Topaz-Pico BNC

Topaz-Pico with BNC connectors instead of Lemo

Special version of the compact Topaz-Pico multichannel analyser in which the Lemo connectors have been replaced by standard BNC connectors. Otherwise it has the same functions: PHA and MCS, up to 4,096 channels and built-in high voltage for the photomultiplier.

Spectrum channels
Up to 4,0961
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-17

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Digital trapezoidal shaper with BLR and PUR
  • Same software and libraries as the Topaz-Pico

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

ConnectionBNC connectors instead of Lemo1
Acquisition modesPHA (pulse height analysis) and MCS (multichannel scaling)1
Spectrum channelsUp to 4,0961
Gain×1–×161
Detector high voltageUp to 1,500 V1
Dimensions127 × 72 × 19 mm1
CommunicationUSB 2.0 (mini-B), cable included2

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: BrightSpecProduct page Product page; Product page – Main features Checked 2026-10-16
  2. 2
    Publisher: BrightSpecDatasheet Topaz-Pico specification (linked as the full specs from the Topaz-Pico BNC page) – Data communication, Connectors Checked 2026-10-16
Topaz-Pico
BrightSpec

Topaz-Pico

Pocket-size stand-alone digital MCA for scintillation detectors

Spectrum channels
Up to 4,096
Weight
Less than 150 g (including box)
10 referenced values
Flint-NaI-Pro
BrightSpec

Flint-NaI-Pro

Gamma acquisition and analysis bundle: Flint probe with NaI(Tl) and bGamma software

Detector type
Flint: SiPM-based integrated probe with a NaI crystal, 2 × 2 or 3 × 3 in
Spectrum channels
256, 512, 1,024, 2,048 or 4,096, 32-bit depth per channel
10 referenced values
bSCAN
BrightSpec

bSCAN

Radio-TLC scanner with NaI(Tl) detector and built-in MCA

Detector type
NaI(Tl), typically 1 × 1 in (2.54 × 2.54 cm)
Spectrum channels
Up to 4,096 (PHA and MCS)
Weight
16.5 kg (36.4 lb)
12 referenced values
NewFlint USB
BrightSpec

Flint USB

Integrated gamma probe: SiPM scintillation detector and digital MCA in one housing

Detector type
Scintillator with SiPM; standard round NaI(Tl), 2 × 2 or 3 × 3 in; can be ordered with CsI(Tl), CeBr₃, LaBr₃(Ce), LBC or SrI₂
Spectrum channels
256, 512, 1,024, 2,048 or 4,096, 32-bit depth per channel
13 referenced values