bPAD

Digital single-channel analyser (SCA) in the tube socket, controlled via USB

Compact, intelligent single-channel analyser that sits in the photomultiplier tube socket and is set up fully digitally via USB, without an oscilloscope or screwdriver. High voltage, gain and discriminator levels are set in a PC application, which also has a pseudo-PHA mode and shows the count rate in the chosen window.

Weight
Approx. 90 g2
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Differential or integral mode
  • TTL output with programmable pulse duration
  • External 9–36 V supply or via USB
  • Pseudo-PHA in the PC application

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Electronics & signal

DiscriminatorUpper and lower level discriminator, 2,048 steps1
GainCoarse ×1, ×2, ×4, ×8 (optionally also ×16, ×32, ×64, ×128); fine ×1–×2 in 4,096 steps2
Signal outputs5 V TTL, programmable duration 0.25–20 µs in 14 steps (SMA)2
Detector high voltageBuilt-in, 0–1,500 V in 4,096 steps2

Connectivity & interface

CommunicationUSB 2.0 (mini-B), which can also power the device2

Power & battery

Supply voltage9–36 V (pluggable terminal block)2
Power consumptionMax. 1 W2

Mechanical

WeightApprox. 90 g2

Environment & ratings

Operating modesDifferential and integral1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: BrightSpecProduct page Product page – Main features Checked 2026-10-16
  2. 2
    Publisher: BrightSpecDatasheet p. 2, Technical Specifications Checked 2026-10-16
ILLUSTRATION
BrightSpec

bPAD+

bPAD with an extra analogue pulse output to an external MCA

Operating modes
Differential and integral
Discriminator
Upper and lower level discriminator, 2,048 steps
Gain
×1–×256
8 referenced values
bPAD+VR
BrightSpec

bPAD+VR

bPAD+ with an analogue output for pulses or count rate, e.g. for flow instruments

Operating modes
Differential and integral
Discriminator
Upper and lower level discriminator, 2,048 steps
Gain
×1–×16 (×1–×256 on request)
8 referenced values
bPAD 422
BrightSpec

bPAD 422

Digital single-channel analyser in the tube socket with RS422/485, for radiotracer measurements

Weight
Approx. 80 g
8 referenced values
bDAS
BrightSpec

bDAS

Digital acquisition system for synchronised counting with up to 12 probes

Weight
Probe: approx. 4 kg
6 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.