tl), 2 × 2 in), beta detector (plastic scintillator for positron identification) and GM-42 high-range GM detector; plus a flow meter
2 referenced values
WebiMissions Software
Rotem

WebiMissions Software

Software for collecting and reporting effluent emissions with existing detectors

Primary function
Collecting, storing, displaying and reporting effluent emissions with existing detectors (derived from WebiSmarts)
Functions
With the PM-11 coincidence system: reports only effluent within the exhaust duct; identifies F-18, Ga-68, O-15, C-11, N-13, I-131, Tc-99m, Ga-67, Tl-201, I-125 and Lu-177
2 referenced values
WebiSmarts System
Rotem

WebiSmarts System

Web-based area and stack monitoring system with DPU-3 monitors

Primary function
Web software that receives online data from DPU-3 area monitors and shows them on colour-coded maps
Functions
One year of history per point; isotope identification of effluent; over 20 maps; real-time background subtraction; dose and dose rate at the same time
System components
Web software, DPU-3 monitors (four detectors each) and a stack monitor; maps, points and history are stored on a server and accessed with a browser
4 referenced values
DPU-3 Meter
Rotem

DPU-3 Meter

Ethernet area monitor with PoE for WebiSmarts, with or without an internal detector

Measurement range
Internal low-range detector: 0.1 µSv/h – 40 mSv/h (0.01 mR/h – 4 R/h); wide-range detector: 0.1 µSv/h – 10 Sv/h (0.01 mR/h – 1,000 R/h)
Detector
One internal and three external detectors, recognised automatically (also available without an internal detector)
Weight
DPU-3: 1.7 kg
11 referenced values
DRM-3000 Meter
Rotem

DRM-3000 Meter

Area monitor for one internal and three external detectors, with 7-inch display

IP rating
IP65 (hardened, high-impact plastic casing)
Weight
1.7 kg
11 referenced values
AlphaE
Bertin

AlphaE

Ultra-small radon meter for concentration, personal exposure and dose

Detector type
Diffusion chamber with silicon diode
Measurement range
20 Bq/m³–10 MBq/m³
Weight
165 g
16 referenced values
Alpha S
Bertin

Alpha S

Portable radon monitor for air, soil and water

Detector type
Pulse ionisation chamber, 0.2 L
Measurement range
Up to 200,000 Bq/m³ (5.4 nCi/L)
Weight
<5.7 kg
12 referenced values
RCP
Bertin

RCP

Radiation portal monitor for pedestrian access control

Detector type
PVT plastic scintillator with large-diameter, low-noise PMT
Energy range
30 keV–5 MeV
10 referenced values
RCCL
Bertin

RCCL

Radiation portal monitor for small containers, luggage and parcels

Detector type
PVT plastic scintillator with large-diameter, low-noise PMT
Energy range
30 keV–5 MeV
8 referenced values
FREE-AND 16
ELSE NUCLEAR

FREE-AND 16

Spectrometric station with 16 NaI(Tl) for waste characterisation

Detector type
16 NaI(Tl) 3 × 3 in crystals with PMT and MCA, eight on each side in two arrays
9 referenced values
AURAS 3000
ELSE NUCLEAR

AURAS 3000

Free-release assay of large waste containers with up to four HPGe

Energy range
HPGe: 30 keV–7 MeV
Energy resolution at 1.33 MeV
HPGe: ≤2.3 keV FWHM for ⁶⁰Co (1332.5 keV)
Relative efficiency
15–150% (nitrogen-cooled), 50–150% (electro-cooled)
13 referenced values
Showing 24 of 69