PARSTAT 3000A-DX bipotentiostat

Bipotentiostat

Two synchronized potentiostats in one compact instrument for rotating ring-disk electrodes and catalyst studies.

Measurement channels
2 independent potentiostats1
Compliance voltage
Channel 1: ±12 V; channel 2: ±30 V2

Specifications checked against the manufacturer’s documents on 2026-10-16

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Two complete potentiostat channels.
  • Hardware synchronization between channels.
  • Suited to RRDE and fuel-cell catalyst studies.

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Measuring range

Polarization voltageChannel 1: ±10 V; channel 2: ±30 V2
EIS frequency rangeChannel 1: 10 µHz–1 MHz; channel 2: 10 µHz–7 MHz; included2
Minimum current range, standard4 nA on both channels2

Electronics & signal

Measurement channels2 independent potentiostats1
Maximum output currentChannel 1: 2 A; channel 2: 1 A2

Software & data

SoftwareVersaStudio included1

Connectivity & interface

Cell connections6-wire capability on channel 2; unavailable on channel 12

Environment & ratings

Compliance voltageChannel 1: ±12 V; channel 2: ±30 V2

Ordering & accessories

Low-current optionVersaSTAT-LC on channel 1: 4 pA range2

General

Maximum data acquisition rateChannel 1: 500 kS/s; channel 2: 1 MS/s2
Floating measurement / isolationBoth channels: floating or grounded2
SynchronizationHardware-synchronized start in bipotentiostat mode2

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: AMETEK Scientific InstrumentsProduct page product page Checked 2026-10-16
  2. 2
    Publisher: AMETEK Scientific InstrumentsDatasheet p. 4, tables "PARSTAT 3000A-DX channel 1" and "channel 2"; p. 4 Checked 2026-10-16
ModuLab XM MTS materialtestsystem
AMETEK SI

ModuLab XM MTS materialtestsystem

Materials test system

Impedance range
10 µΩ–100 TΩ depending on module configuration
EIS frequency range
10 µHz–1 MHz with XM MFRA 1MHz
Maximum output current
XM MAT: ±100 mA; XM MBST 2A: ±2 A (option)
6 models
ModuLab XM ECS
AMETEK SI

ModuLab XM ECS

Configurable electrochemical system

Compliance voltage
±8 V standard; ±30 V / ±100 V with HV options
8 models
PARSTAT MC
AMETEK SI

PARSTAT MC

Modular multichannel system

Measurement channels
Up to 20 with PMC-200; up to 10 with PMC-1000 or PMC-2000A
Compliance voltage
PMC-200: ±10 V; PMC-1000: ±12 V; PMC-2000A: ±30 V
3 models
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.