GM-40 Detector
GM gamma detector for very high fields, 250 µSv/h – 10 Sv/h
- Detector
- GM tube ZP1301
- Measurement range
- 250 µSv/h – 10 Sv/h (25 mR/h – 1,000 R/h)
- Energy range
- 50 keV – 1.3 MeV

Bild: Rotem
Area monitor for one internal and three external detectors, with 7-inch display
Wall or tabletop area monitor that supports one internal and three external detectors, which are identified automatically and can be placed up to 100 yards away. It is powered from AC, PoE or an internal battery, and sends data wirelessly or over Ethernet. The display background colour changes with the radiation level.
Download product sheet (PDF)All values with references – for tender documents
Specifications checked against the manufacturer’s documents on 2026-10-17
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.
| Detector count | 1 internal and 3 external detectors; automatic recognition; cable up to 100 yards1 |
|---|
| Relay outputs | Dry contact to activate external devices1 |
|---|
| Display | 7-inch HD graphic display; background colour shows the dose rate against the thresholds; multicoloured LED1 |
|---|---|
| Communication | TCP/IP, RS-485, Wi-Fi and Xbee; Ethernet directly to a PC or network1 |
| Data storage | Up to one year of data internally1 |
| Power supply | 110 V AC, PoE or internal battery (24 hours)1 |
|---|
| IP rating | IP65 (hardened, high-impact plastic casing)1 |
|---|
| Alarm | High-volume buzzer, 100 dB at 30 cm (optional)2 |
|---|
The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.
The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

GM gamma detector for very high fields, 250 µSv/h – 10 Sv/h

GM gamma detector for high fields, e.g. in cyclotron bunkers and hot cells

Sensitive low-range GM gamma detector for clean rooms and radiopharmacies

Pancake GM probe for alpha, beta and gamma surface contamination

Thin NaI(Tl) probe for low-energy gamma and X-rays, optimised for I-125

Sensitive NaI(Tl) gamma probe, Rotem’s primary effluent detector in WebiSmarts

Detector bracket with LEDs and buzzer for local feedback far from the DPU-3
We help you choose the right configuration, detector and accessories for your measurement task.