Meter
Model 3002 Alpha-Beta Survey Meter1
Detector height above the floor
Adjustable from 0 to 16 mm1
Temperature range
-20 to 50 °C1
Datasheet

Specifications checked against the manufacturer’s documents on 2026-11-17

Manufacturer’s product page (opens in a new tab)

Already have the instrument? Request service or support →

Overview

Key features

  • Simultaneous alpha-beta counting
  • Gasless design with scintillators
  • Dual-tone audio for alpha and beta
  • Detector height easily adjusted above the floor

Specifications

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

MeterModel 3002 Alpha-Beta Survey Meter1
Detector height above the floorAdjustable from 0 to 16 mm1
Temperature range-20 to 50 °C1

The data comes from the manufacturer’s published documents. Manufacturers may change specifications; the current configuration and performance are confirmed in the quotation.

Models

3 models in the series. Filter or scroll the table to compare.

3 / 3
ModelPart number1Detectors1Active area1Total window width1Detection efficiency (4π)1Dimensions1Weight1
3002/FM148-4037-12 ea. Model 43-147 alpha-beta scintillation detectorsActive 400 cm², open 352 cm²22.4 cmPu-239 20%, Tc-99 15%, Sr-90/Y-90 20%76 x 40 x 137 cm (H x W x L)5 kg
3002/FM248-4037-22 ea. Model 43-147 alpha-beta scintillation detectorsActive 400 cm², open 352 cm²40.9 cmPu-239 20%, Tc-99 15%, Sr-90/Y-90 20%76 x 60 x 137 cm (H x W x L)5.6 kg
3002/FM348-4037-32 ea. Model 43-204-2 alpha-beta scintillation detectorsActive 1080 cm², open 960 cm²65.7 cmPu-239 18%, Tc-99 10%76 x 86 x 154 cm (H x W x L)11.2 kg

Documents

Sources

The number after each value refers to the source listed below. Values are as published by the manufacturer; the exact configuration is always confirmed in our quotation.

  1. 1
    Publisher: Ludlum MeasurementsProduct page Specifications – Meter; Specifications – Detector Height; Specifications – Temperature Range; Specifications – Part Number … Checked 2026-11-17
Model 43-37 Series
Ludlum

Model 43-37 Series

Gas proportional detector for floor surveying

Detector type
Large-area gas proportional
2 models
Model 26 Friskers
Ludlum

Model 26 Friskers

Contamination monitoring

Detector type
Integrated pancake GM
Energy range
16.3 keV–1.3 MeV
Count-rate range
0.1 cps–1.99 kcps; 1 cpm–99.9 kcpm
12 referenced values
RDS SABG Probe
Ludlum

RDS SABG Probe

GM pancake probe for contamination monitoring

Detector type
Geiger-Mueller pancake tube
Energy range
Beta 100 keV – 5 MeV
Count-rate range
0–1.5 Mcpm
15 referenced values
RDS Alpha-Beta Probe
Ludlum

RDS Alpha-Beta Probe

Alpha/beta probe for surface contamination

Active area
100 cm²
Energy range
Alpha 3–8 MeV
Count-rate range
0–1.5 Mcpm
16 referenced values