P Series (P100)

Collimated gamma imager

An imaging spectrometer that focuses on a weak source next to stronger gamma radiation.

Detector type
P100/P100S: CZT (CdZnTe)1
Spectroscopy energy range
P100/P100S: 50–3000 keV2
Weight
P100/P100S: 25 lb (approximately 11.3 kg)1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-10-16

Manufacturer’s product page (opens in a new tab)

Overview

Key features

  • Tungsten collimator limits measurements to the selected direction.
  • P100 provides spectroscopy, identification and imaging; P100S is spectroscopy-only.
  • For waste characterization, pipes and response measurements.

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

Detector

Detector typeP100/P100S: CZT (CdZnTe)1
Detector volumeP100: >6 cm³; P100S: >4.5 cm³2

Performance

Energy resolution at 662 keV≤1.1% FWHM (coincident interactions combined); ≤0.9% FWHM (separated)1

Measuring range

Spectroscopy energy rangeP100/P100S: 50–3000 keV2
Imaging energy rangeP100: 250–3000 keV; P100S: no imaging2

Connectivity & interface

User interfaceP100: tablet; P100S: tablet/webpage2
CommunicationP100: Wi-Fi, Bluetooth or wired tablet connection; Ethernet RJ45, TCP/IP1

Power & battery

Battery lifeP100/P100S: >7 hours at 23 °C; >3 hours at −20 °C or +50 °C1
Power supplyP100: 100–240 V, 47–63 Hz1

Mechanical

WeightP100/P100S: 25 lb (approximately 11.3 kg)1
DimensionsP100: 22.6 × 12.4 × 16 cm1

Environment & ratings

IP ratingP100/P100S: IP65 with fan replacement1

General

CollimatorP100/P100S: 1 in (2.54 cm) tungsten, with removable plug3

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: H3DDatasheet P100 sheet p. 2 'Crystal Volume'; p. 2 'Weight' (same in P100S sheet); p. 2 'Battery Life' – identical in the P100 and P100S sheets; p. 2 'Ingress Protection' – identical in the P100 and P100S sheets … Checked 2026-10-16
  2. 2
    Publisher: H3DProduct page p100.php model table, row 'CZT Volume (cm3)' (columns P100, P100S); p100.php model table, row 'Spectrometer Range (keV)'; p100.php model table, row 'Imaging Range (keV)'; p100.php model table, row 'User Interface' Checked 2026-10-16
  3. 3
    Publisher: H3DDatasheet p. 2 'Collimator Thickness' – identical in the P100 (S13) and P100S (S14) sheets Checked 2026-10-16
H Series
H3D

H Series

Gamma imaging

Detector type
CZT (CdZnTe)
Spectroscopy energy range
50–3000 keV (H100/H400/H420/H1600)
IP rating
H100/H400/H420/H1600: IP67 (excluding external media)
9 models
A Series (A400) RIID
H3D

A Series (A400) RIID

Handheld RIID

Detector type
A400: CZT (CdZnTe)
Spectroscopy energy range
A400: 50–3000 keV
Weight
A400: 1.2 kg
6 models
GammAware 3D Radiation Imaging
H3D

GammAware 3D Radiation Imaging

3D radiation mapping

Mapping method
SLAM, simultaneous localization and mapping
Compatibility
H Series (e.g. H100/H400/H420) and M Series (e.g. M100/M400)
Visualization
Radiation hotspots overlaid on the scanned area’s 3D model
16 referenced values
T Series (T410)
H3D

T Series (T410)

Rugged integrable gamma imager

Detector type
T Series: CZT (CdZnTe)
Spectroscopy energy range
All tabulated T400S/T410 variants: 50–3000 keV
Weight
T410/T400S (including +): 8.7 lb; T410P/T410SP (including +): 10.9 lb
13 referenced values
Contact us

Questions about this product?

We help you choose the right configuration, detector and accessories for your measurement task.